{"title":"Schneider Electric","description":"\u003cp\u003eSchneider Electric est un leader mondial de la transformation numérique, de la gestion de l'énergie et de l'automatisation industrielle. L'architecture de la marque intègre la plateforme EcoStruxure, unissant les systèmes \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/schneider-modicon-quantum\"\u003ePLC Modicon\u003c\/a\u003e, les \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/schneider-altivar-process\"\u003evariateurs Altivar\u003c\/a\u003e et les solutions de sécurité spécialisées \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/triconex\"\u003eTriconex\u003c\/a\u003e. Les principales caractéristiques techniques incluent des protocoles de communication ouverts, une haute efficacité énergétique et du matériel compatible IoT pour une fabrication intelligente. Fonctionnellement, les solutions Schneider offrent un contrôle complet, des machines discrètes aux infrastructures à grande échelle et aux centres de données. En combinant un matériel fiable avec des analyses basées sur les données, les composants Schneider Electric garantissent un temps de fonctionnement maximal, la durabilité et la sécurité dans les secteurs mondiaux de l'exploitation minière, de la chimie et de l'énergie.\u003c\/p\u003e","products":[{"product_id":"modicon-pc-e984-685-984-685-slot-mount-controller-cpu-ps","title":"Contrôleur CPU\/PS à montage sur slot MODICON PC-E984-685 (984-685)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon PC-E984-685 (984-685)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, slot-mount Programmable Logic Controller (PLC) that integrates a Central Processing Unit (CPU) and a Power Supply (PS) into a single module. Part of the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon 984\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries, the E984-685 is engineered for mid-to-large scale industrial automation tasks requiring robust logic processing and high-speed I\/O communication. This \"All-in-One\" architecture simplifies system planning by providing internal power for the CPU and the backplane while supporting the standard Modicon 800-Series I\/O. Its dual AC\/DC capability (115\/220 VAC input and 24 VDC output) makes it a versatile solution for heritage systems in manufacturing and process control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePC-E984-685\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is designed for deterministic execution and high-density memory management.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a built-in power supply that accepts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e115 VAC or 220 VAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(jumper\/switch selectable). It provides the necessary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand logic voltages required to power the CPU and up to a specific number of I\/O modules on the local rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with high-capacity user memory for logic (Relay Ladder Logic) and state RAM. It supports battery-backed CMOS RAM to ensure program retention during power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Communication Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically features two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus (RS-232\/RS-485)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eports, enabling simultaneous connection to a programming terminal (like a P190 or PC-based software) and a human-machine interface (HMI) or SCADA system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExecutive Firmware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller utilizes a swappable \"Executive\" cartridge or FLASH-based firmware that defines the instruction set and communication protocols, allowing for field updates to enhance functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePC-E984-685\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModicon (Schneider Electric)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 \/ 220 VAC (47 - 63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (For local I\/O and Logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8K to 16K (Model dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 1024 Discrete \/ 1024 Register\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e984-Series Slot Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBattery Backup\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium battery for CMOS RAM retention\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I clear a \"CPU Stopped\" error code on the E984-685?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA stopped CPU is often indicated by specific LED patterns (e.g., \"Ready\" LED off). Check the error codes using Modsoft or Concept software. Common causes include a depleted battery, memory parity errors, or an I\/O mismatch in the configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 24 VDC output to power external field devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePC-E984-685\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 24 VDC for internal rack logic and local 800-series modules, it is standard engineering practice to use a separate, dedicated external power supply for heavy field loads (solenoids, contactors) to prevent electrical noise from resetting the CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the \"Config Mode\" toggle switch?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe toggle switch allows the user to protect the memory (Run\/Protect) or place the CPU into a configuration state for Modbus port address assignment and baud rate setup.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Selection Jumper:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCRITICAL:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore applying power, verify the internal voltage selection jumper is set correctly for your local mains (115 VAC vs. 220 VAC). Applying 220 VAC to a unit set for 115 VAC will result in immediate hardware failure of the power supply stage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Noise Abatement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the PLC rack is grounded via a heavy-duty copper braid to a central \"Star\" ground point. Use shielded twisted-pair cables for Modbus communications to prevent electromagnetic interference (EMI) from high-power motor drives from corrupting the data stream.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReplace the lithium battery every 2-3 years while the unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epowered on\u003c\/strong\u003e. If the battery is removed while the unit is powered off, the user program and configuration will be lost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePC-E984-685\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis distinguished by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInstruction Set Stability\u003c\/strong\u003e. Unlike modern controllers that require frequent firmware patches, the 984-685 offers a \"frozen\" industrial logic environment that is highly predictable. Its integrated power supply reduces the physical footprint of the PLC system, making it an ideal choice for \"Retrofit-in-Place\" projects where enclosure space is limited but high-speed Modicon logic is still required.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695205937515,"sku":"MODICON PC-E984-685","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/modicon-pc-e984-685-model-685e-cpu-module-sj0s4kwb3qd_2b2d3c30-5f5c-4a2d-8ad5-07d46c4a0687.jpg?v=1766130685"},{"product_id":"schneider-electric-140cpu67060-modicon-quantum-unity-hot-standby-processor","title":"Processeur de veille chaude Schneider Electric 140CPU67060 Modicon Quantum Unity","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong\u003eUnity processor\u003c\/strong\u003e is designed for the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e to provide high-availability control through \u003cstrong\u003eHot Standby\u003c\/strong\u003e functionality. Operating at a clock frequency of \u003cstrong\u003e266 MHz\u003c\/strong\u003e, the module features an onboard memory of \u003cstrong\u003e512 KB\u003c\/strong\u003e dedicated for data RAM, with support for expandable program and file storage via PCMCIA cards.\u003c\/p\u003e\n\u003cp\u003eThe processor facilitates robust system distribution, managing up to \u003cstrong\u003e63 distributed I\/O stations\u003c\/strong\u003e and up to \u003cstrong\u003e6 Ethernet X80 remote I\/O racks (racks supporting up to 6 drops)\u003c\/strong\u003e. Local discrete and analogue I\/O configurations are explicitly restricted in Hot Standby setups to preserve system architecture integrity. Integrated communication capabilities feature multiple connection types including a dedicated \u003cstrong\u003emultimode fiber optic port\u003c\/strong\u003e utilizing the Hot Standby protocol, along with dedicated ports for \u003cstrong\u003eModbus\u003c\/strong\u003e, \u003cstrong\u003eModbus Plus\u003c\/strong\u003e, and \u003cstrong\u003eUSB\u003c\/strong\u003e connections. It is optimized for high-reliability \u003cstrong\u003eprocess control\u003c\/strong\u003e and automated verification checks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Availability Hot Standby\u003c\/strong\u003e: Features an integrated MT-RJ multimode fiber optic interface running a dedicated Hot Standby protocol to synchronize primary and secondary controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Memory Architecture\u003c\/strong\u003e: Provides 512 KB of internal data RAM, with expansion capabilities up to 8 MB for file storage and 7168 kB for application programs using PCMCIA cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Execution\u003c\/strong\u003e: Performs operations with an execution time of 0.0525...0.075 µs for Boolean instructions and 0.4...0.5 µs for floating-point calculations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Networking Range\u003c\/strong\u003e: Supports up to 3 local networks each for Modbus Plus, Ethernet TCP\/IP, and Profibus DP, alongside remote and distributed AS-Interface mapping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Rack Compatibility\u003c\/strong\u003e: Designed to operate within standard Modicon Quantum mounting structures, aligning with system setups from 2 to 16 slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Task Management\u003c\/strong\u003e: Formatted to execute 1 cyclic\/periodic master task, optimized specifically for deterministic process environment requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant power plant control systems\u003c\/li\u003e\n\u003cli\u003eContinuous chemical and petrochemical processing\u003c\/li\u003e\n\u003cli\u003eHigh-availability water and wastewater treatment facilities\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure and environmental monitoring\u003c\/li\u003e\n\u003cli\u003eLarge-scale industrial distributed I\/O installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClock Frequency\u003c\/td\u003e\n\u003ctd\u003e266 MHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Time (Boolean)\u003c\/td\u003e\n\u003ctd\u003e0.0525...0.075 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Time (Word)\u003c\/td\u003e\n\u003ctd\u003e0.045...0.06 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Time (Fixed-Point)\u003c\/td\u003e\n\u003ctd\u003e0.045...0.06 μs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Time (Floating-Point)\u003c\/td\u003e\n\u003ctd\u003e0.4...0.5 µs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNumber of Instructions per ms\u003c\/td\u003e\n\u003ctd\u003e20 Kinst\/ms (100% Boolean) \/ 15 Kinst\/ms (65% Boolean, 35% numerical) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSystem Overhead\u003c\/td\u003e\n\u003ctd\u003e1 ms master task \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal RAM Description\u003c\/td\u003e\n\u003ctd\u003e512 KB for data \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExpandable Program Memory\u003c\/td\u003e\n\u003ctd\u003eUp to 7168 kB with PCMCIA card \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExpandable File Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 8 MB with PCMCIA card \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSwitch Function\u003c\/td\u003e\n\u003ctd\u003eKey switch memory port on\/off \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity \u0026amp; Routing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e10, 16, 2, 4, 6 (rack-dependent) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNumber of Racks\u003c\/td\u003e\n\u003ctd\u003e2-local rack(s) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDistributed I\/O Stations\u003c\/td\u003e\n\u003ctd\u003e63 station(s) 1 rack(s) - 3 Modbus Plus network(s) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRemote I\/O Stations\u003c\/td\u003e\n\u003ctd\u003e6-2 ethernet X80 remote I\/O rack(s) (Up to 6 drops X80) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDiscrete \/ Analogue I\/O Limits\u003c\/td\u003e\n\u003ctd\u003e0-local (forbidden in Hot Standby application) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDistributed I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e8000 inputs, 8000 outputs \/ 500 inputs, 500 outputs per Modbus Plus network \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eApplication Specific I\/O\u003c\/td\u003e\n\u003ctd\u003eAccurate time stamping, Counter, High-speed interrupt inputs, Serial link \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e2500 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e1 LED red for Ethernet collision \/ 1 LED green for Ethernet activity (COM) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDimensions (Supported Racks)\u003c\/td\u003e\n\u003ctd\u003e290 mm Height; width varying from 104 mm to 671 mm based on 2 to 16 slot configurations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Connector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMT-RJ Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Multimode fiber optic port running Hot Standby protocol for primary\/secondary PLC interconnection up to 4 km \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Dedicated connection port for Modbus bus communication \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSUB-D 9 Female Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Dedicated connection port for Modbus Plus network interfacing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated connection type for local diagnostic and programming access \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Redundancy Interconnection\u003c\/strong\u003e: Connect the primary and secondary processors using standard MT-RJ multimode fiber optic cabling. The architecture supports a maximum physical length of up to 4 km between the paired controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Restrictions\u003c\/strong\u003e: Mount the processor securely into a compatible Modicon Quantum automation platform slot. Note that auxiliary tasks, timer interrupt tasks, standard interrupt tasks, I\/O interrupt tasks, and periodic fast tasks are explicitly forbidden when running a Hot Standby application configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Protection\u003c\/strong\u003e: Utilize the onboard functional hardware key switch to toggle the memory port on or off, protecting the configured data and program blocks from unauthorized local modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Segregation\u003c\/strong\u003e: Ensure proper termination on the Modbus Plus SUB-D 9 network line and monitor diagnostic LEDs to avoid communication collisions or packet losses across local paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: CE, CSA, GOST, UL, Misc (Marine) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: HazLoc \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSustainability \u0026amp; Directives\u003c\/strong\u003e: Green Premium product, RoHS compliant (since date code 1111 via Schneider Electric declaration of conformity), REACH reference not containing SVHC above the designated threshold \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the fiber optic port located on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MT-RJ multimode fiber optic interface is dedicated to running the integrated Hot Standby protocol, synchronizing primary and secondary processors over distances up to 4 km for seamless process control backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre local I\/O cards permitted in the same rack as the processor during redundant operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Local discrete and analogue I\/O configurations are forbidden when the processor is implemented within a Hot Standby system topology. All I\/O must be routed through distributed networks or Ethernet remote drops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is program memory expanded if the 512 KB data RAM is insufficient for full applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accommodates hardware memory expansion via PCMCIA cards, supporting up to 7168 kB for program storage and up to 8 MB for general file storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the integrated diagnostic LEDs on the faceplate indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe faceplate includes two distinct LED status indicators: a red LED that alerts the operator to an active Ethernet collision and a green LED that indicates ongoing Ethernet communication activity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695219798379,"sku":"140CPU67060","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-140cpu67060-cpu-single-slot-module-o0yn4ma0whp_5466774c-a84c-465c-b79c-6cff29a3bf2f.jpg?v=1766131065"},{"product_id":"ace949-2-schneider-electric-rs485-2-wire-interface-for-sepam-series","title":"Interface RS485 2 fils Schneider Electric ACE949-2 pour série Sepam","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric ACE949-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the critical communication bridge for the Sepam protective relay range, including the Series 20, 40, 60, and 80. As a high-performance RS485 2-wire interface, this module enables seamless integration of protection units into a Modbus RTU network (S-LAN or E-LAN). In complex power distribution environments, the ACE949-2 ensures real-time data transmission and remote monitoring of electrical parameters. Its compact, DIN-rail mounted design allows engineers to expand the communication capabilities of substation automation systems without sacrificing cabinet space. By facilitating robust 2-wire connectivity, the module provides a cost-effective and reliable solution for long-distance industrial telemetry.\u003c\/p\u003e\n\u003ch2\u003eKey Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eDual-Protocol Versatility\u003c\/h3\u003e\n\u003cp\u003eThe ACE949-2 architecture supports both S-LAN (System Local Area Network) and E-LAN (Engineering Local Area Network) configurations. This flexibility allows the module to function simultaneously as a reporting tool for SCADA systems and a dedicated port for remote engineering and parameter setting via software.\u003c\/p\u003e\n\u003ch3\u003eOptimized Power Management\u003c\/h3\u003e\n\u003cp\u003eDesigned for industrial efficiency, the module operates on a broad voltage range of 12 V DC to 24 V DC. It features intelligent power consumption management, drawing only 16 mA in receiving mode and peaking at 40 mA during active data transmission, ensuring minimal thermal load within the enclosure.\u003c\/p\u003e\n\u003ch3\u003eIndustrial-Grade Resilience\u003c\/h3\u003e\n\u003cp\u003eSchneider has engineered the ACE949-2 to withstand the rigors of harsh substation environments. The hardware meets stringent IEC 60255-21 standards for vibration, shock, and seismic activity (Level 2), ensuring the communication link remains intact even during mechanical disturbances or seismic events.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Signal Diagnostics\u003c\/h3\u003e\n\u003cp\u003eA front-facing LED indicator provides instantaneous visual feedback on link activity. This hardware-level diagnostic tool allows maintenance personnel to verify communication status at a glance, significantly reducing troubleshooting time during commissioning or network faults.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Name\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACE949-2 (Ref: 59642)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSepam Series 20, 40, 48, 60, 80, 80 NPP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485 - 2-wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU (E-LAN or S-LAN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 V DC \/ 24 V DC (+\/- 10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSymmetrical DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25°C to 70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e88 mm (H) x 72 mm (W) x 30 mm (D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeismic Robustness\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Gn (Horizontal), 1 Gn (Vertical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003ch3\u003eCommunication Distance and Voltage Calibration\u003c\/h3\u003e\n\u003cp\u003eCable performance varies based on the supply voltage and the number of connected devices. For maximum reliability, adhere to the following distance constraints:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e24 V DC Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 1000m for 5 devices, or 375m for 25 devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12 V DC Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 320m for 5 devices, or 125m for 25 devices.\u003c\/p\u003e\n\u003cp\u003eAlways use shielded twisted pair cables to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEarthing and Shielding\u003c\/h3\u003e\n\u003cp\u003eThe ACE949-2 requires a dedicated earthing connection to maintain signal integrity. Use the screw-type terminal for a tinned copper braid (6…100 mm²) or a standard cable (2.5…50 mm²). Ensure the earth lead length remains under 0.2 meters and is tightened to a torque of 2.2 N.m.