{"product_id":"siemens-6es7148-1fa00-0xb0-simatic-et-200x-em148-fc-frequency-converter","title":"Siemens 6ES7148-1FA00-0XB0 SIMATIC ET 200X EM148-FC Frequency Converter","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6ES7148-1FA00-0XB0 EM148-FC frequency converter, a component of the SIMATIC ET 200X distributed I\/O system. Designed for cabinet-free, machine-mounted applications, this module provides a power output of \u003cstrong\u003e750W\u003c\/strong\u003e and features an integrated network filter. It is built for robust industrial environments with an \u003cstrong\u003eIP65\u003c\/strong\u003e degree of protection and utilizes the DESINA standard for connections. This specific part number is classified as obsolete, with a designated successor available.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e750W power rating for motor control.\u003c\/li\u003e\n  \u003cli\u003eIntegrated network filter to reduce electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eIP65 degree of protection, suitable for direct machine mounting without a control cabinet.\u003c\/li\u003e\n  \u003cli\u003eConnection interface compliant with the DESINA standard.\u003c\/li\u003e\n  \u003cli\u003ePart of the SIMATIC DP distributed I\/O family for seamless integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eDecentralized drive solutions in manufacturing and logistics.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and material handling equipment.\u003c\/li\u003e\n  \u003cli\u003ePackaging and processing machinery.\u003c\/li\u003e\n  \u003cli\u003eAutomotive production lines.\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring high protection against dust and water ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e6ES7148-1FA00-0XB0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Family\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC ET 200X\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eEM148-FC Frequency Converter\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e750 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDegree of Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eIP65\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eNetwork Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC DP (PROFIBUS DP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSuccessor Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e6ES7148-1FA10-0XB0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e4.04 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (L x W x H)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e24.00 x 16.50 x 15.50 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: RISK OF ELECTRIC SHOCK\u003c\/p\u003e\n  \u003cp style=\"color: #2d3748; margin-bottom: 0;\"\u003eThis equipment contains hazardous voltages that can cause severe injury or death. All installation, commissioning, and maintenance activities must be performed by qualified personnel who are trained in handling high-voltage industrial equipment. Always follow local safety regulations and Lockout\/Tagout (LOTO) procedures before accessing any terminals or connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before beginning installation, completely disconnect and lock out all incoming power sources to the module and associated machinery according to established LOTO procedures. Verify the absence of voltage with a properly rated test instrument.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Mount the frequency converter directly onto a solid, flat, and vibration-free machine surface. Ensure adequate clearance around the unit for air circulation and heat dissipation. Use all provided mounting points with the correct size and grade of hardware.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eConnect Power and Motor:\u003c\/strong\u003e Connect the main power supply and motor cables using DESINA-compliant, IP65-rated connectors. Ensure that all connectors are fully seated and locked to maintain the environmental seal. Verify correct phasing for motor connections.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eEstablish Communication:\u003c\/strong\u003e Connect the SIMATIC DP (PROFIBUS) communication cable to the designated port. Use appropriate shielded cabling and ensure the network bus is properly terminated according to PROFIBUS specifications.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eFinal System Check:\u003c\/strong\u003e Double-check all electrical and communication connections for tightness and correctness. Ensure all protective covers and cable glands are properly installed and sealed. Once the installation is verified, remove LOTO devices and proceed with system commissioning.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716781240683,"sku":"6ES7148-1FA00-0XB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7148-1fa00-0xb0-4pqw3wlqirj_3f945dce-e0c8-41d1-824f-07a1325f0acb.jpg?v=1767089548","url":"https:\/\/www.plcprotech.com\/fa\/products\/siemens-6es7148-1fa00-0xb0-simatic-et-200x-em148-fc-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}