{"product_id":"omron-zx-lda11-zx-series-amplifier-unit","title":"Omron ZX-LDA11 ZX Series Amplifier Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegrating high-speed resolution and flexible configuration into industrial measurement networks, the \u003cstrong\u003eZX-LDA11\u003c\/strong\u003e functions as a high-performance \u003cstrong\u003eNPN amplifier unit\u003c\/strong\u003e within the Omron ZX series platform. This sensor amplifier provides the signal processing required for displacement and measurement applications, executing rapid sampling and linear signal conversion from connected sensor heads. It bridges the raw physical measurements from optical and inductive heads to standard control systems like PLCs and dedicated positioning modules.\u003c\/p\u003e\n\n\u003cp\u003eBuilt for precise industrial inspection environments, the device features robust analog outputs—both current and voltage—alongside configurable digital averaging to optimize measurement stability under varying conditions. The module is fully compatible with both reflective and through-beam ZX-series sensor heads, enabling precision positioning, thickness measurement, and surface profile analysis across automated production lines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Response:\u003c\/strong\u003e Features a rapid sampling period of 150 microseconds for dynamic real-time tracking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Linear Outputs:\u003c\/strong\u003e Supports simultaneous current (4 to 20 mA) and voltage (±4 V, ±5 V, or 1 to 5 V) outputs for flexible system integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable Averaging:\u003c\/strong\u003e Integrated digital filter supports average count settings from 1 to 4,096 cycles to suppress environmental noise.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNPN Output Logic:\u003c\/strong\u003e Engineered for seamless interface with standard NPN-compatible industrial input modules and controllers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Build:\u003c\/strong\u003e Constructed with a durable polybutylene terephthalate (PBT) case and a polycarbonate cover to withstand demanding industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePrecision electronic component positioning and height measurement.\u003c\/li\u003e\n  \u003cli\u003eSheet thickness monitoring in metalworking and plastics extrusion.\u003c\/li\u003e\n  \u003cli\u003eSurface flatness and profile inspections in automotive assembly.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed packaging and sorting alignment control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZX-LDA11\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eZX Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAmplifier Unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNPN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 to 24 VDC ±10% (Ripple p-p: 10% max.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e140 mA max. (at 24 VDC with sensor head connected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSampling Period\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150 microseconds (us)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Count Settings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, or 4096\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Output (Current)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 to 20 mA \/ Full Scale (Max. load resistance: 300 Ohm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Output (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e±4 V, ±5 V, 1 to 5 V (Output impedance: 100 Ohm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature Characteristic (Reflective)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.01% FS\/degC (when connected to Reflective Sensor Head)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature Characteristic (Through-beam)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.1% FS\/degC (when connected to Through-beam Sensor Head)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 50 degC (with no icing or condensation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-15 to 60 degC (with no icing or condensation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating\/Storage Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35% to 85% RH (with no condensation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 MOhm min. at 500 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,000 VAC, 50\/60 Hz for 1 minute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePrewired (Standard cable length: 2 m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaterial Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCase: PBT (polybutylene terephthalate), Cover: Polycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 0.35 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount on a standard 35mm DIN rail within a clean, vibration-free electrical enclosure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Isolation:\u003c\/strong\u003e Route the 2m pre-wired cable away from high-voltage lines, power cables, and motor drive leads to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the mounting rail and the sensor head shield are securely grounded to a single point to ensure measurement accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Controls:\u003c\/strong\u003e Avoid installation in environments with direct exposure to water, oil, or corrosive gases, and ensure ambient temperatures remain between 0 and 50 degC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077917892971,"sku":"ZX-LDA11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ZX-LDA11-hfujgf1wx3i.png?v=1775734105","url":"https:\/\/www.plcprotech.com\/fa\/products\/omron-zx-lda11-zx-series-amplifier-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}