\u003c\/p\u003e\n\u003ch3\u003eMounting Logic\u003c\/h3\u003e\n\u003cp\u003eInstall the module on a symmetrical DIN rail within the same cubicle as the Sepam relay. Maintain adequate clearance around the unit to allow for heat dissipation, even though the unit has low power consumption.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe ACE949-2 is the industry standard for securing the longevity of Sepam-based protection schemes. Its primary advantage lies in its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eElectromagnetic Compatibility (EMC)\u003c\/strong\u003e; it is tested against 2.5 kV damped oscillating waves and 4 kV fast transients, making it virtually immune to the electrical noise common in high-voltage switchgear environments. While Schneider has announced a future discontinuation (Dec 2026), the ACE949-2 remains the essential \"drop-in\" spare for existing infrastructure, ensuring that legacy systems remain fully communicative and compliant with safety protocols through 2030 and beyond.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: \u003c\/strong\u003eThe datasheet mentions the ACE949-2 will be discontinued soon. Should I still buy it?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1: \u003c\/strong\u003eYes. Schneider Electric has committed to \"End-of-Service\" support until December 31, 2030. For existing Sepam Series installations, the ACE949-2 is the exact OEM replacement required to maintain system integrity without needing to re-engineer the entire communication architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Can I use the ACE949-2 for a 4-wire RS485 network?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2: \u003c\/strong\u003eNo. The ACE949-2 is specifically designed for 2-wire RS485 networks. If your system requires a 4-wire configuration, you must select the appropriate 4-wire interface module (such as the ACE950) to ensure protocol compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e How does the supply voltage affect my network length?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Supply voltage is directly proportional to the allowable cable distance. Utilizing a 24 V DC power source nearly triples the effective range compared to a 12 V DC source (e.g., 750m vs 180m for 10 devices), which is critical for large-scale industrial plants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: \u003c\/strong\u003eWhat is the significance of the LED on the front face?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4: \u003c\/strong\u003eThe LED provides real-time link activity monitoring. A flashing LED confirms that the Modbus RTU polling is successful, allowing for rapid identification of whether a communication failure is due to hardware\/wiring or software configuration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695403626859,"sku":"ACE949-2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-ace949-2-interface-module-rloiqethywk_8637d61d-5e9f-48eb-b40d-3872696a404a.jpg?v=1766133922"},{"product_id":"schneider-atv61hd22n4z-variable-speed-drive","title":"Variateur de vitesse Schneider ATV61HD22N4Z","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric ATV61HD22N4Z\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance variable frequency drive (VFD) from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAltivar 61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. This series was specifically engineered for variable torque applications, making it a legacy standard for controlling pumps and fans in building management and industrial processes.\u003c\/p\u003e\n\u003cp\u003eThe \"Z\" suffix typically denotes a version supplied without the DC choke, often used in specific cabinet-build configurations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAltivar 61 (ATV61)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 kW \/ 30 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 to 480 V AC (3-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 A (at 4 kHz \/ 400 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Transient Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e52.8 A (for 60 seconds)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 to 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Open Style)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eControl \u0026amp; Communication\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Laws:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScalar (\u003cspan class=\"math-inline\"\u003e$V\/f$\u003c\/span\u003e), Flux Vector Control (Sensorless), and specialized Energy Saving ratios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus and CANopen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports communication cards (Profibus, DeviceNet, Ethernet) and I\/O extension cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Application Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes a specific law to reduce motor losses by up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30%\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunder low-load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePump\/Fan Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures integrated \"Catch on the Fly\" (restarting a spinning fan), sleep\/wake modes, and multi-pump control (with card).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafe Torque Off (PWR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal to prevent accidental motor starts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustomization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMacros for specialized functions like \"Pumping,\" \"Ventilation,\" or \"General Use\" simplify the initial setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Maintenance Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for vertical mounting in an electrical enclosure. Because it is an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit, it must be protected from dust and moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit generates approximately\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e685 W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof heat at full load. Ensure the cabinet fan capacity is sufficient to keep the ambient temperature below\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$50^\\circ C$\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Choke:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNote that the \"Z\" version may require an external line reactor or DC choke to comply with harmonic distortion limits, depending on your local grid requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded motor cables to minimize electromagnetic interference (EMI). Keep control wiring and power wiring in separate conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this drive for a conveyor or crane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile possible, it is not recommended. The ATV61 is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVariable Torque\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(pumps\/fans). For constant torque applications like conveyors or hoists, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAltivar 71 (ATV71)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor the newer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATV930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries is more appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the replacement model for the ATV61?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Altivar 61 series is now largely superseded by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAltivar Process ATV630\u003c\/strong\u003e. The ATV630 offers superior energy monitoring and embedded Ethernet as standard.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I clear a \"PLF\" (Phase Loss) fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the input power supply for a dropped phase. If the input is fine, inspect the DC bus connections. If you are running the motor on a test bench without a load, you may need to disable the \"Output Phase Loss\" check in the fault management menu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support PID control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ATV61 has a built-in PID regulator for pressure or flow control, allowing it to adjust motor speed based on a feedback signal from a 4-20mA or 0-10V sensor.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695403725163,"sku":"ATV61HD22N4Z","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-atv61hd22n4z-variable-speed-drive-ttezyqhr2on_0cb7a1e8-801a-4e60-84af-ea9464b643ec.jpg?v=1766133928"},{"product_id":"schneider-atv630d45n4-variable-speed-drive","title":"Variateur de vitesse Schneider ATV630D45N4","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric ATV630D45N4\u003c\/strong\u003e is a high-performance variable speed drive (VSD) from the \u003cstrong\u003eAltivar Process ATV600\u003c\/strong\u003e range. Designed specifically for industrial processes and utilities, it excels in fluid management (pumps, fans, and compressors) by offering embedded energy management and asset monitoring functions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAltivar Process ATV600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMotor Power (Normal Duty)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 kW \/ 60 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMotor Power (Heavy Duty)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e37 kW \/ 50 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 to 480 V AC (3-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLine Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e81.5 A (at 380 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63.9 kVA (at 480 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e88 A (at 4 kHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunication \u0026amp; Control\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEtherNet\/IP, Modbus TCP, Modbus Serial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExpansion Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSlot A (I\/O expansion), Slot B (Communication modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\/Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 DI (STU\/Safe Torque Off), 3 Relay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs\/Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 AI (software configurable), 2 AO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP21 (UL Type 1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmbedded Intelligence:\u003c\/strong\u003e Features \"Stop-and-Go\" functions to reduce energy consumption during standby and an integrated \"Pump Curve\" tool to optimize hydraulic performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAsset Management:\u003c\/strong\u003e Includes an embedded web server and dynamic QR codes for instant access to diagnostics and maintenance data via a smartphone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integration:\u003c\/strong\u003e Comes standard with \u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e SIL3\/PLe, reducing the need for external safety contactors while meeting global safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonic Mitigation:\u003c\/strong\u003e Built-in DC choke limits total harmonic distortion (\u003cspan class=\"math-inline\"\u003e$THDi$\u003c\/span\u003e) to less than 48% without additional filters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling Requirements:\u003c\/strong\u003e The unit dissipates approximately \u003cstrong\u003e990 W\u003c\/strong\u003e of heat at full load. Ensure adequate ventilation in the enclosure and maintain the minimum clearance distances (top\/bottom\/sides) specified in the mounting manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded motor cables to comply with EMC requirements. Ensure the ground connection (PE) is secure and follows a star-point grounding scheme to minimize electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e The ATV630D45N4 is designed for wall mounting or enclosure mounting. It must be installed vertically (\u003cspan class=\"math-inline\"\u003e$10^\\circ$\u003c\/span\u003e tolerance) to ensure proper heat convection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Protection:\u003c\/strong\u003e Use high-speed fuses or a circuit breaker (e.g., Schneider TeSys GV4) rated for the drive's input current to protect against short circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between \"Normal Duty\" and \"Heavy Duty\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNormal Duty (45 kW) is for applications with low overload requirements (up to 110% for 60s), like centrifugal pumps. Heavy Duty (37 kW) is for high-torque applications (up to 150% for 60s), like conveyors or positive displacement pumps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I control this drive via a PLC over Ethernet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The dual Ethernet\/IP and Modbus TCP ports allow for seamless integration with Schneider Modicon PLCs or other industrial controllers like Rockwell or Siemens.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Stop-and-Go\" function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis function automatically puts the drive into a low-power state when the motor is not required to run, reducing internal consumption by up to \u003cstrong\u003e60%\u003c\/strong\u003e during idle periods.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Graphic Display Terminal included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, standard ATV630 models include a removable plain text graphic display terminal that supports multi-language diagnostics and parameter backup.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52695403954539,"sku":"ATV630D45N4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/schneider-atv630d45n4-variable-speed-drive-jqwynpsxcww_5e55a8d2-e0a6-4789-873c-b098f556cc51.jpg?v=1766133943"},{"product_id":"schneider-bmxftb2000-modicon-m340-terminal-block","title":"Bloc de bornes Schneider BMXFTB2000 Modicon M340","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBMXFTB2000\u003c\/strong\u003e is a 20-pin removable connection block engineered specifically for the \u003cstrong\u003eModicon M340\u003c\/strong\u003e automation platform. This specialized terminal component serves as the central physical interface to bridge discrete or analog field wiring directly to the system's input and output processing modules. By mapping the active sensor and actuator signal lines into a high-density configuration, it enables uninterrupted electrical continuity for complex process manufacturing and machinery control loops.\u003c\/p\u003e\n\u003cp\u003eDesigned for perfect integration within the \u003cstrong\u003eModicon M340\u003c\/strong\u003e hardware ecosystem, this removable cage clamp block simplifies panel wiring and speeds up maintenance routines. It features a standalone plug-in design that permits quick-swapping or card replacement without the need to individually detach, label, or re-terminate field conductors. The robust internal cage clamp contacts exert continuous, uniform tension on bare or ferruled copper wires, ensuring reliable gas-tight connections that withstand structural machine vibration inside industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDeveloped as a dedicated system accessory for the \u003cstrong\u003eModicon M340\u003c\/strong\u003e \/ X80 automation series to guarantee exact structural alignment.\u003c\/li\u003e\n\u003cli\u003eEquipped with a 20 removable cage clamp terminal block layout to streamline heavy-duty field terminations.\u003c\/li\u003e\n\u003cli\u003eNatively accommodates single-conductor wiring profiles with cross-sectional areas from 0.34 mm2 to 1 mm2.\u003c\/li\u003e\n\u003cli\u003eFormulated as a removable connection block to support efficient module servicing and minimize layout repair intervals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eField wire termination for \u003cstrong\u003eModicon M340\u003c\/strong\u003e digital inputs, digital outputs, and low-level analog I\/O hardware module lines.\u003c\/li\u003e\n\u003cli\u003eMarshalling and signal distribution within plant control cabinets, local operator stations, and motor control centers (MCC).\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure monitoring networks including municipal wastewater facilities, material conveyor grids, and chemical treatment plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eAll mechanical dimensions, packaging quantities, and material ratings are compiled directly from the official factory engineering documentation:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.823%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 31.9637%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 50.2587%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eCompatibility Range\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eModicon M340 \/ Modicon X80 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eAccessory Type\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eRemovable connection block \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNumber of Terminals\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e20 removable cage clamp terminal block \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eAccessory Destination\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eFor module with 20-pin removable terminal block \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eValid Conductor Size\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e1 x 0.34..1 mm2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNet Product Weight\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e0.093 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eUnit Type of Package 1\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003ePCE \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNumber of Units in Package 1\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 1 Height\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e3.500 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 1 Width\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e4.500 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 1 Length\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e11.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 1 Weight\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e109.000 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eUnit Type of Package 2\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eS02 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNumber of Units in Package 2\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e60 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 2 Height\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e15.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 2 Width\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e30.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 2 Length\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e40.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 2 Weight\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e6.941 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eUnit Type of Package 3\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003eP06 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eNumber of Units in Package 3\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e960 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 3 Height\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e75.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 3 Width\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e80.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 3 Length\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e60.000 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003ePackage 3 Weight\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e119.056 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 16.823%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 31.9637%;\"\u003eContractual Warranty\u003c\/td\u003e\n\u003ctd style=\"width: 50.2587%;\"\u003e18 months \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Connection:\u003c\/strong\u003e Orient the plug-in block alignment grooves to match the front tracking lip of the \u003cstrong\u003eModicon M340\u003c\/strong\u003e module, then slide inward until the locking tabs snap firmly into the primary module housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Termination:\u003c\/strong\u003e Strip the outer protective jacket of the single-conductor copper cable to the exact depth specified by the installation print before sliding it into the open cage clamp terminal pocket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp Mechanism:\u003c\/strong\u003e Compress the cage clamp internal spring by introducing a flat-head terminal tool, position the bare copper wire into the terminal seat, and withdraw the tool to implement a uniform, continuous-pressure hold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBundle Protection:\u003c\/strong\u003e Bind the incoming field wires using the retention anchors built into the terminal outer frame to eliminate downstream pull forces or twisting stress on individual termination pins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Status:\u003c\/strong\u003e Active pro-active compliance with EU RoHS Directive parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Composition:\u003c\/strong\u003e Completely toxic heavy metal free and mercury free.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegional Directives:\u003c\/strong\u003e Certified under the official China RoHS Declaration framework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Notices:\u003c\/strong\u003e California Proposition 65 warning provided regarding potential trace exposure limits for Lead and lead compounds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this 20-pin terminal block fit onto 40-pin Modicon M340 high-density modules?