{"product_id":"siemens-sitrans-fm-mag-1100-f-flow-sensor-7me6140-2da22-2aa1","title":"سنسور جریان زیمنس SITRANS FM MAG 1100 F (7ME6140-2DA22-2AA1)","description":"\u003cp\u003eDescription\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSITRANS FM MAG 1100 F\u003c\/strong\u003e is a full-bore electromagnetic flow sensor specifically engineered for the food, beverage, and pharmaceutical industries. This \u003cstrong\u003e7ME6140-2DA22-2AA1\u003c\/strong\u003e model features a robust sanitary design suitable for measuring the volume flow of conductive liquids. It is built with a ceramic liner and Platinum electrodes, ensuring exceptional chemical resistance and durability in clean-in-place (CIP) and steam-in-place (SIP) processes. As a sensor designed for remote mounting, it provides high-precision measurement while allowing the transmitter to be located in a separate, more accessible area.\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSanitary Construction:\u003c\/strong\u003e Designed for high-hygiene applications in F\u0026amp;B and pharmaceutical sectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Integrity:\u003c\/strong\u003e Ceramic liner with FDA-compliant FPM\/FKM gaskets and Platinum electrodes for superior resistance to aggressive media.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-Bore Design:\u003c\/strong\u003e No moving parts, minimizing pressure loss and maintenance requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Compatibility:\u003c\/strong\u003e Optimized for use with remote SITRANS FM transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Versatility:\u003c\/strong\u003e Suitable for DN25 (1 inch) piping systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFood and beverage production (e.g., dairy, juice, beverage bottling)\u003c\/li\u003e\n\u003cli\u003ePharmaceutical manufacturing (e.g., batch processing, dosing)\u003c\/li\u003e\n\u003cli\u003eHigh-hygiene chemical processing\u003c\/li\u003e\n\u003cli\u003eConductive liquid flow measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical Specifications\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eSITRANS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e7ME6140-2DA22-2AA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003eDN25 (1 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiner Material\u003c\/td\u003e\n\u003ctd\u003eCeramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Material\u003c\/td\u003e\n\u003ctd\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal Material\u003c\/td\u003e\n\u003ctd\u003eFPM\/FKM (FDA compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.20kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e30.50 x 26.50 x 21.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLM Product Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eInstallation Guidelines\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the sensor is installed in a pipeline section where the pipe is always completely filled with the liquid to prevent measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Install the sensor in a vibration-free location, ideally with a straight pipe run of at least 3x the diameter upstream and 2x downstream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Proper grounding is critical for electromagnetic flowmeters; ensure grounding rings or electrodes are used if the piping material is non-conductive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHygiene Compliance:\u003c\/strong\u003e Since this model is \"not 3A approved,\" verify it meets the specific sanitary requirements and local regulations for your process environment before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Integration:\u003c\/strong\u003e Mount the remote transmitter within the cable length limitations specified for the sensor to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716780945771,"sku":"7ME6140-2DA22-2AA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/7me6140-2da22-2aa1-h5nfoshijvb_cedceef6-d011-4df4-8e08-e476233a9c2d.jpg?v=1767089538","url":"https:\/\/www.plcprotech.com\/fa\/products\/siemens-sitrans-fm-mag-1100-f-flow-sensor-7me6140-2da22-2aa1","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}