{"product_id":"siemens-6gt2002-2ce00-moby-i-asm424-communication-module","title":"ماژول ارتباطی MOBY I ASM424 زیمنس 6GT2002-2CE00  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GT2002-2CE00\u003c\/strong\u003e is a \u003cstrong\u003eMOBY I\u003c\/strong\u003e communication module, specifically the \u003cstrong\u003eASM424\u003c\/strong\u003e variant, designed to interface identification systems with host controllers. This module facilitates data exchange between \u003cstrong\u003eMOBY I\u003c\/strong\u003e read\/write devices and external systems using a serial interface that supports both RS-232 and RS-422 standards. It implements the 3964R transmission procedure, ensuring reliable communication with PCs, SICOMP systems, and third-party controllers.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GT2002-2CE00\u003c\/strong\u003e is engineered for efficiency, allowing for the parallel connection of up to four standard read\/write devices (SLG 4x, 7x series). This capability enables the module to manage multiple identification points simultaneously, making it a critical component for tracking and logistics applications in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMOBY I\u003c\/strong\u003e communication module (ASM424)\u003c\/li\u003e\n\u003cli\u003eDual serial interface: RS-232 \/ RS-422\u003c\/li\u003e\n\u003cli\u003eSupports 3964R transmission procedure\u003c\/li\u003e\n\u003cli\u003eParallel operation support for up to 4 standard SLG 4x \/ 7x read-write devices\u003c\/li\u003e\n\u003cli\u003eCompatible with PCs, SICOMP, and non-Siemens automation controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated logistics and material handling\u003c\/li\u003e\n\u003cli\u003eProduction line item tracking\u003c\/li\u003e\n\u003cli\u003eWarehouse management and identification systems\u003c\/li\u003e\n\u003cli\u003eIntegration of RFID identification points with third-party controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eMOBY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Protocol\u003c\/td\u003e\n\u003ctd\u003e3964R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Connected Devices\u003c\/td\u003e\n\u003ctd\u003e4 (SLG 4x \/ 7x)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is securely mounted in an appropriate control cabinet or enclosure to protect against environmental contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Configuration:\u003c\/strong\u003e Select the appropriate physical interface (RS-232 or RS-422) based on the host controller requirements and cable length limitations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded, twisted-pair cabling for serial communication to minimize electromagnetic interference (EMI) and ensure data integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressing:\u003c\/strong\u003e When connecting multiple SLG read\/write devices, ensure each device is properly addressed to support parallel operation within the ASM424 configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain a solid common ground connection between the communication module, the host controller, and the read\/write devices to prevent ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716776948075,"sku":"6GT2002-2CE00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gt2002-2ce00-nvqktc25axo_c64238e7-47cb-4e5f-b955-fdd6ad1e804b.jpg?v=1767089398","url":"https:\/\/www.plcprotech.com\/fa\/products\/siemens-6gt2002-2ce00-moby-i-asm424-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}