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eNo, this component is configured specifically for \u003cstrong\u003eModicon M340\u003c\/strong\u003e modules built with a corresponding 20-pin front interface layout. High-density 40-pin modules require a larger and entirely separate connection block assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this part number include the electronic I\/O module card or only the terminal block?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThis part number represents the standalone 20-pin removable cage clamp terminal block accessory. The central processing units and primary I\/O electronic cards must be acquired separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sizes of field wiring can be reliably clamped into this connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated cage clamps are certified to securely terminate single-conductor copper wire sizes ranging from a minimum of 0.34 mm2 to a maximum of 1 mm2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to pull this terminal assembly away from the M340 module while the rack is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the system allows for the removal and insertion of accessories under power in safe, ordinary locations, all external field-side current loops and voltages must be analyzed first to eliminate hazardous electrical tracking or shocks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104508567915,"sku":"BMXFTB2000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bmxftb2000-w4iwyobv4nz.png?v=1776162982"},{"product_id":"schneider-electric-atv320u55n4b-altivar-machine-atv320-variable-speed-drive","title":"Variateur de vitesse variable Altivar Machine ATV320 Schneider Electric ATV320U55N4B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong\u003evariable speed drive\u003c\/strong\u003e is engineered for \u003cstrong\u003ecomplex machines\u003c\/strong\u003e requiring reliable motor control and specialized safety features. Operating within a rated supply voltage range of \u003cstrong\u003e380...500 V\u003c\/strong\u003e alternating current (AC) across \u003cstrong\u003e3 phases\u003c\/strong\u003e, it delivers a nominal output current of \u003cstrong\u003e14.3 A\u003c\/strong\u003e and supporting a motor power of \u003cstrong\u003e5.5 kW\u003c\/strong\u003e designated for \u003cstrong\u003eheavy duty\u003c\/strong\u003e operations.\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates extensive input and output options, featuring \u003cstrong\u003e7 discrete inputs\u003c\/strong\u003e, \u003cstrong\u003e3 discrete outputs\u003c\/strong\u003e, \u003cstrong\u003e3 analogue inputs\u003c\/strong\u003e, and \u003cstrong\u003e1 analogue output\u003c\/strong\u003e. It integrates a \u003cstrong\u003eClass C2 EMC filter\u003c\/strong\u003e and offers embedded communication over \u003cstrong\u003eModbus serial\u003c\/strong\u003e and \u003cstrong\u003eCANopen\u003c\/strong\u003e. For enhanced application compatibility, optional communication modules such as \u003cstrong\u003eEtherCAT\u003c\/strong\u003e, \u003cstrong\u003eProfibus DP V1\u003c\/strong\u003e, \u003cstrong\u003ePROFINET\u003c\/strong\u003e, \u003cstrong\u003eEthernet Powerlink\u003c\/strong\u003e, \u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e, and \u003cstrong\u003eDeviceNet\u003c\/strong\u003e can be utilized. Built-in functional safety capabilities include \u003cstrong\u003eSafe torque off (STO)\u003c\/strong\u003e, \u003cstrong\u003eSafe Stop 1 (SS1)\u003c\/strong\u003e, and \u003cstrong\u003eSafely Limited Speed (SLS)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Control Profiles\u003c\/strong\u003e: Supports multiple asynchronous motor control profiles (Voltage\/Frequency ratios in 2 or 5 points, quadratic U\/f for Energy Saving, and flux vector control without sensor) along with synchronous vector control without sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Safety Capabilities\u003c\/strong\u003e: Embedded with functional safety capabilities, explicitly featuring \u003cstrong\u003eSafe torque off (STO)\u003c\/strong\u003e, \u003cstrong\u003eSafe Stop 1 (SS1)\u003c\/strong\u003e, and \u003cstrong\u003eSafely Limited Speed (SLS)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Torque Performance\u003c\/strong\u003e: Delivers a transient overtorque capacity of \u003cstrong\u003e170...200%\u003c\/strong\u003e of the nominal motor torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Protective Braking\u003c\/strong\u003e: Equipped with an integrated \u003cstrong\u003ebrake chopper\u003c\/strong\u003e and supports braking to standstill via \u003cstrong\u003eDC injection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-Quadrant Operation\u003c\/strong\u003e: Supports full \u003cstrong\u003e4 quadrant operation\u003c\/strong\u003e for driving and braking in both forward and reverse directions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptable Ramp Profiles\u003c\/strong\u003e: Provides customizable acceleration and deceleration ramps including linear, U, S, CUS, ramp switching, automatic stop with DC injection, and ramp adaptation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Slip Compensation\u003c\/strong\u003e: Provides load-independent automatic motor slip compensation, which is adjustable from \u003cstrong\u003e0...300%\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackaging machinery\u003c\/li\u003e\n\u003cli\u003eMaterial handling and conveying systems\u003c\/li\u003e\n\u003cli\u003eTextile manufacturing equipment\u003c\/li\u003e\n\u003cli\u003eHoisting and lifting mechanisms\u003c\/li\u003e\n\u003cli\u003eWoodworking and metal processing machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9009%; height: 3469.72px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 58.8068px;\"\u003e\n\u003cth style=\"width: 24.1035%; height: 58.8068px;\"\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 29.7262%; height: 58.8068px;\"\u003e\u003cstrong\u003eTechnical Specification Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 42.0052%; height: 58.8068px;\"\u003e\u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eFormat of the Drive\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eBook \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e\u003cstrong\u003eElectrical Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eRated Supply Voltage [Us]\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e380...500 V (-15% to +10%) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e50...60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.8068px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 58.8068px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 58.8068px;\"\u003eRelative Symmetric Network Frequency Tolerance\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 58.8068px;\"\u003e5% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eLine Current\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e20.7 A at 380 V \/ 14.5 A at 500 V (heavy duty) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e20.7 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eProspective Line Isc\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e22 kA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e\u003cstrong\u003eElectrical Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eMotor Power kW\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e5.5 kW for heavy duty \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e14.3 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eBase Load Current at High Overload\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e14.3 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e500 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eMaximum Output Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e0.599 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eApparent Power\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e12.6 kVA at 500 V (heavy duty) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e2...16 kHz adjustable \/ 4...16 kHz with derating factor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eNominal Switching Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e4 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eDiscrete Input Number\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e7 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 295.597px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 295.597px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 295.597px;\"\u003eDiscrete Input Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 295.597px;\"\u003e\n\u003cp\u003eSTO safe torque off: 24 V DC, 1.5 kOhm\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eDI1...DI6 logic inputs: 24 V DC (max 30 V)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eDI5 programmable as pulse input: 0...30 kHz, 24 V DC (max 30 V) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eDiscrete Input Logic\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003ePositive logic (source) \/ Negative logic (sink) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 165.597px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 165.597px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 165.597px;\"\u003eDiscrete Output Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 165.597px;\"\u003e\n\u003cp\u003eOpen collector DQ+: 0...1 kHz, 30 V DC, 100 mA\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eOpen collector DQ-: 0...1 kHz, 30 V DC, 100 mA \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eAnalogue Input Number\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 295.597px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 295.597px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 295.597px;\"\u003eAnalogue Input Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 295.597px;\"\u003e\n\u003cp\u003eAI1 voltage: 0...10 V DC, 30 kOhm, 10 bits\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eAI2 bipolar differential voltage: +\/- 10 V DC, 30 kOhm, 10 bits\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eAI3 current: 0...20 mA (configurable to 4-20 mA, x-20 mA, 20-x mA), 250 Ohm, 10 bits \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eAnalogue Output Number\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 185.199px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 185.199px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 185.199px;\"\u003eAnalogue Output Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 185.199px;\"\u003e\n\u003cp\u003eSoftware-configurable current AQ1: 0...20 mA, 800 Ohm, 10 bits\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eSoftware-configurable voltage AQ1: 0...10 V DC, 470 Ohm, 10 bits \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 457.585px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 457.585px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 457.585px;\"\u003eRelay Output Type\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 457.585px;\"\u003e\n\u003cp\u003eConfigurable relay logic R1A: 1 NO (100,000 cycles)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eConfigurable relay logic R1B: 1 NC (100,000 cycles)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eConfigurable relay logic R1C\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eConfigurable relay logic R2A: 1 NO (100,000 cycles)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eConfigurable relay logic R2C \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 445.199px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 445.199px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 445.199px;\"\u003eRelay Switching Limits\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 445.199px;\"\u003e\n\u003cp\u003eResistive load (cos phi = 1): 3 A at 250 V AC or 30 V DC (R1A, R1B, R1C)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eInductive load (cos phi = 0.4, L\/R = 7 ms): 2 A at 250 V AC or 30 V DC (all relays)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eResistive load (cos phi = 1): 5 A at 250 V AC or 30 V DC (R2A, R2C)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eMinimum: 5 mA at 24 V DC (all relays) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e\u003cstrong\u003ePerformance \u0026amp; Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eRegulation Loop\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eAdjustable PID regulator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eSpeed Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e+\/- 10% of nominal slip from 0.2 Tn to Tn \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eFan: 195.0 W at 380 V, switching frequency 4 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eMounting Mode\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eWall mount \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e150 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e308.0 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e232.0 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eProduct Weight\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e4.4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eOperating Position\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eVertical +\/- 10 degrees \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eIP20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eEnvironmental Class\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eClass 3C3 and Class 3S2 according to IEC 60721-3-3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eClass 3K5 according to EN 60721-3 \u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eShock Resistance\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003eMax acceleration: 150 m\/s^2 at 11 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 165.597px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 165.597px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 165.597px;\"\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 165.597px;\"\u003e\n\u003cp\u003eMax acceleration: 10 m\/s^2 at 13...200 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eMax deflection: 1.5 mm at 2...13 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eCooling Air Volume\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e60 m3\/h \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003eIII \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 19.6023px;\"\u003ePollution Degree\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 19.6023px;\"\u003e2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 145.994px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 145.994px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 145.994px;\"\u003eAmbient Air Temp (Operation)\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 145.994px;\"\u003e\n\u003cp\u003e-10...50 degC without derating\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e50...60 degC with derating factor \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eAmbient Air Temp (Storage)\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e-25...70 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 24.1035%; height: 39.2045px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 29.7262%; height: 39.2045px;\"\u003eAmbient Air Temp (Transport)\u003c\/td\u003e\n\u003ctd style=\"width: 42.0052%; height: 39.2045px;\"\u003e-25...70 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSTO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafe Torque Off functional safety input (24 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDI1...DI4, DI6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital logic inputs (24 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDI5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital logic input \/ Programmable pulse input (0...30 kHz, 24 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDQ+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen collector discrete output (0...1 kHz, 30 V DC, 100 mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDQ-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen collector discrete output (0...1 kHz, 30 V DC, 100 mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAI1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue voltage input (0...10 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAI2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBipolar differential analogue voltage input (+\/- 10 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAI3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue current input (0...20 mA \/ 4-20 mA configurable) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAQ1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware-configurable analogue output (0...20 mA or 0...10 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Normally Open (NO) contact \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR1B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Normally Closed (NC) contact \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR1C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Common terminal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Normally Open (NO) contact \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR2C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs - Common terminal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus serial \/ CANopen integrated communication interface \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation\u003c\/strong\u003e: Mount the drive vertically. Deflections must remain within +\/- 10 degrees from the true vertical position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation and Cooling\u003c\/strong\u003e: Ensure unimpeded airflow around the chassis. The internal cooling fan requires a minimum air volume flow of \u003cstrong\u003e60 m3\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating\u003c\/strong\u003e: For operational environments between -10 degC and 50 degC, no derating is necessary. If the ambient operating temperature rises between 50 degC and 60 degC, an appropriate technical derating factor must be applied.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enclosure\u003c\/strong\u003e: The unit carries an \u003cstrong\u003eIP20\u003c\/strong\u003e rating and must be mounted inside an industrial enclosure providing protection against airborne contaminants, conforming to pollution degree 2 limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectives \u0026amp; Standards\u003c\/strong\u003e: EN\/IEC 61800-5-1 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Marks \u0026amp; Approvals\u003c\/strong\u003e: CE, ATEX, UL, CSA, GOST, EAC, RCM, KC, NOM \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental \u0026amp; Sustainability\u003c\/strong\u003e: Green Premium Product, REACH Declaration, EU RoHS Directive, China RoHS Declaration, Mercury Free \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility\u003c\/strong\u003e: Immunity levels evaluated to IEC 61000-4-2 (Level 3), IEC 61000-4-3 (Level 3), IEC 61000-4-4 (Level 4), IEC 61000-4-5 (Level 3), IEC 61000-4-6 (Level 3), and IEC 61000-4-11 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat embedded communication interfaces are immediately accessible on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe variable speed drive comes standard with an integrated slave CANopen and Modbus serial interface protocol via its primary communication port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be adapted to other industrial fieldbus networks like PROFINET or EtherCAT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Communication modules for external networking architectures including PROFINET, EtherCAT, Profibus DP V1, Ethernet Powerlink, EtherNet\/IP, and DeviceNet are fully compatible via option card slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the default pulse configuration for the discrete logic input terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features 7 discrete inputs where terminal DI5 can be explicitly programmed to handle pulse configurations up to 30 kHz at 24 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this system require an external braking chopper for heavy-duty overhauling loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. An internal brake chopper is integrated directly within the unit, allowing for energy absorption and DC injection braking to standstill.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat thermal conditions must be maintained during active operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe operating range spans -10 degC up to 50 degC without losing performance metrics. Operation up to 60 degC is permissible provided a specific derating factor is implemente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104521052523,"sku":"ATV320U55N4B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv320u55n4b-4ehlwxfqier.png?v=1776162461"},{"product_id":"schneider-electric-140amm09000-modicon-quantum-analog-input-output-module","title":"Module d'entrée\/sortie analogique Modicon Quantum Schneider Electric 140AMM09000","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong\u003einput\/output analog module\u003c\/strong\u003e is designed for the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e to provide high-precision analog signal interfacing within industrial control systems. The hardware integrates a single-pole low-pass filter providing a attenuation of -3 dB at 21 Hz (+\/- 20%) on the input circuit to manage electrical noise and ensure signal integrity.\u003c\/p\u003e\n\u003cp\u003eConfigured with \u003cstrong\u003e6 channels\u003c\/strong\u003e in total, the unit provides \u003cstrong\u003e4 analog inputs\u003c\/strong\u003e and \u003cstrong\u003e2 analog outputs\u003c\/strong\u003e. It features an addressing requirement of \u003cstrong\u003e5 input words\u003c\/strong\u003e and \u003cstrong\u003e2 output words\u003c\/strong\u003e. The input channels accommodate both bipolar and unipolar ranges, including \u003cstrong\u003ebipolar current (+\/- 20 mA)\u003c\/strong\u003e, \u003cstrong\u003ebipolar voltage (+\/- 10 V, +\/- 5 V)\u003c\/strong\u003e, \u003cstrong\u003eunipolar current (0...20 mA)\u003c\/strong\u003e, and configured offsets such as \u003cstrong\u003e4...20 mA\u003c\/strong\u003e and \u003cstrong\u003e1...5 V\u003c\/strong\u003e. The output circuits operate within a \u003cstrong\u003e4...20 mA\u003c\/strong\u003e range with an external loop voltage requirement. This combination allows reliable data acquisition and control tracking in continuous process fields.