{"product_id":"schneider-electric-altistart-46-ats46m10n-soft-starter","title":"Schneider Electric Altistart 46 ATS46M10N Soft Starter","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS46M10N\u003c\/strong\u003e is a high-capacity \u003cstrong\u003eAltistart 46 soft starter\u003c\/strong\u003e designed for large-scale industrial motor control applications. Capable of handling a nominal current of 1000 A, this unit provides controlled acceleration and deceleration for three-phase asynchronous motors. By regulating the voltage applied to the motor, the \u003cstrong\u003eATS46M10N\u003c\/strong\u003e minimizes mechanical shocks to drive trains and reduces excessive inrush current, thereby extending the operational lifespan of both the motor and associated mechanical equipment. This model represents the robust, reliable engineering typical of the Altistart 46 range, optimized for high-power demands.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Controlled starting and stopping for high-power three-phase motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 1000 A nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance:\u003c\/strong\u003e Reduces inrush current and mechanical stress\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication-Specific:\u003c\/strong\u003e Ideal for high-inertia loads and heavy-duty industrial machinery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Robust design for industrial integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-scale pump and fan systems\u003c\/li\u003e\n\u003cli\u003eIndustrial centrifugal compressors\u003c\/li\u003e\n\u003cli\u003eHigh-inertia conveyer systems\u003c\/li\u003e\n\u003cli\u003eHeavy-duty manufacturing crushers and mills\u003c\/li\u003e\n\u003cli\u003eLarge ventilation and air extraction systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Current\u003c\/td\u003e\n\u003ctd\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e45.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Due to the weight of 45 kg, ensure the mounting structure is reinforced and capable of supporting the unit securely. Install vertically in a well-ventilated enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain an operating environment free from conductive dust, moisture, and extreme temperatures. Adequate cooling air circulation is vital for high-current components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use busbars or large-gauge cables rated for 1000 A. Ensure all termination points are tightened according to the technical documentation to prevent localized heating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Always disconnect all power sources before inspection or maintenance. Ensure the unit is properly grounded to a main system earth bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration:\u003c\/strong\u003e Verify that the supply mains are capable of supporting the required starting current profiles before commissioning the drive.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104560374123,"sku":"ATS46M10N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats46m10n-x5t3jkccj2k.png?v=1776162091","url":"https:\/\/www.plcprotech.com\/fa\/products\/schneider-electric-altistart-46-ats46m10n-soft-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}