{"product_id":"siemens-6av7725-2aa10-0ad0-simatic-panel-pc-670","title":"Siemens 6AV7725-2AA10-0AD0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis Siemens 6AV7725-2AA10-0AD0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. It features a \u003cstrong\u003e15.1-inch color TFT display\u003c\/strong\u003e for clear process visualization and operator interaction. The system is powered by a \u003cstrong\u003eCeleron 1.2 GHz processor\u003c\/strong\u003e and is equipped with \u003cstrong\u003e256 MB of SDRAM\u003c\/strong\u003e, providing reliable performance for standard automation tasks. With a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e and an integrated DVD-ROM, this panel PC supports local data storage and software installation. The unit operates on a \u003cstrong\u003e24V DC power supply\u003c\/strong\u003e, making it suitable for direct integration into industrial control cabinets and machinery.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e15.1-inch Color TFT Display\u003c\/li\u003e\n  \u003cli\u003eCeleron 1.2 GHz Processor\u003c\/li\u003e\n  \u003cli\u003e256 MB SDRAM-133 Memory (1x256MB)\u003c\/li\u003e\n  \u003cli\u003e40 GB EIDE Hard Disk Drive\u003c\/li\u003e\n  \u003cli\u003eIntegrated DVD-ROM Drive\u003c\/li\u003e\n  \u003cli\u003e24V DC Power Input\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows 2000 Multi Language\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMachine-level operator control and monitoring\u003c\/li\u003e\n  \u003cli\u003eProcess visualization (SCADA\/HMI)\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging\u003c\/li\u003e\n  \u003cli\u003eManufacturing Execution Systems (MES) terminals\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6AV7725-2AA10-0AD0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIndustrial Panel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e15.1-inch Color TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCeleron 1.2 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e256 MB SDRAM-133 (1x256MB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e40 GB EIDE Hard Drive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDVD-ROM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e24V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWindows 2000 Multi Language\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e48.00 x 29.00 x 15.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Installation must be performed by qualified personnel only. Failure to adhere to safety procedures can result in equipment damage, serious injury, or death. Always de-energize and lock-out\/tag-out (LOTO) all power sources before installation or maintenance. Use appropriate personal protective equipment (PPE) and electrostatic discharge (ESD) protection.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003ePanel Cutout and Mounting:\u003c\/strong\u003e Prepare the control cabinet panel cutout according to the manufacturer's dimensional drawings. Ensure the mounting surface is clean, flat, and rigid. Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps to maintain the specified ingress protection rating. Do not overtighten the clamps.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect the chassis ground terminal to the control cabinet's main protective earth busbar using a low-impedance conductor. A secure and reliable ground connection is critical for safety and noise immunity.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003ePower Supply Connection:\u003c\/strong\u003e Connect a stable, filtered 24V DC power source to the designated power input terminals. Verify the correct polarity (+\/-) before applying power. Use appropriately sized conductors and ensure connections are torqued to specification. It is recommended to use a dedicated, isolated power supply unit (PSU) for the Panel PC.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eInterface Cabling:\u003c\/strong\u003e Connect all required communication and peripheral cables (e.g., Ethernet, USB, serial). Route cables away from high-voltage lines and sources of electromagnetic interference (EMI) such as VFDs and motor contactors. Use shielded cables where specified and ensure shields are properly terminated.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eInitial Power-Up:\u003c\/strong\u003e After verifying all connections, remove the LOTO and apply power to the unit. Observe the boot sequence to ensure the operating system loads correctly. Proceed with software configuration and network setup as required by the application.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715876614507,"sku":"6AV7725-2AA10-0AD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7725-2aa10-0ad0-kzpktfsrblj_c7dbfaa5-1971-4cd2-8e29-68efd987eb71.jpg?v=1767073473","url":"https:\/\/www.plcprotech.com\/fa\/products\/siemens-6av7725-2aa10-0ad0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}