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Modularity\u003c\/strong\u003e: Features a 6-channel architecture providing 4 independent inputs and 2 dedicated outputs within a standard module format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Input Capabilities\u003c\/strong\u003e: Supports multiple signal configurations including unipolar current, unipolar offset current, bipolar current, unipolar voltage, and bipolar voltage profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Noise Suppression\u003c\/strong\u003e: Incorporates an integrated single-pole low-pass filter rated at -3 dB at 21 Hz (+\/- 20%) on the input circuit paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Conversion\u003c\/strong\u003e: Delivers up to 16-bit resolution for voltage inputs, 15-bit for standard current inputs, and 12-bit resolution for the analog output loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Bus Isolation\u003c\/strong\u003e: Provides electrical isolation rated at 500 V AC or 750 V DC for 1 minute between independent channels, channels and bus, and between input\/output blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostic LEDs\u003c\/strong\u003e: Equipped with direct local signaling including a green bus active status indicator, a red external fault indicator, and 6 green\/red status markers for per-channel status and faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater and wastewater treatment monitoring\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n\u003cli\u003eBoiler control and steam management systems\u003c\/li\u003e\n\u003cli\u003eContinuous speed and position tracking loops\u003c\/li\u003e\n\u003cli\u003eMulti-channel data acquisition systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue Input Number\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Modularity\u003c\/td\u003e\n\u003ctd\u003e6 channels \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Input Types \u0026amp; Resolution\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBipolar current: +\/- 20 mA (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eBipolar voltage: +\/- 10 V (16 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eBipolar voltage: +\/- 5 V (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar current: 0...20 mA (15 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar offset current: 4...20 mA (14 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar offset voltage: 1...5 V (14 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar voltage: 0...10 V (16 bits DC)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eUnipolar voltage: 0...5 V (15 bits DC) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAbsolute Maximum Input\u003c\/td\u003e\n\u003ctd\u003e+\/- 25 mA current \/ +\/- 50 V voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm voltage \/ \u0026gt; 250 Ohm current \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB 50\/60 Hz input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUpdate Time (Input)\u003c\/td\u003e\n\u003ctd\u003e320 ms input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Number\u003c\/td\u003e\n\u003ctd\u003e2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Range\u003c\/td\u003e\n\u003ctd\u003e4...20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAnalogue Output Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExternal Power Requirement\u003c\/td\u003e\n\u003ctd\u003e7...30 V DC output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLoop Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e0...60 V DC with external resistance output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e30 V DC 20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSetting Time\u003c\/td\u003e\n\u003ctd\u003e900 µs to +\/- 0.1% of the final value output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUpdate Time (Output)\u003c\/td\u003e\n\u003ctd\u003e15 ms output circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Demands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e5 input words \/ 2 output words \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e350 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy \u0026amp; Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute Accuracy Error\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.03% at 25 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.20% of full scale at 25 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.05% of full scale max at 25 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.004% of full scale at 0...60 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOffset Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-0.0014 % of full scale max\/degC 0...60 degC input circuit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eGain Shift\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/- 0.002 of full scale max 0...60 degC input circuit\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e+\/-0.007 %\/degC of full scale max at 0...60 degC output circuit \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute \/ 750 V DC for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eChannel to Bus Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute \/ 750 V DC for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput to Output Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V for 1 minute \/ 750 V for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% without condensation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmbient Air Temp (Operation)\u003c\/td\u003e\n\u003ctd\u003e0...60 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmbient Air Temp (Storage)\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIndicator \/ Terminal Status\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Active LED (Green)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates active backplane bus communication is present \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Fault LED (Red)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates an external fault condition has been detected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Active LEDs (6x Green)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually indicates that the corresponding channel is turned on \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Fault LEDs (6x Red)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually indicates an active fault on the corresponding channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Placement\u003c\/strong\u003e: Mount the standard format module within a verified Modicon Quantum rack slot. Ensure proper retention screws are fastened to resist mechanical stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Connection\u003c\/strong\u003e: Secure an external power supply ranging from 7...30 V DC to drive the analog output circuit loops effectively.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Use twisted-pair shielded cables for analog signal line routing. Ground the shields according to standard engineering practices to optimize common mode rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Thresholds\u003c\/strong\u003e: Ensure ambient air temperatures remain between 0 and 60 degC during active system operation, with relative humidity held below 95% without condensation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA C22.2 No 142, UL 508 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: CE, C-Tick.1, FM Class 1 Division 2 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Field Resistance\u003c\/strong\u003e: 10 V\/m 80...2000 MHz conforming to IEC 801-3 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSustainability \u0026amp; Directives\u003c\/strong\u003e: Green Premium product, RoHS compliant (since date code 0842 Schneider Electric declaration of conformity), REACH reference not containing SVHC above the designated threshold \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific fault types can the diagnostic circuit paths register?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module detects an open circuit condition on both the input and output lines, an overtracking scale error on unipolar input loops, and updates the dedicated status byte for output parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the built-in filtering circuit on this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach input incorporates a single-pole low-pass filter providing an attenuation of -3 dB at 21 Hz (+\/- 20%) to damp high-frequency electrical noise before signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the analog output section draw its operating voltage directly from the backplane bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the module requires 350 mA from the backplane bus for internal processing, the analog output loop requires an independent external power connection supplying 7...30 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the isolation parameters between the input and output sides of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal dielectric boundaries provide continuous isolation rated up to 500 V AC or 750 V DC for 1 minute between the input channels and output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104522494315,"sku":"140AMM09000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140amm09000-ahxygsogmnz.png?v=1776159463"},{"product_id":"schneider-electric-nsycu2k-climasys-cu-enclosure-active-cooling-unit","title":"Unité de refroidissement active ClimaSys NSYCU2K Schneider Electric","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\n\u003cp\u003e\nThe Schneider Electric \u003cstrong\u003eNSYCU2K\u003c\/strong\u003e is a heavy-duty, side-mounting electronic enclosure climate controller belonging to the specialized ClimaSys CU product family. Engineered to maintain rigorous thermal stabilization inside sealed electrical cabinets, this compressor-based system delivers a nominal cooling power of 2000 W under standard L35-L35 rating criteria. In volatile process environments such as oil and gas refining, thermal power generation facilities, and automated aggregate processing plants, excessive thermal pockets lead directly to the premature tripping or permanent failure of high-density PLCs, variable frequency drives, and system backplanes. The \u003cstrong\u003eNSYCU2K\u003c\/strong\u003e mitigates these structural risks by forcefully extracting internal heat loads while maintaining a continuous environmental barrier. The dual-loop circuit layout isolates contaminated factory air from the clean interior loop, driving down heat-induced processing downtime and protecting high-value control assets.\n\u003c\/p\u003e\n\n\u003ch3\u003eHardware Infrastructure \u0026amp; Fluid Dynamics\u003c\/h3\u003e\n\n\u003cp\u003e\nThe mechanical architecture of this active cooling system is built upon a rigid, industrial-grade steel chassis finished in standard RAL 7035 grey coating. Designed specifically for indoor screw-mount integration on enclosure doors or side panels, it uses a closed-loop R134a refrigerant system charged with 0.54 kg of gas to achieve an Energy Efficiency Ratio (EER) of 1.9. The unit incorporates high-capacity motorized fans that move air through the internal circuit at 860 m3\/h and the external ambient loop at 1050 m3\/h. For automated configuration, an onboard digital electronic controller regulates system operation based on selectable parameters, adapting automatically to distinct thermal thresholds across 50 Hz and 60 Hz electrical networks.\n\u003c\/p\u003e\n\n\u003ch3\u003eCore Technical Parameters Matrix\u003c\/h3\u003e\n\n\u003ctable\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003eCertified Performance Data\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eModel\u003c\/td\u003e\n            \u003ctd\u003eNSYCU2K\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eBrand\u003c\/td\u003e\n            \u003ctd\u003eSchneider Electric\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eRange\u003c\/td\u003e\n            \u003ctd\u003eClimaSys CU\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMounting Type\u003c\/td\u003e\n            \u003ctd\u003eSide-mount or Door-mount (Indoor)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eRated Power Consumption\u003c\/td\u003e\n            \u003ctd\u003e1080 W at L35-L35 \/ 1290 W at L35-L50\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNominal Cooling Power\u003c\/td\u003e\n            \u003ctd\u003e2000 W at L35-L35 \/ 1510 W at L35-L50\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInput Operating Voltage\u003c\/td\u003e\n            \u003ctd\u003e230 VAC, 1-phase, 50\/60 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eFull Load Rated Current\u003c\/td\u003e\n            \u003ctd\u003e6.5 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePeak Inrush Current\u003c\/td\u003e\n            \u003ctd\u003e24 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eIntegrated Gas Charge\u003c\/td\u003e\n            \u003ctd\u003eR134a (0.54 kg)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTarget Temperature Set Window\u003c\/td\u003e\n            \u003ctd\u003e20 to 55 deg C (50 Hz) \/ 20 to 50 deg C (60 Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInternal Loop Protection\u003c\/td\u003e\n            \u003ctd\u003eIP55 conforming to IEC 60529\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eExternal Loop Protection\u003c\/td\u003e\n            \u003ctd\u003eIP34 conforming to IEC 60529\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSound Pressure Level\u003c\/td\u003e\n            \u003ctd\u003e65 dB conforming to EN\/ISO 3746\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMaximum System Pressure\u003c\/td\u003e\n            \u003ctd\u003e25 bar\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNet Weight\u003c\/td\u003e\n            \u003ctd\u003e52 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n            \u003ctd\u003e999 mm Height x 405 mm Width x 237 mm Depth\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eField Diagnostics \u0026amp; Application FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eWhy does the system list two distinct cooling capacities (2000 W and 1510 W)?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nCooling output depends on thermal gradients. Under L35-L35 parameters (internal cabinet air and external ambient air both at 35 deg C), the unit outputs its full 2000 W capacity. When ambient plant temperatures rise to 50 deg C (L35-L50 conditions), the compressor works against a higher thermal head, reducing net sensible cooling output to 1510 W while power consumption climbs to 1290 W.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eWhat specific protective electrical hardware must be installed upstream of this unit?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nDue to the inductive startup profile of the compressor motor, which draws a transient 24 A inrush current, a dedicated thermal protection fuse rated at 10 A (Time-delay \/ Type T) or a magnetic motor circuit breaker with matching delay characteristics must be installed to prevent nuisance tripping during start-up cycles.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCan this unit operate reliably in high-dust or chemical fiber environments?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nYes, but it requires accessory hardware. While the internal circuit is sealed to IP55, the unsealed external circuit operates at IP34. For areas with high concentrations of airborne particulate matter, non-conductive dust, or fibers, field technicians must install the optional external circuit filter to keep the condenser fins clear and maintain proper heat transfer efficiency.\n\u003c\/p\u003e\n\n\u003ch3\u003eField Commissioning \u0026amp; Structural Installation Guide\u003c\/h3\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eMechanical Panel Preparation:\u003c\/strong\u003e Utilize the factory cutout blueprint to trace and execute precise intake and exhaust apertures on the side panel or door of the Spacial enclosure. Remove all metal shavings, smooth out raw cut lines, and treat the bare steel borders with zinc-rich anti-corrosion primer before proceeding with mechanical fastening.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eGasket Compression and Sealing:\u003c\/strong\u003e Apply the continuous polyurethane sealing strip around the rear chassis mounting perimeter without overlaps or gaps. Lift the 52 kg unit using mechanical hoist assists and secure it via the specified mounting screws through the cabinet wall. Tighten fasteners uniformly to ensure uniform gasket compression, establishing the certified IP55 internal loop barrier.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eAirstream Path Clearances:\u003c\/strong\u003e To maintain optimal air movement profiles (860 m3\/h internal \/ 1050 m3\/h external), ensure internal panel components, wireways, or structural plates sit at least 150 mm away from the internal intake and exhaust vents. Externally, maintain a minimum clear radius of 500 mm to prevent the re-ingestion of hot exhaust air.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n            \u003cstrong\u003eCondensate Management and Slope:\u003c\/strong\u003e Mount the cooling unit perfectly plumb in both horizontal and vertical planes onto a rigid structure. Misalignments or tilting can disrupt the internal gravity-fed condensation path, leading to localized water accumulation or moisture migration into the low-voltage areas of the industrial enclosure.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104571810155,"sku":"NSYCU2K","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nsycu2k-pcxq3jda0fs.png?v=1776163430"},{"product_id":"tsxpbsca100-schneider-electric-modicon-quantum-profibus-dp-cable-100m","title":"Câble Profibus DP Modicon Quantum TSXPBSCA100 Schneider Electric 100m","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100 (TSXPBSCA100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premium-grade Profibus DP communication cable engineered for high-speed data transmission within the Schneider Electric Modicon Quantum and Premium automation platforms. This 100 m (328 ft) bulk cable reel is specifically designed to facilitate robust connectivity between Profibus master\/slave modules and field devices in distributed I\/O architectures. Utilized extensively in large-scale industrial sectors such as water wastewater treatment, automotive assembly, and chemical processing, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures low-latency communication over long distances. Its industrial-strength shielding is critical for maintaining signal integrity in environments saturated with electromagnetic interference (EMI), effectively preventing data packet loss and minimizing network-related system downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized RS-485 based twin-axial cable optimized for the Profibus DP (Decentralized Periphery) protocol. The internal architecture features high-purity copper conductors protected by a high-density braided shield and foil wrap, providing dual-layer protection against high-frequency noise and electrical transients. The outer jacket is composed of a durable, flame-retardant compound capable of withstanding the rigors of industrial cable trays and conduits. This cable is designed for use with standard 9-pin D-Sub Profibus connectors, supporting transmission speeds up to 12 Mbps. Its 100 m length provides the flexibility needed for expansive plant layouts, allowing for the strategic positioning of remote I\/O drops without the need for frequent repeaters.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eTSXPBSCA100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eModicon Quantum \/ Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eProfibus DP Communication Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003e100 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eTransmission Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eUp to 12 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eCommunication Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eProfibus DP (RS-485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003e5.34 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003e33 x 33 x 13.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003e85444290\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 41.8773%;\"\u003e\u003cspan\u003eProduct Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.7617%;\"\u003e\u003cspan\u003eActive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the TSXPBSCA100 cable be used for both Profibus DP and Profibus PA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is specifically optimized for Profibus DP (RS-485).\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-975\"\u003eWhile the physical layer of Profibus PA is different (Manchester Bus Powered), the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan class=\"citation-975 citation-end-975\"\u003e\u003cspan\u003e \u003c\/span\u003eis the standard for high-speed DP communication between PLCs and devices like variable speed drives or remote I\/O.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it necessary to use specific connectors with this 100 m reel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, for industrial reliability, it is recommended to use Schneider Electric 490NAE91102 or equivalent Profibus connectors. These connectors provide the necessary termination resistors required at the physical ends of the network segment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum segment length supported by this cable at 1.5 Mbps?