{"product_id":"siemens-6av7725-2bc10-0ag0-simatic-panel-pc-670","title":"Siemens 6AV7725-2BC10-0AG0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7725-2BC10-0AG0 is a SIMATIC Panel PC 670, a robust industrial computer designed for human-machine interface (HMI) and visualization tasks in demanding environments. This standard configuration unit is equipped with a \u003cstrong\u003e15.1-inch color TFT display\u003c\/strong\u003e, a \u003cstrong\u003ePentium III 1.26 GHz\u003c\/strong\u003e processor, and \u003cstrong\u003e256 MB of SDRAM\u003c\/strong\u003e. It includes a \u003cstrong\u003e40 GB EIDE hard drive\u003c\/strong\u003e, a DVD-ROM drive, and comes pre-installed with the Windows XP Professional operating system, supporting multiple languages. The integrated power supply is rated for \u003cstrong\u003e115-230V AC\u003c\/strong\u003e input.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003e15.1-inch color TFT display for clear process visualization.\u003c\/li\u003e\n\u003cli\u003eIntel Pentium III processor operating at 1.26 GHz.\u003c\/li\u003e\n\u003cli\u003e256 MB SDRAM-133 system memory.\u003c\/li\u003e\n\u003cli\u003e40 GB EIDE hard disk drive for application and data storage.\u003c\/li\u003e\n\u003cli\u003eIntegrated DVD-ROM optical drive.\u003c\/li\u003e\n\u003cli\u003ePre-installed with Windows XP Professional (Multi-Language).\u003c\/li\u003e\n\u003cli\u003eWide-range power supply: 115-230V AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eMachine-level HMI and control\u003c\/li\u003e\n\u003cli\u003eProcess visualization and data logging\u003c\/li\u003e\n\u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n\u003cli\u003eManufacturing Execution Systems (MES) terminals\u003c\/li\u003e\n\u003cli\u003eIndustrial automation control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePentium III, 1.26 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e256 MB SDRAM-133 (1 x 256MB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e15.1-inch Color TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e40 GB HDD EIDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDVD-ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eWindows XP Professional (Multi-Language)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e115-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003e12.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0; background-color: #fdfdfe;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e48.0 x 29.0 x 15.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect and lock out all power sources before installation or servicing. Installation must be performed by qualified personnel familiar with industrial control panel standards and practices. Failure to de-energize equipment can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n\u003cspan\u003ePrepare the panel cutout according to the device's mechanical specifications. Ensure the mounting surface is clean, flat, and can support the weight of the unit (12.00 kg).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n\u003cspan\u003eInsert the Panel PC into the cutout from the front. Secure it using the provided mounting clamps, tightening them evenly to the manufacturer's recommended torque to ensure a proper seal.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n\u003cspan\u003eConnect the protective earth (PE) conductor to the designated grounding terminal on the chassis. A low-impedance ground connection is essential for safety and noise immunity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n\u003cspan\u003eConnect the AC power supply using the provided mains cable to a properly rated and protected circuit. Ensure the source voltage (115-230V AC) matches the equipment's rating.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n\u003cspan\u003eConnect all required communication and I\/O cables. Route cables to prevent strain and interference. Use shielded cables for communication lines and ground the shields appropriately.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px;\"\u003e6\u003c\/span\u003e\n\u003cspan\u003eAfter verifying all connections are secure and correct, remove the lockout\/tagout device and restore power to the unit for commissioning.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715872551275,"sku":"6AV7725-2BC10-0AG0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7725-2bc10-0ag0-2y4xbbr1chf_f581ae9d-7878-475a-8c1d-9079ea1987de.jpg?v=1767073436","url":"https:\/\/www.plcprotech.com\/fa\/products\/siemens-6av7725-2bc10-0ag0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}