{"product_id":"schneider-altistart-48-ats48d47y-soft-starter","title":"استارتر نرم اشنایدر آلت استارت 48 ATS48D47Y","description":"\u003cp\u003eDescription\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS48D47Y\u003c\/strong\u003e is a \u003cstrong\u003eSoft Starter\u003c\/strong\u003e from the \u003cstrong\u003eAltistart 48\u003c\/strong\u003e series, engineered by \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e to provide smooth starting and stopping for 3-phase asynchronous motors. This unit is rated for a nominal current of 40A and supports a wide input voltage range from 208V to 690V. With a power capacity ranging from 11KW to 37KW, the \u003cstrong\u003eATS48D47Y\u003c\/strong\u003e utilizes torque control technology to reduce mechanical stress on driven equipment, such as belts, gears, and pump couplings. Its robust design is well-suited for heavy-duty industrial applications, offering controlled acceleration and deceleration to optimize motor performance and system longevity.\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal current: 40A\u003c\/li\u003e\n\u003cli\u003eVoltage range: 208 - 690V (3-phase)\u003c\/li\u003e\n\u003cli\u003ePower range: 11 - 37KW\u003c\/li\u003e\n\u003cli\u003eTorque control technology for smooth acceleration\/deceleration\u003c\/li\u003e\n\u003cli\u003eDesigned for 3-phase asynchronous motor protection and control\u003c\/li\u003e\n\u003cli\u003eRobust build for demanding industrial motor applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal and piston pumps\u003c\/li\u003e\n\u003cli\u003eFans and high-inertia blowers\u003c\/li\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eConveyor systems\u003c\/li\u003e\n\u003cli\u003eIndustrial mixers and crushers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical Specifications\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATS48D47Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e208 - 690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e11 - 37KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.19kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e37 x 26 x 29 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLM Product Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eInstallation Guidelines\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the soft starter vertically in a ventilated cabinet to ensure effective thermal dissipation during operation.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate clearance above and below the unit to allow for heat exhaust and maintenance access.\u003c\/li\u003e\n\u003cli\u003eConnect the power supply and motor terminals according to the wiring diagram, ensuring correct phase sequence.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for control signals to minimize electromagnetic interference from power lines.\u003c\/li\u003e\n\u003cli\u003eVerify that the motor nameplate parameters match the configured settings in the starter's control menu.\u003c\/li\u003e\n\u003cli\u003eCheck that all power connections are torqued to the manufacturer’s specification to ensure electrical integrity and prevent hot spots.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104564339051,"sku":"ATS48D47Y","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats48d47y-bcgdcn1xba3.png?v=1776162123","url":"https:\/\/www.plcprotech.com\/fa\/products\/schneider-altistart-48-ats48d47y-soft-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}