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccording to Profibus standards, a single segment using this type of high-quality cable can reach up to 200 m at 1.5 Mbps. For the full 12 Mbps speed, the segment length should generally not exceed 100 m without a repeater.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, strictly observe a minimum bend radius of at least 75 mm. Kinking or over-bending the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan deform the internal dielectric and shielding geometry, leading to impedance mismatches and signal reflections that cause intermittent bus errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Continuity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen stripping the cable for connector assembly, ensure the braided shield makes 360-degree contact with the metal housing of the Profibus connector. This ensures a continuous path to ground for induced noise, which is vital for the 12 Mbps high-speed data rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparation from Power Cabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo avoid inductive coupling, maintain a minimum clearance of 20 cm between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand AC power cables (above 230V). If the communication cable must cross a power cable, ensure it does so at a 90-degree angle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Check:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways verify that the termination switches on the connectors at the first and last physical nodes of the 100 m segment are set to the \"ON\" position. Intermediate nodes must have the termination switch set to \"OFF\" to prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572760427,"sku":"TSXPBSCA100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxpbsca100-ahsijylm3kk.png?v=1776164423"},{"product_id":"schneider-electric-tsxpbsca400-modicon-quantum-profibus-dp-connection-cable","title":"Câble de connexion Profibus DP Modicon Quantum TSXPBSCA400 Schneider Electric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPBSCA400 (TSX-PBS-CA400)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Profibus DP connection cable engineered for the Modicon Quantum automation platform. Spanning a total length of 400 meters, this specialized communication medium is designed to facilitate seamless data exchange between PLC processors and remote I\/O stations in demanding industrial environments such as oil refineries, power generation plants, and large-scale mining operations. Given its Phase-Out status, securing this original Schneider Electric component is critical for maintaining legacy infrastructure integrity, preventing costly downtime, and ensuring the deterministic performance required for mission-critical control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eAs a dedicated Profibus DP (Decentralized Periphery) physical layer component, this cable features optimized impedance and shielding characteristics to mitigate electromagnetic interference (EMI) over long-distance runs. The 400-meter bulk reel allows for custom length termination or extensive trunk line deployment without the need for additional repeaters in many standard RS-485 network topologies. It is fully compliant with the Modicon Quantum architecture, supporting high-speed cyclic data exchange and diagnostics across the Profibus fieldbus network.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXPBSCA400\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Quantum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfibus DP Connection Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 x 50 x 41.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85444290\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfibus DP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TSXPBSCA400 compatible with other Modicon series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile specifically categorized under the Modicon Quantum range, this cable follows standard Profibus DP physical layer specifications and can be utilized with Modicon M580 or M340 systems provided the appropriate Profibus communication modules and connectors are employed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Phase-Out status affect future maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs this product is in the Phase-Out phase, Schneider Electric may limit new production. It is highly recommended to maintain onsite spares to ensure immediate recovery during cable damage scenarios, as lead times for legacy accessories typically increase over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the grounding requirements for a 400-meter run?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent ground loops while maintaining EMI protection, the cable shield should be integrated via 360-degree contact at the connector level. In extended runs, ensure that the potential equalization between different plant areas is within the specified limits of the Profibus standard.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, maintain a minimum bend radius of at least 15 times the outer diameter of the cable. Excessive kinking can alter the internal geometry of the twisted pair, leading to signal reflection and intermittent \"Bus Heavy\" errors in the PLC diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparation from Power Lines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity, route this cable in separate conduits from high-voltage motor leads or VFD outputs. A minimum clearance of 20 cm is recommended in parallel runs to prevent inductive coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough designed for industrial use, if the cable is routed through areas with high chemical exposure or standing water, it must be protected by liquid-tight flexible conduits. Ensure all Profibus connectors are tightened to the specified torque to maintain IP-rated seals at the module interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572957035,"sku":"TSXPBSCA400","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxpbsca400-053kxpxmjyq.png?v=1776164424"},{"product_id":"schneider-modicon-quantum-140dai74000-discrete-input-module","title":"Module d'entrée discrète Modicon Quantum Schneider 140DAI74000","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e140DAI74000\u003c\/strong\u003e is a 16-channel discrete input module engineered for the \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e. Operating at a nominal voltage of 230 V AC, this module provides the interfacing capacity necessary to register high-voltage digital signals from field devices such as pushbuttons, limit switches, and electrical interlocks. It captures alternating current states and processes them into a single 1 input word format for execution within the main processor rack.\u003c\/p\u003e\n\u003cp\u003eIntegrated into the system architecture via \u003cstrong\u003eUnity Pro\u003c\/strong\u003e, \u003cstrong\u003eConcept\u003c\/strong\u003e, or \u003cstrong\u003eProWORX 32\u003c\/strong\u003e programming frameworks, the module interfaces with the local controller backplane via standard bus routing protocol. The unit is specialized for high-power processing environments where separate tracking of independent AC input circuits is mandatory to prevent cross-talk and maintain signal safety. It handles discrete data conversion with an optimized response time profile and high electrical isolation thresholds between channels as well as across the bus lines.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures 16 discrete input channels structured in an isolated group layout \u003c\/li\u003e\n\u003cli\u003eOperates on a wide 230 V AC input range compatible with dual network frequencies (57...63 Hz or 47...53 Hz) \u003c\/li\u003e\n\u003cli\u003eHigh channel-to-channel and channel-to-bus galvanic isolation rated at 1780 Vrms for 1 minute \u003c\/li\u003e\n\u003cli\u003eEquipped with front-panel local signaling LEDs including 1 green bus communication indicator, 1 red external fault warning, and 16 green individual input status lights \u003c\/li\u003e\n\u003cli\u003eLow bus current requirement of 180 mA to optimize backplane power distribution \u003c\/li\u003e\n\u003cli\u003eStandard module format fits seamlessly into any open Modicon Quantum slot position \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain power plant control and distribution substation monitoring\u003c\/li\u003e\n\u003cli\u003eHeavy infrastructure control systems including municipal water treatment facilities\u003c\/li\u003e\n\u003cli\u003eSafety interlocking logic for high-voltage industrial machinery and switchgears\u003c\/li\u003e\n\u003cli\u003eMarine and offshore production platform auxiliary process systems\u003c\/li\u003e\n\u003cli\u003eManufacturing lines utilizing 230 V AC field machinery sensor arrays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eVAC discrete input modules \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Number\u003c\/td\u003e\n\u003ctd\u003e16 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup of Channels\u003c\/td\u003e\n\u003ctd\u003e16 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e1 input word \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt;= 11.5 mA at 57...63 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e\u0026lt;= 9.7 mA at 47...53 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage State 1 Guaranteed\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e165...264 V AC at 57...63 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e175...264 V AC at 47...53 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage State 0 Guaranteed\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0...40 V AC at 57...63 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e0...40 V AC at 47...53 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e26500 Ohm capacitive at 57...63 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e31800 Ohm capacitive at 47...53 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency Limits\u003c\/td\u003e\n\u003ctd\u003e47...63 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.6 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Input\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e264 V continuous\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e300 V 10 s\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e400 V 1 cycle \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.9...0.75 ms x line cycle Off-On\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e7.3...12.3 ms On-Off \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Between Channels\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Between Channels and Bus\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e180 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5.5 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature for Operation\u003c\/td\u003e\n\u003ctd\u003e0...60 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Air Temperature for Storage\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% without condensation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance to Electrostatic Discharge\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 kV contact conforming to IEC 801-2\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e8 kV on air conforming to IEC 801-2 \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance to Electromagnetic Fields\u003c\/td\u003e\n\u003ctd\u003e10 V\/m 80...2000 MHz conforming to IEC 801-3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Turn off all rack power supplies prior to positioning the input module into the target Quantum slot. Push the unit firmly until the module connector fully seats into the backplane bus interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Routing:\u003c\/strong\u003e Route all high-voltage 230 V AC external field cabling through separate wire ducts distinct from low-voltage DC signals and communication lines to mitigate cross-coupling and electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Requirements:\u003c\/strong\u003e Verify that the enclosure layout preserves natural convection airways. Ensure the operating environment does not surpass the upper thermal barrier of 60 degC and that non-condensing moisture stays within 95% relative humidity constraints.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Earth Grounding:\u003c\/strong\u003e Confirm the main Modicon Quantum mounting rack features an uncompromised, low-impedance ground bonding strap connected directly to the primary structural earth terminal of the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMarking: CE \u003c\/li\u003e\n\u003cli\u003eStandards: CSA C22.2 No 142, UL 508 \u003c\/li\u003e\n\u003cli\u003eProduct Certifications: FM Class 1 Division 2, CUL \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the distinct front-panel signaling LEDs mean during normal operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe top green LED remains illuminated when active bus communication is running across the backplane. The red LED illuminates if an external fault is detected. The remaining block of 16 green LEDs individually follow the on\/off state transitions of the corresponding AC field input lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum allowed temporary voltage spike that the inputs can withstand?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe input channels tolerate absolute maximum voltage boundaries up to 300 V for a duration of 10 seconds and 400 V for a brief single line cycle without suffering permanent component failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be programmed using standard EcoStruxure Control Expert software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, since this module functions under the standard Unity Pro engine framework, it remains compatible with legacy Unity Pro applications as well as updated development suites from Schneider Electric.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573186411,"sku":"140DAI74000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140dai74000-d5awyvvdwhg.png?v=1776159574"},{"product_id":"schneider-modicon-premium-tsxispy121-isp-plus-weighing-module","title":"Module de pesage Schneider Modicon Premium TSXISPY121 ISP Plus","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXISPY121\u003c\/strong\u003e functions as a high-precision \u003cstrong\u003eISP Plus weighing module\u003c\/strong\u003e developed for integration within the \u003cstrong\u003eModicon Premium Automation platform\u003c\/strong\u003e. This specialized hardware subassembly executes rapid industrial weight data acquisition, supporting processing rates of up to 50 measurements per second. The device features a single measurement input channel with an analogue input resolution of 20 bits, translating to an internal capacity of 1,048,857 points. Designed to supply stabilized power directly to connected sensors, it outputs a constant 10 V DC sensor power supply to drive external field components.\u003c\/p\u003e\n\u003cp\u003eFor localized process adjustments, the hardware incorporates \u003cstrong\u003ediscrete reflex\u003c\/strong\u003e outputs with a rapid response time of 1 ms, handling positive switching states up to 500 mA at 24 V DC. Communication infrastructure is facilitated by an unisolated RS485 serial link operating at a transmission rate of 9.6 kbit\/s, enabling dedicated connection paths directly to a Magelis weight indicator. This architecture makes the module highly suitable for industrial batching, filling, and dynamic crane or hopper weighing procedures across modern production lines.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Conversion\u003c\/strong\u003e: Employs a 20-bit internal analog-to-digital converter achieving a total resolution of 1,048,857 points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Measuring Frequency\u003c\/strong\u003e: Executes up to 50 discrete weight measurements per second for responsive automation tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Reflex Outputs\u003c\/strong\u003e: Provides 2 positive reflex outputs with an ultra-low response time of 1 ms for precise batch cutoff control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Sensor Power Management\u003c\/strong\u003e: Supplies an onboard 10 V DC power path dedicated exclusively to attached bridge load cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Serial Bus\u003c\/strong\u003e: Features a built-in unisolated RS485 serial link optimized for dedicated remote weight indicators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Premium Form Factor\u003c\/strong\u003e: Built to fit seamlessly into standard Modicon Premium rack slot allocations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial container and silo hopper weight monitoring\u003c\/li\u003e\n\u003cli\u003eHigh-speed automated batching and formula blending systems\u003c\/li\u003e\n\u003cli\u003eMaterial packaging, bagging, and inline check-weighing machinery\u003c\/li\u003e\n\u003cli\u003eCrane overload protection and heavy material handling tracking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric (LC Schneider) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTSXISPY121 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon Premium Automation platform \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISP Plus weighing module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Measurement Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue Input Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 bits (1048576 points) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 measurements per second \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MOhm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad cell 1...8 350 Ohm yes \u0026lt;= 300 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete reflex 2 positive \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time on Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s RS485 non isolated \u0026lt;= 30 m discrete reflex weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Division\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 uV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Cable Distance Between Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 m for module\/weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 mA at 24 V rack \/ 150 mA at 5 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.02 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 Celsius \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...70 Celsius \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...95% non-condensing (operation) \/ 5...95% non-condensing (storage) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...2000 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Interface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 connector screw terminal block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUsed for connecting 2 discrete reflex outputs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 female connector SUB-D 15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated for the indicator input lines \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 female connector SUB-D 9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides the RS485 serial link connection to the weight indicator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eRack Placement and Insertion\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the primary rack power supply of the Modicon Premium automation platform is switched off before inserting or extracting the hardware.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly along the structural chassis alignment paths until the rear terminal contacts mate completely into the active rack bus lines.\u003c\/li\u003e\n\u003cli\u003eTighten the integrated faceplate screws to confirm grounding and safeguard against vibration displacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Length and Isolation Management\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKeep the interconnection distance between the main weighing block and the dedicated remote weight indicator below the specified 3 m distance boundary to avoid transmission losses.\u003c\/li\u003e\n\u003cli\u003eWhen implementing field extensions for the load cell inputs, ensure the maximum shielding run does not exceed 300 m.\u003c\/li\u003e\n\u003cli\u003eRun all low-voltage analog load cell sensor cabling inside isolated trays, separated completely from primary high-current AC machinery power lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE \u003c\/li\u003e\n\u003cli\u003eSDM No 97.06 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat parameters govern the sensor compatibility for this weighing module?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe module is designed to interface seamlessly with standard strain-gauge load cells, supporting configurations ranging from 1 to 8 parallel load cells with a nominal bridge resistance of 350 Ohm up to a maximum distance boundary of 300 m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary electrical draws exerted by this unit on the main rack assembly?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe device pulls electrical current across two distinct voltage rails provided by the Modicon backplane, consuming 145 mA at the 24 V rack supply line while simultaneously drawing 150 mA from the localized 5 V DC internal distribution rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the direct physical reflex output channels bound to external switching loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e External loops hook directly into the integrated terminal interface using a dedicated single connector screw terminal block layout, which distributes the two positive 24 V DC reflex switching points out to localized relays or indicators.