{"product_id":"siemens-6es7134-4gb11-0ab0-simatic-et-200s-analog-input-module","title":"Siemens 6ES7134-4GB11-0AB0 SIMATIC ET 200S Analog Input Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThis is a Siemens 6ES7134-4GB11-0AB0 analog input module for the SIMATIC ET 200S distributed I\/O system. It provides \u003cstrong\u003etwo isolated current input channels\u003c\/strong\u003e specifically designed for connecting \u003cstrong\u003e4-wire transmitters\u003c\/strong\u003e. With a compact \u003cstrong\u003e15 mm width\u003c\/strong\u003e, this module optimizes cabinet space while delivering precise data acquisition. It supports multiple measurement ranges, including \u003cstrong\u003e±20 mA\u003c\/strong\u003e with 13 bits plus sign resolution and \u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e with 13-bit resolution, making it suitable for critical process monitoring in various industrial automation environments.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe module ensures high signal integrity through sophisticated noise suppression, achieving a minimum of 70 dB common-mode rejection. Its robust design and diagnostic capabilities, indicated by an integrated SF (System Fault) LED, provide reliable performance for demanding applications requiring accurate current signal acquisition.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eTwo isolated analog current input channels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eDesigned for 4-wire current transmitters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eHigh resolution of 13 bits (+ sign for ±20 mA range)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eCompact 15 mm width for high-density mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIntegrated SF (System Fault) LED for onboard diagnostics\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eExcellent noise suppression and high repeatability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eProcess control systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eFactory automation and manufacturing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eWater and wastewater treatment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eEnergy monitoring and management\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6ES7134-4GB11-0AB0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Family\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC ET 200S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eAnalog Input Module (2AI I 4WIRE ST)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eNumber of Inputs\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2, isolated\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eInput Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCurrent, for 4-wire transmitters\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMeasurement Range\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e±20 mA; 4 to 20 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e13 bits + sign (for ±20 mA); 13 bits (for 4 to 20 mA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBasic Error Limit (at 25 degC)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e±0.4%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperational Error Limit\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e±0.6% (over full temperature range)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eTemperature Error\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e±0.005%\/K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRepeatability (steady-state)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e±0.05%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommon-Mode Rejection (min)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e70 dB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCrosstalk Suppression\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e-50 dB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCycle Time per Channel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e65 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating Temperature (Vertical)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0 to 50 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModule Width\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDiagnostics\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSF (System Fault) LED\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0.95 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out\/tagged out (LOTO) before commencing work. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eMount the module onto the corresponding ET 200S terminal module on a standard 35mm DIN rail. Ensure it is securely seated to establish a proper backplane bus connection.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eConnect the 4-wire transmitter signal wiring to the designated terminals on the terminal module. Use shielded, twisted-pair cable for all analog signal runs to minimize electromagnetic interference (EMI).\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eTerminate the cable shield at a single, dedicated low-impedance earth ground point, typically at the control cabinet's ground bar. Avoid creating ground loops by connecting the shield at both ends.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eEnsure proper cable management, separating analog signal cables from high-voltage power lines to prevent induced noise. Secure all wiring according to local electrical codes.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eAfter all connections are verified, remove the LOTO device and apply power to the system. Check the module's status LEDs for normal operation and configure the input channels in the PLC programming software.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695210688875,"sku":"6ES7134-4GB11-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es7134-4gb11-0ab0-analog-input-module-iozduaif4ft_23236984-7603-4b9e-b09c-00b77dbcef18.jpg?v=1766130820","url":"https:\/\/www.plcprotech.com\/fa\/products\/siemens-6es7134-4gb11-0ab0-simatic-et-200s-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}