{"product_id":"siemens-6av7873-0bf32-1ac0-simatic-panel-pc-677b","title":"Siemens 6AV7873-0BF32-1AC0 SIMATIC Panel PC 677B","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6AV7873-0BF32-1AC0 SIMATIC Panel PC 677B, an integrated human-machine interface (HMI) designed for demanding industrial environments. It features a \u003cstrong\u003e15-inch keypad display\u003c\/strong\u003e with a 1024x768 resolution and is powered by an Intel \u003cstrong\u003eCore 2 Duo T7400\u003c\/strong\u003e processor. The system is configured with \u003cstrong\u003e2 GB of DDR2 RAM\u003c\/strong\u003e and a \u003cstrong\u003eRAID1 array\u003c\/strong\u003e of two 250 GB SATA hard drives for data redundancy. Connectivity options include dual Gigabit Ethernet ports, multiple USB 2.0 ports, a serial port, and an integrated \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e. This unit is pre-installed with Windows XP Professional and is powered by a 110\/230 V AC supply.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003e15-inch display with integrated keypad for operator input.\u003c\/li\u003e\n  \u003cli\u003eIntel Core 2 Duo T7400 processor running at 2.16 GHz.\u003c\/li\u003e\n  \u003cli\u003eRedundant storage with a RAID1 configuration of two 250 GB SATA hard drives.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFIBUS\/MPI interface with 2 MB buffered SRAM.\u003c\/li\u003e\n  \u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports for network connectivity.\u003c\/li\u003e\n  \u003cli\u003eFront-side USB port for convenient access.\u003c\/li\u003e\n  \u003cli\u003eExpansion capabilities with one PCI and one PCIe x4 slot.\u003c\/li\u003e\n  \u003cli\u003eIncludes a DVD+-R+-RW optical drive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eProcess visualization and control (SCADA\/HMI).\u003c\/li\u003e\n  \u003cli\u003eMachine-level data acquisition and monitoring.\u003c\/li\u003e\n  \u003cli\u003eIndustrial control room operator stations.\u003c\/li\u003e\n  \u003cli\u003eManufacturing Execution Systems (MES) terminals.\u003c\/li\u003e\n  \u003cli\u003eFactory automation and plant management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC Panel PC 677B\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6AV7873-0BF32-1AC0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e15-inch with Keypad\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIntel Core 2 Duo T7400, 2.16 GHz, 4 MB SLC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 GB DDR2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRAID1, 2x 250 GB SATA (2.5-inch)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDVD+-R+-RW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e110\/230 V AC with NAMUR\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4x USB 2.0, 1x Front-side USB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1x COM1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePROFIBUS\/MPI, 2 MB Buffered SRAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1x PCI, 1x PCIe x4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows XP Professional MUI (Multi-Language)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e17.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e67.0 x 83.0 x 11.5 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cp style=\"margin: 0; color: #c53030;\"\u003e\u003cstrong\u003eCRITICAL WARNING: Hazardous voltages are present. Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before installation or maintenance to prevent electric shock and equipment damage.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePanel Preparation:\u003c\/strong\u003e Ensure the control cabinet or panel cutout dimensions match the PC's mounting specifications. Verify that the mounting surface is flat, clean, and can support the unit's weight (17.00 kg).\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely fasten the Panel PC into the cutout using all provided mounting clamps. Tighten clamps evenly to ensure a proper seal and prevent chassis distortion.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the PC chassis. This is critical for both safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 110\/230 V AC power supply using the provided cable. Ensure the source voltage matches the unit's rating and is stable. Use a dedicated, circuit-breaker-protected power source.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eI\/O Connections:\u003c\/strong\u003e Connect Ethernet, PROFIBUS, USB, and serial cables as required. Route communication cables separately from high-voltage power lines to minimize electromagnetic interference (EMI).\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715866947947,"sku":"6AV7873-0BF32-1AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7873-0bf32-1ac0-mfucgrao2fy_c7606156-05fd-47ee-a93f-020f605b348e.jpg?v=1767073246","url":"https:\/\/www.plcprotech.com\/fa\/products\/siemens-6av7873-0bf32-1ac0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}