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573219179,"sku":"TSXISPY121","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxispy121-muccmmkuu2c.png?v=1776164103"},{"product_id":"schneider-modicon-premium-tsxp572623-pl7-processor-module","title":"Module processeur PL7 Modicon Premium Schneider TSXP572623","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXP572623\u003c\/strong\u003e is a single-slot processor module designed for the \u003cstrong\u003eModicon Premium\u003c\/strong\u003e automation platform. It manages autonomous PLC stations, coordinates distributed I\/O, and executes specialized tasks such as counting, motion control, and communication processing via the \u003cstrong\u003ePL7 Software\u003c\/strong\u003e environment.\u003c\/p\u003e\n\u003cp\u003eThis processing unit coordinates real-time discrete and analog operations across industrial machinery, manufacturing lines, and process control infrastructure. It features embedded system memory for application code, registers, and system diagnostics, with hardware support for localized rack configurations and distributed fieldbus networking. The module maintains full backward and vertical architectural consistency with the standard \u003cstrong\u003eTSX 57\u003c\/strong\u003e product range.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard single-slot form factor for Modicon Premium TSXRKY rack mounting\u003c\/li\u003e\n\u003cli\u003eIntegrated system flash memory for firmware and application logic protection\u003c\/li\u003e\n\u003cli\u003eDual PCMCIA card slots for memory extension and auxiliary network communication\u003c\/li\u003e\n\u003cli\u003eEmbedded diagnostic indicators for system status, I\/O faults, and communication states\u003c\/li\u003e\n\u003cli\u003eBuilt-in real-time clock for system timestamping and structured event logging\u003c\/li\u003e\n\u003cli\u003eSoftware configuration and application programming using PL7 Micro, Junior, or Pro\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive assembly lines and component testing machinery\u003c\/li\u003e\n\u003cli\u003eWater and wastewater pumping stations and treatment facilities\u003c\/li\u003e\n\u003cli\u003eMaterial handling, sorting systems, and conveyor line management\u003c\/li\u003e\n\u003cli\u003ePackaging infrastructure and high-speed filling equipment\u003c\/li\u003e\n\u003cli\u003eAuxiliary process loop controls in food, beverage, and chemical plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTSXP572623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slot Width\u003c\/td\u003e\n\u003ctd\u003e1 Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e1650 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissipated Power\u003c\/td\u003e\n\u003ctd\u003e8.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e96 Kwords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Software Support\u003c\/td\u003e\n\u003ctd\u003ePL7 Micro \/ Junior \/ Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e40 mm x 150 mm x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.380 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTER Port\u003c\/td\u003e\n\u003ctd\u003eRS485 Serial port for programming terminal or local HMI connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAUX Port\u003c\/td\u003e\n\u003ctd\u003eAuxiliary serial communication port for peripheral devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard Slot A\u003c\/td\u003e\n\u003ctd\u003ePCMCIA memory extension slot (SRAM or Flash memory cards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard Slot B\u003c\/td\u003e\n\u003ctd\u003ePCMCIA network\/fieldbus interface slot (Fipway, Modbus Plus, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Ensure the rack power supply is completely switched off before inserting or extracting the processor module from the backplane. Secure the module using the top and bottom chassis locking screws to guarantee reliable grounding to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling and Clearance:\u003c\/strong\u003e Maintain clear ventilation paths above and below the rack assembly. Allow at least 100 mm of clearance space from wire ducts or cabinet walls to promote natural convection cooling. Do not operate the unit in ambient environments exceeding 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e The processor grounds automatically through the backplane contacts. Verify that the TSXRKY rack frame is connected to the central functional earth bar of the enclosure using a low-impedance copper strap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Maintenance:\u003c\/strong\u003e Replace the auxiliary memory backup battery while the PLC system remains powered up to prevent accidental data loss from volatile internal registers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is required to configure and program this processor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe processor is fully programmed, configured, and diagnosed using PL7 software versions supporting TSX 57 architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be hot-swapped while the rack is live?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module must be powered down. Always isolate the main rack power supply before inserting or removing the processor to prevent permanent hardware damage or unexpected system states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat purpose do the built-in PCMCIA slots serve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlot A accepts memory expansion cards to increase available program or data memory, while Slot B supports physical communication cards for connection to upstream architectures or industrial networks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573284715,"sku":"TSXP572623","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp572623-3na11yzfv0p.png?v=1776164292"},{"product_id":"schneider-electric-140cpu65150c-modicon-quantum-unity-processor","title":"Processeur Unity Modicon Quantum 140CPU65150C Schneider Electric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-923\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e140CPU65150C (140-CPU-65150C)\u003c\/strong\u003e\u003cspan class=\"citation-923 citation-end-923\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Unity processor designed for the Modicon Quantum automation platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-922 citation-end-922\"\u003eFeaturing a 166 MHz clock speed and 768 KB of internal memory, this controller is engineered to handle complex logic, advanced floating-point calculations, and high-speed data processing in demanding industrial environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe \"C\" suffix denotes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion, providing enhanced protection against corrosive atmospheres (conformal coating), making it the gold standard for wastewater treatment, chemical processing, and harsh manufacturing plants. As a Phase-Out component, this processor remains vital for maintaining the operational continuity of legacy Unity Pro-based systems without requiring a full-scale migration to the M580 series.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-921 citation-end-921\"\u003eThis processor utilizes the Unity Pro (now EcoStruxure Control Expert) programming environment, supporting five IEC languages for maximum flexibility.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware architecture includes integrated communication ports and a high-speed internal bus interface. It is capable of managing extensive I\/O configurations and supports sophisticated redundancy schemes. The conformal coating applied to the internal PCBA ensures long-term reliability in environments where salt spray, moisture, or chemical vapors would typically cause premature failure in standard non-coated electronic assemblies.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140CPU65150C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Quantum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eClock Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e166 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory (User)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e768 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coated (Harsh Environment)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.50 x 32.50 x 11.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgramming Software\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnity Pro \/ EcoStruxure Control Expert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"C\" in the 140CPU65150C model number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" indicates that the module is conformally coated.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-920 citation-end-920\"\u003eThis involves applying a thin polymeric film to the circuit board, which protects against moisture, dust, chemicals, and temperature extremes.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is essential for installations in \"harsh\" or \"corrosive\" environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a non-coated 140CPU65150 with this 140CPU65150C version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 140CPU65150C is a direct functional replacement for the standard 140CPU65150. It offers identical performance and programming compatibility but provides superior environmental resilience.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this processor support Ethernet communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 140CPU65150C features integrated ports for local diagnostics and basic communication, but for high-capacity Ethernet\/IP or Modbus TCP networking across the plant, it is typically paired with a 140NOE series Ethernet module.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal memory is volatile and relies on a battery for data retention during power-off states. Always monitor the \"BAT\" LED indicator on the front panel. It is recommended to replace the battery every 12 to 24 months, even if the indicator is not yet active, to prevent losing the application program during a site power failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot Swapping Caution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the Modicon Quantum backplane supports \"Hot Swap\" for many I\/O modules, the CPU should never be removed or inserted while the backplane power supply is active. Doing so can cause electrical arcing or memory corruption. Always power down the rack before servicing the processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen deploying this CPU in a Hot Standby (Redundant) configuration, ensure that both the primary and standby 140CPU65150C units are running the exact same firmware version (OS). Incompatibilities in firmware versions will prevent the system from entering a healthy redundant state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573383019,"sku":"140CPU65150C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140cpu65150c-o2n5nnh5sjf.png?v=1776159527"},{"product_id":"schneider-tsxsay1000c-coated-as-interface-master-module","title":"Module maître AS-Interface revêtu TSXSAY1000C Schneider","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized AS-Interface (AS-i) Master Module designed for the Schneider Electric Modicon Premium automation platform. This \"C\" version is characterized by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coating (Humiseal 1A33)\u003c\/strong\u003e, which provides superior protection against moisture, dust, and chemical contaminants, making it ideal for harsh industrial environments. Operating as a bridge between the Modicon Premium rack and the AS-i cabling system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV2 standard and extended addressing\u003c\/strong\u003e, allowing for a highly flexible and scalable network of actuators and sensors. By simplifying field wiring into a single two-wire cable for both power and data, this module significantly reduces installation costs and improves diagnostic capabilities in complex automated systems such as bottling plants, conveyor networks, and specialized machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TSXSAY1000C is engineered for high-density networking and robust environmental performance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAS-i V2 Capabilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports the M2E profile, enabling the management of standard slaves as well as extended addressing slaves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlave Capacity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 31 slaves (Analog I\/O, Discrete 4I\/4O, or Safety interfaces).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 62 slaves (Discrete 4I\/3O), significantly increasing the network's point density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTreated with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHumiseal 1A33\u003c\/strong\u003e, ensuring long-term reliability in corrosive atmospheres or high-humidity zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHost Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowered directly via the Modicon Premium backplane (450 mA at 5 V DC), eliminating the need for external module power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Diversity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of interfacing with a variety of modules including safety-rated interfaces and analog I\/O units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Physical Layer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a 3-way male SUB-D connector for secure and reliable connection to the AS-i bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXSAY1000C (Coated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAS-i Version\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eV2 (Standard and Extended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlave Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e[AS-i] M2E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtective Treatment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating (Humiseal 1A33)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0…60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.34 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Modules (TSX574+)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 per base controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many modules can I install in a TSX57310 processor rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the TSX573 series, the system supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAS-i master modules per base controller. This allows for massive decentralized I\/O scaling within a single PLC project.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"C\" designation in TSXSAY1000C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated\u003c\/strong\u003e. While the standard TSXSAY1000 is suitable for clean industrial environments, the TSXSAY1000C is designed for \"Harsh\" environments where airborne pollutants or humidity could otherwise cause short circuits or corrosion on the PCB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module provide power to the AS-i bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the module takes its own logic power (450 mA) from the Premium rack, the AS-i bus itself requires a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAS-i Power Supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(usually 30 V DC with integrated data decoupling) to power the field sensors and actuators.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAddressing and Commissioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen using extended addressing (V2), ensure that your slaves are also V2 compliant. Extended addressing divides the standard 31 addresses into \"A\" and \"B\" banks, allowing for 62 total devices. Use the local signaling display unit on the front of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXSAY1000C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto identify address conflicts or bus faults during the initial power-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and SUB-D Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3-way SUB-D connector is the primary gateway to the AS-i bus. Use high-quality, shielded AS-i yellow flat cable for the field run. Ensure that the total cable length does not exceed 100 meters without the use of AS-i repeaters. Even with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHumiseal 1A33 coating\u003c\/strong\u003e, ensure the SUB-D connector is firmly tightened to maintain a gas-tight seal at the connection point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP20 rating means the module must be installed in an enclosure. Because this is the coated version, it is specifically intended for cabinets located in \"Class 3C2\" or similar environments. Maintain a vertical mounting orientation to facilitate natural convection, as the module consumes nearly 2.25 Watts of power from the backplane, which must be dissipated to stay within the 0…60 °C operating range.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573809003,"sku":"TSXSAY1000C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxsay1000c-qe1acipseoe.png?v=1776164526"},{"product_id":"140xsm00200-schneider-electric-modicon-quantum-16-switch-input-simulator","title":"Simulateur d'entrée 16 interrupteurs Modicon Quantum 140XSM00200 Schneider Electric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140XSM00200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized diagnostic and commissioning tool within the Schneider Electric Modicon Quantum automation platform. Designed as a high-utility accessory, this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDiscrete Input Simulator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 16 integrated manual switches that allow engineers to simulate real-world field signals without the need for external wiring or sensors.\u003c\/p\u003e\n\u003cp\u003eBy plugging directly into the front of specific Quantum discrete input modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140XSM00200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables precise logic validation and Factory Acceptance Testing (FAT). It is an essential component for debugging complex PLC code, verifying interlock sequences, and training operators in a risk-free environment. This \"dry-run\" capability ensures that automation logic is fully vetted before the system is connected to live industrial machinery, significantly reducing the risk of equipment damage during startup.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 140XSM00200 is engineered for seamless mechanical and functional integration with the Quantum I\/O lineup:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Simulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides 16 independent toggle switches, allowing for the simultaneous simulation of a full 16-point input module's data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed to interface with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DAI54000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(115 VAC) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DAI74000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(230 VAC) discrete input modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Hardware Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMounts directly onto the front connector of the target I\/O module, overriding field inputs to provide manual control to the technician.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNo External Power Required:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe simulator utilizes the internal logic of the module it is connected to, requiring no additional external power source for signal injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Visibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe manual switch positions provide an immediate physical reference for the state of each input bit, mirroring the status LEDs on the host module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140XSM00200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Quantum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccessory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Input Simulator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Switches\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140DAI54000, 140DAI74000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Logic Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual Toggle Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (US)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.51 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e00785901652083\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 140XSM00200 require separate software configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The PLC CPU treats the simulator exactly like the field signals it replaces. In your programming environment (Unity Pro\/Control Expert), you simply monitor the discrete input registers associated with the slot where the host module is installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this simulator on 24 V DC modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePer the manufacturer's specifications, the 140XSM00200 is primarily listed for compatibility with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DAI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(AC) series modules. Always verify the connector pinout and voltage rating of the host module before installation to ensure safe operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to leave the simulator installed during normal production?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the simulator is robust, it is intended for testing and maintenance. In a production environment, it should be removed and replaced with actual field wiring to ensure the PLC is receiving real-time data from the process sensors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTesting and Debugging Workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo use the simulator, remove the field wiring connector from the front of your 140DAI module and snap the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140XSM00200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto place. This allows you to \"walk\" through a sequence—for example, toggling Switch 1 for a \"Pump Start\" command and Switch 2 for \"Flow Confirmed\"—to ensure the PLC logic initiates the correct subsequent actions. This is the fastest way to identify \"race conditions\" or logic errors in complex code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe simulator is designed to be user-friendly. When attaching it to a Quantum discrete I\/O module, ensure the pins are correctly aligned with the module's front terminal block. Apply even pressure until the unit is fully seated. Because this is often a US-made component (Country of Origin: US), it adheres to rigorous mechanical tolerances designed for the Quantum \"RAK\" system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStorage and Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince the 140XSM00200 is a diagnostic tool that may not be used every day, store it in an anti-static bag in a clean, dry environment. Periodically cycle the 16 switches while the unit is disconnected to ensure no oxidation builds up on the contacts, which could lead to intermittent signals during your next testing cycle.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573841771,"sku":"140XSM00200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140xsm00200-5un4u2an4nr.png?v=1776159665"},{"product_id":"schneider-electric-tsxmfpp512k-modicon-premium-flash-eprom-memory","title":"Mémoire Flash EPROM Modicon Premium TSXMFPP512K Schneider Electric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXMFPP512K (TSXMFPP512K)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 512 KB Flash EPROM application memory extension card engineered specifically for the Schneider Electric Modicon Premium processor range. This PCMCIA-style memory card serves as a non-volatile storage solution for PLC user programs, symbols, and data constants. By offloading the application logic from volatile RAM to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXMFPP512K\u003c\/strong\u003e, industrial operators ensure that critical control code is preserved even in the event of total power loss or battery failure.\u003c\/p\u003e\n\u003cp\u003eHoused in a compact, ruggedized format, this memory extension is a cornerstone for automation reliability in sectors such as automotive manufacturing, water treatment, and infrastructure management. As a phase-out component, it remains a vital asset for maintaining the longevity of existing Modicon Premium installations and preventing costly system re-engineering.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TSXMFPP512K is designed for seamless hardware integration and high data integrity:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes Flash EPROM technology, allowing for reliable long-term storage without the need for an internal battery for data retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e512 KB Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for standard-to-mid-sized Modicon Premium applications, providing ample space for logic rungs, functional blocks, and system configuration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to fit into the dedicated PCMCIA slot on Modicon Premium TSX57 series processors, enabling rapid memory expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Volatile Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically backs up the application, allowing the processor to perform an automatic \"Warm Start\" or \"Cold Start\" from the Flash card after a power interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand the thermal and electromagnetic stresses common in high-density control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXMFPP512K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlash EPROM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (cm)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 x 13 x 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcessor Memory Extension\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the TSXMFPP512K be used to store data logs or trends?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlash EPROM memory is primarily designed for the application program (code) and system constants. While it provides non-volatile storage, frequent write operations—like high-speed data logging—are better suited for SRAM cards or specialized data storage modules due to the limited write cycles inherent in Flash technology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to insert the memory card while the PLC is powered on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile many PCMCIA cards are designed for rugged use, it is a recommended engineering practice to power down the processor before inserting or removing the TSXMFPP512K. This prevents potential file corruption or electrical transients during the hardware handshake.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the processor RAM and the Flash card contain different programs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a standard configuration, the processor can be set to prioritize the Flash EPROM. Upon power-up, if the processor detects a valid program on the TSXMFPP512K, it will typically load that program into the working RAM, ensuring the machine operates with the verified \"Master\" version of the code.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWrite Protection and Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TSXMFPP512K often features a physical write-protect switch or software-level locking. Once the final commissioning of a project is complete, engineers should enable write protection. This prevents accidental overwriting of the logic by unauthorized users and ensures the integrity of the \"Golden Copy\" of the automation program.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHandling and Static Prevention\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe edge connectors on the PCMCIA card are sensitive to electrostatic discharge (ESD) and contamination. Always handle the card by its edges and avoid touching the gold-plated pins. If the environment is particularly dusty or humid, ensure the processor's slot cover is securely closed after the card is seated to prevent contact oxidation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhase-Out Lifecycle Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince the Modicon Premium range and its associated memory cards like the TSXMFPP512K are in a phase-out status, it is critical to perform regular backups of the Flash contents to a digital repository. In the event of a physical card failure, having a verified file ready for download to a replacement card is the fastest way to restore production.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104573972843,"sku":"TSXMFPP512K","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxmfpp512k-mcs4iilgtfn.png?v=1776164150"},{"product_id":"171ccs78000-schneider-electric-modicon-momentum-m1-processor-adapter","title":"Adaptateur processeur Modicon Momentum M1 171CCS78000 Schneider Electric","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e171CCS78000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance M1 Processor Adapter within the Schneider Electric Modicon Momentum family, engineered to provide centralized intelligence for distributed I\/O topologies. Operating at a clock speed of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 MHz\u003c\/strong\u003e, this processor adapter is designed to snap onto any Momentum I\/O base, transforming a simple I\/O block into a fully functional, programmable logic controller (PLC).\u003c\/p\u003e\n\u003cp\u003eFeaturing dual Modbus communication ports, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e171CCS78000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in multi-device networking, allowing for simultaneous communication with HMI panels, variable speed drives, or supervisory systems. Primarily deployed in manufacturing, water wastewater, and material handling, this module is a critical asset for maintaining legacy industrial systems. Although in its phase-out stage, its proven reliability and deterministic control capabilities make it a vital component for facility managers looking to sustain existing automation footprints without expensive re-engineering.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 171CCS78000 serves as the core \"brain\" for the modular Momentum platform, integrating processing power with flexible networking:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Modbus Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with two independent Modbus RS485 ports, facilitating efficient data exchange and peer-to-peer networking in complex architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20 MHz Processing Core:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivers sufficient computational speed for medium-complexity logic, PID loops, and rapid I\/O refreshing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular \"Snap-On\" Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the need for a backplane; the adapter mounts directly onto I\/O bases, significantly reducing cabinet space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Programming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with Schneider Electric legacy programming software, ensuring seamless logic integration for existing Momentum users.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompact dimensions and a lightweight design (0.22 kg) allow for high-density mounting in small enclosures or distributed junction boxes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e171CCS78000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Momentum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Modbus RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM1 Processor Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out (Legacy Support Available)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (cm)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 x 26 x 6 (Packaged)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 171CCS78000 be used as a standalone controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, when snapped onto a Momentum I\/O base, it functions as a standalone PLC. It does not require a separate rack or power supply module, as it draws power through the I\/O base unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length for the Modbus ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the RS485 Modbus ports, the maximum segment length is 1200 meters (approx. 4000 feet) without a repeater, provided that high-quality shielded twisted-pair cable is used and properly terminated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a direct replacement for this phase-out module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile Schneider Electric has moved toward the Modicon M221\/M241 series, there is no direct \"snap-on\" replacement that fits the Momentum I\/O bases. Maintaining a stock of 171CCS78000 units is the most cost-effective way to support existing Momentum installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Port Wiring and Biasing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen utilizing both Modbus ports, ensure that the network is correctly biased and terminated with 120 Ohm resistors at the physical ends of the trunk. Improper termination on a 20 MHz processor system can lead to intermittent CRC errors and \"Module Health\" alarms. For noise-heavy environments, always use shielded cables and ground the shield at a single point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal and Mounting Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 171CCS78000 mounts directly onto the I\/O base, it relies on the base for structural integrity. Ensure the locking tabs are fully engaged. In high-vibration applications, we recommend additional DIN rail anchors on both sides of the combined assembly. Avoid installing the module in areas with direct sunlight or near high-heat sources, as excessive heat can degrade the 20 MHz oscillator's accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs a legacy M1 adapter, ensure the internal battery or capacitor backup is checked during routine maintenance. If the module is powered down for extended periods without a viable battery, the user program may be lost, requiring a re-download from the original source files.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574005611,"sku":"171CCS78000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/171ccs78000-3lkoukfos1u.png?v=1776159768"},{"product_id":"tsxp57153mc-schneider-electric-modicon-premium-pl7-processor","title":"Processeur PL7 Modicon Premium TSXP57153MC Schneider Electric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57153MC \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, single-format processor belonging to the Schneider Electric Modicon Premium range. Engineered for high-speed industrial logic, this CPU is optimized for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePL7 programming environment\u003c\/strong\u003e, providing a robust solution for medium-to-large scale automation tasks. Operating with a current consumption of 530 mA at 5 V DC, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57153MC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers the deterministic control required for synchronized manufacturing lines, material handling systems, and complex process regulation. Its single-slot format allows for high-density configuration within the Premium rack, maximizing the efficiency of your control cabinet footprint. As a phase-out component, this processor is a critical legacy asset for maintenance teams tasked with sustaining existing infrastructure and ensuring operational continuity without the immediate need for a total system migration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TSXP57153MC is designed to function as the central intelligence of a modular automation system:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically tuned for PL7 software (Junior\/Pro), supporting a wide array of functional blocks, PID control, and floating-point arithmetic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized internal circuitry drawing 530 mA from the rack's 5 V DC backplane, ensuring low thermal dissipation and stable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures integrated ports for Ter\/Aux communication and is compatible with various PCMCIA cards for Modbus, FIPway, or Ethernet connectivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of managing thousands of discrete and analog I\/O points across local and remote racks (via X-Bus or FIPIO).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand industrial vibration and electromagnetic interference, weighing a solid 0.61 kg to ensure mechanical stability within the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXP57153MC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePL7 Junior \/ PL7 Pro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e530 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-Slot (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out (Legacy Support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.61 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (cm)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.00 x 26.00 x 9.50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85371099\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TSXP57153MC compatible with Unity Pro (EcoStruxure Control Expert)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"MC\" designation and its lineage are primarily associated with the PL7 software environment. While some Premium processors can be migrated to Unity Pro, the TSXP57153MC is best utilized as a direct replacement for existing PL7-programmed systems to ensure 100% logic and communication compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this processor include internal memory, or do I need a PCMCIA card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit includes internal RAM for execution, but for non-volatile application storage and backup, a compatible PCMCIA memory card (such as a TSXMRPC or TSXMFPP series) is highly recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot a \"HALT\" light on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA \"HALT\" LED typically indicates a blocking system error or a watchdog timeout. This can be caused by a software loop error, hardware incompatibility, or a failed I\/O module on the bus. Connecting with PL7 software is required to read the system diagnostic buffer for the specific error code.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRack Installation and Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen inserting the TSXP57153MC into a TSXRKY series rack, ensure the power supply is switched off. The single-slot module must be fully seated into the backplane connector before the top and bottom securing screws are tightened. Ensure the rack's grounding terminal is connected to a low-impedance earth bus to protect the 530 mA internal circuitry from high-frequency noise and transients.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMemory and Battery Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TSXP57153MC relies on an internal battery (typically located in the power supply module or the CPU itself depending on the version) to maintain the RAM contents during power-off periods. Since this is a legacy phase-out product, we recommend replacing the battery every 2 years and maintaining a current \"Golden Copy\" of the PL7 application on an external Flash PCMCIA card to prevent data loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Port Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Ter and Aux ports utilize non-isolated RS485 signals. When connecting a PC for programming or an HMI, always use the recommended Schneider Electric shielded cables (e.g., TSXPCX1031). Avoid \"hot-plugging\" communication cables in environments with high potential differences between equipment grounds to prevent damage to the CPU's communication driver.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574071147,"sku":"TSXP57153MC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp57153mc-53g1tlrmgzy.png?v=1776164256"},{"product_id":"schneider-tsxpsi2010-modicon-premium-atrium-power-supply-module","title":"Module d'alimentation Atrium Modicon Premium TSXPSI2010 Schneider","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a specialized 24 VDC power supply module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Premium\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAtrium slot PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. Specifically designed for \"Atrium slot PLC Unity\" configurations, this module provides the critical voltage stabilization and current regulation required to power Atrium processors residing in PC-based automation slots. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a robust electrical interface, shielding sensitive PLC logic from the electrical noise and fluctuations inherent in industrial PC power buses. With a high inrush current tolerance and integrated short-circuit protection via a 2 A time-delay fuse, it ensures that the control system remains operational in demanding environments such as automotive assembly, material handling, and complex machine control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSI2010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware architecture is built for precision power delivery and system safety:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates on a nominal 24 VDC input with a wide tolerance band (19.2 V to 30 V), accommodating standard industrial battery or rectified power sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMicrobreak Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned with internal capacitance to bridge voltage dips of up to 7 ms, preventing system resets during brief power interruptions or supply switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures specialized electrical interfaces including one female\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSUB-D 9\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector and one female\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSUB-D 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector dedicated to the supply voltage input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes an internal 2 A time-delay fuse to protect against overcurrent and short-circuits, alongside high immunity to inrush currents (100 A at 25 deg C).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtrium Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eForm-factored to integrate seamlessly with Atrium slot PLC architectures, providing the \"Unity\" compatible power layer for PC-integrated safety and control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXPSI2010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium \/ Atrium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.2 to 30 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 1.1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 A at 25 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A Fuse (Time Delay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSUB-D 9 and SUB-D 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAltitude Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 2000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TSXPSI2010 compatible with standard Modicon Premium RKY racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific model is designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAtrium slot PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. Standard Modicon Premium racks typically use the TSXPSY series (e.g., TSXPSY2600). The TSXPSI2010 is intended for the PC-based slot-PLC versions of the Modicon architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle brief power losses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module has an immunity to microbreaks of up to 7 ms at 24 V. If the supply voltage drops for a duration shorter than this, the internal energy storage maintains the processor's operation without a system halt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of cabling is required for the SUB-D 3 connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SUB-D 3 connector is used for the primary 24 VDC supply input. It is critical to use properly shielded, twisted-pair cabling to minimize EMI and ensure that the \"Unity\" software diagnostics for power health remain accurate.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current Planning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen sizing your 24 VDC bulk power supply, account for the 100 A inrush current of the TSXPSI2010. While this spike lasts only milliseconds (3 A²s), a power supply with overly sensitive \"electronic fuse\" trip settings may fail to start.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the industrial PC or enclosure housing the Atrium slot PLC has adequate airflow. The TSXPSI2010 is rated for operation up to 60 deg C; however, if the PC's internal ambient temperature exceeds this due to high CPU load, the power supply module's lifespan may be reduced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SUB-D connectors must be securely tightened to the chassis. The metal shell of the SUB-D connector provides the necessary path to ground for electromagnetic interference. A loose connector can lead to intermittent \"I\/O Fault\" or \"Power Supply Fault\" LEDs on the Atrium processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the module fails to power up, check the internal 2 A time-delay fuse. Always replace it with an identical rating (IEC 1131-2 compliant) to maintain the safety certification and protective characteristics of the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574169451,"sku":"TSXPSI2010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxpsi2010-vcvnyoydkty.png?v=1776164428"},{"product_id":"schneider-ls1d253a65-tesys-fuse-disconnector-body-3p-25a","title":"Corps de disjoncteur fusible TeSys (3P, 25A) LS1D253A65 Schneider","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eLS1D253A65\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003eis a robust 3-pole fuse-disconnector body from the Schneider Electric\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTeSys LS1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erange.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis high-reliability isolation device is specifically designed for the protection and manual disconnection of industrial electrical circuits.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt accommodates\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e10 x 38 mm NFC\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efuses (AM or GG types) and features an integrated signaling circuit with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e2 C\/O early-break auxiliary contacts\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThese auxiliary contacts provide essential feedback to control systems or safety interlocking circuits before the main power poles open.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for extreme environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe LS1D253A65 operates in temperatures ranging from\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e-50 to 70 deg C\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it an ideal choice for outdoor control panels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erefrigeration systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand heavy-duty industrial motor protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eLS1D253A65\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built for high-performance circuit isolation and safety signaling:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e3-Pole Isolation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides simultaneous disconnection of all three phases in a compact 94 mm width footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEarly-Break Contacts:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with 2 C\/O (Changeover) early-break auxiliary contacts.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThese contacts toggle before the main power circuit opens,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing the control system to safely ramp down loads or trigger alarms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFuse Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for standard 10 x 38 mm NFC fuses,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting both motor-rated (AM) and general-purpose (GG) fuse links.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMechanical Operation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a high-visibility toggle control for manual operation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith a mounting tolerance of +\/- 23 degrees from the vertical position.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh Voltage Rating:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRated for operational voltages up to 690 V AC for the power circuit and 500 V AC \/ 440 V DC for the signaling circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLS1D253A65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (TeSys)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3P (3 Poles)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFuse Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 x 38 mm (NFC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 A (Power) \/ 10 A (Signaling)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e690 V AC (Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAuxiliary Contacts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 C\/O Early-Break\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-50 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 mm x 94 mm x 84 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of \"Early-Break\" auxiliary contacts in this device?\u003c\/strong\u003eEarly-break contacts are a safety feature. They change state slightly before the main poles disconnect. This allows a PLC or safety relay to detect the disconnection intent and electronically shut down sensitive components (like variable speed drives or motor contactors) to prevent arcing across the main disconnector poles under load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this disconnector for DC power circuits?\u003c\/strong\u003eThe power circuit rating is specified for 690 V AC. While the signaling circuit is rated for 440 V DC, using the main poles for high-current DC disconnection requires specific de-rating and verification of the arc-extinguishing capabilities for DC. It is primarily intended for AC motor and distribution circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit come with fuses included?\u003c\/strong\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLS1D253A65\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a fuse-disconnector\u003cspan\u003e \u003c\/span\u003e\u003cem\u003ebody\u003c\/em\u003e. The 10 x 38 mm fuses must be selected and purchased separately based on the specific current and protection characteristics (AM or GG) required for your load.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-221\"\u003e\u003c\/span\u003e\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e\u003cspan class=\"citation-221 citation-end-221\"\u003e\u003cspan\u003e \u003c\/span\u003eThe device is designed for vertical mounting on a standard 35 mm DIN rail.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the mounting position stays within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+\/- 23 degree\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etolerance to ensure the mechanical toggle operates correctly and the fuse carriers remain secure.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring the Signaling Circuit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the 2 C\/O auxiliary contacts to interlock the disconnector with your upstream contactor. This ensures that the circuit is de-energized by a contactor capable of breaking the full load current before the manual disconnector is opened.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"TH\" protective treatment makes this device suitable for humid environments. However, in extreme cold (-50 deg C), ensure the toggle is operated slowly to prevent mechanical stress on the housing until the internal cabinet temperature stabilizes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure fuses are fully seated in the carrier before closing the toggle. A loose fuse can cause localized heating and high resistance, leading to premature failure of the terminal base or the fuse itself.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574234987,"sku":"LS1D253A65","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ls1d253a65-mgkxzdwitmi.png?v=1776163251"},{"product_id":"schneider-modicon-premium-tsxp57024m-processor","title":"Processeur Modicon Premium TSXP57024M Schneider","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57024M\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a standard-format processor within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Premium\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautomation platform, engineered for high-speed industrial control and flexible distributed I\/O management. Positioned as a versatile mid-range CPU, it provides a discrete I\/O capacity of up to 1024 points and supports up to 80 analog channels. Its architecture is optimized for mid-to-large scale applications in manufacturing, water treatment, and infrastructure, offering a deterministic execution environment with 48 Kwords of internal memory. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57024M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in communication versatility, featuring integrated terminal and auxiliary ports for HMI or programming access, alongside a PCMCIA slot for high-level fieldbus integration like Modbus+, FIPIO, or RS 485.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57024M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware is designed for modular scalability and high-performance processing:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with 48 Kwords of internal memory (K16), with support for extension memory up to 128 Kwords via PCMCIA cards for extensive data logging and complex logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManages up to 16 racks (4\/6\/8-slot) or 8 racks (12-slot), providing access to a total of 96 physical module slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures two 8-pin mini-DIN connectors (non-isolated RS 485):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTER Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupplies 5V for FTX terminals or PCs; defaults to UNI-TELWAY master at 19200 bauds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAUX Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDedicated for MMI (Man-Machine Interface) or printers; does not supply power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecific Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports 24 application-specific channels (e.g., high-speed counting or motion) and up to 4 AS-i bus masters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePCMCIA Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe front-panel Type 3 slot accepts multiprotocol cards including TSX SCP 111 (RS 232), TSX MBP 100 (Modbus+), and TSX MDM 10 (Modem).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXP57024M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1024 In-rack I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 In-rack I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 Kwords (K16)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTER and AUX (RS 485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard (Single-slot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUNI-TELWAY, ASCII, FIPIO, Modbus+\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn which slot should I install the TSXP57024M standard format processor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe installation position depends on your power supply. If using a standard power supply (TSX PSY 1610\/2600), the processor is preferred in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eposition 00\u003c\/strong\u003e. If using a double-format power supply (TSX PSY 3610\/5500), the processor must be installed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eposition 01\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the TER and AUX ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both are RS 485 mini-DIN connectors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTER port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 5V power to peripheral devices like handheld terminals or RS-232\/485 converters. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAUX port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis strictly for data and is typically used for HMI or printers that have their own power source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I hot-swap the PCMCIA communication card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The documentation strictly mandates that the processor must be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOWERED DOWN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprior to inserting or removing any PCMCIA communication or memory card to prevent electronic damage or system crashes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Mounting Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXP57024M\u003c\/strong\u003e, ensure the locking levers are fully clicked into place. The rack power supply must always be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOWERED DOWN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring insertion to avoid arcing across the backplane pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf your application requires more than 48 Kwords, utilize the PCMCIA extension slot. Always verify the battery status of the PCMCIA card (if applicable) to ensure data persistence during a system power cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing for Mini-DIN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TER and AUX ports use fragile 8-pin connectors. Use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSX P ACC 01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eisolation box for long-distance UNI-TELWAY connections to provide surge protection and signal isolation between the PLC and the network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration and Thermal Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the rack horizontally to allow for natural heat convection. Maintain at least 100 mm of clearance above and below the module to keep the operating temperature within the rated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 60 deg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574267755,"sku":"TSXP57024M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp57024m-qkxl0wlhqhs.png?v=1776164236"},{"product_id":"schneider-electric-atv212wu22n4c-altivar-212-variable-frequency-drive","title":"Variateur de fréquence Altivar 212 ATV212WU22N4C Schneider Electric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-906\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eATV212WU22N4C (ATV212WU22N4C)\u003c\/strong\u003e\u003cspan class=\"citation-906 citation-end-906\"\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated HVAC variable frequency drive (VFD) optimized for pumping, ventilation, and air conditioning applications.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-905 citation-end-905\"\u003eEngineered for high-reliability performance in building management systems (BMS), this 2.2 kW controller operates at 480 V (3-phase) and features an integrated EMC Class C1 filter to minimize electromagnetic interference.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-904\"\u003eWith its robust\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIP55\u003c\/strong\u003e\u003cspan class=\"citation-904 citation-end-904\"\u003e\u003cspan\u003e \u003c\/span\u003eprotection rating, the unit is designed for decentralized installation outside of electrical cabinets, providing superior resistance against dust and water jets.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis drive is a critical component for facility managers looking to reduce energy consumption by up to 70% while maintaining precise control over flow and pressure in commercial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-903 citation-end-903\"\u003eThe Altivar 212 architecture is focused on \"Eco-Design\" and seamless integration into building automation networks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt eliminates the need for additional harmonic filters in most applications due to its reduced capacitance technology, which limits current distortion to less than 35% THD(i). The drive supports multi-protocol communication, including Modbus, METASYS N2, APOGEE FLN, and BACnet as standard. Its IP55 enclosure is specifically thermal-mapped to ensure high-efficiency cooling without the need for external ventilation, making it ideal for rooftop or mechanical room deployments where space and protection are paramount.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATV212WU22N4C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAltivar 212\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 kW (3 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380-480 V (3-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP55 \/ UL Type 12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEMC Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass C1 (Integrated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.26 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36.5 x 25.5 x 28.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus, BACnet, METASYS N2, APOGEE FLN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to +40 deg C (up to 50 deg C with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ATV212WU22N4C require an external enclosure for outdoor use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the IP55 rating indicates the drive is protected against dust ingress and low-pressure water jets from any direction. It can be mounted directly on the wall or machine frame, provided it is shielded from direct sunlight and extreme precipitation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the Altivar 212 and the Altivar 320 or 630?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-902 citation-end-902\"\u003eThe Altivar 212 is specifically \"HVAC-optimized.\"\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-901 citation-end-901\"\u003eIt lacks the high-torque features required for heavy industrial machinery (like conveyors) but includes specialized software functions for fans and pumps, such as \"Fire Mode,\" \"Sleep\/Wake,\" and \"Damper Control.\"\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used with single-phase input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the ATV212WU22N4C is strictly designed for 3-phase input. Attempting to run the drive on single-phase power will result in an input phase loss fault (PHF) and may damage the DC bus capacitors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonic Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard industrial drives, the ATV212 utilizes a specialized DC bus design that inherently reduces harmonics. You generally do not need to install line reactors to meet IEEE 519 standards in building applications, which saves significant installation space and cost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the EMC Class C1 rating, use shielded motor cables. Ensure the shield is bonded 360 degrees to the drive's grounding plate. For IP55 units, use appropriate liquid-tight cable glands to maintain the enclosure's integrity at the entry points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEven with an IP55 rating, thermal management is vital. Maintain at least 10 cm of vertical clearance above and below the unit. If mounting multiple drives side-by-side, ensure a minimum horizontal gap of 5 cm to allow for natural convection cooling across the heat sink fins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574529899,"sku":"ATV212WU22N4C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv212wu22n4c-zaei55mg52t.png?v=1776162217"},{"product_id":"schneider-170adm69051-modicon-momentum-discrete-i-o-base-10i-8o","title":"Base E\/S discrètes Modicon Momentum 170ADM69051 Schneider","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-110\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-110\"\u003eis a high-performance discrete triac I\/O base within the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eModicon Momentum\u003c\/strong\u003e\u003cspan class=\"citation-110 citation-end-110\"\u003e\u003cspan\u003e \u003c\/span\u003eautomation platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-109\"\u003eDesigned for distributed control architectures, this module features a 120 V AC interface with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e10 inputs\u003c\/strong\u003e\u003cspan class=\"citation-109\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8 triac outputs\u003c\/strong\u003e\u003cspan class=\"citation-109 citation-end-109\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-108 citation-end-108\"\u003eThe Momentum platform’s unique modular design allows this base to be paired with various communication adapters (Ethernet, Modbus, Profibus) or a processor adapter, making it a highly versatile solution for decentralized automation.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWith its solid-state triac outputs and robust 120 V AC logic, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for controlling AC loads such as solenoids, contactors, and motor starters in HVAC, water treatment, and manufacturing applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-107\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003c\/strong\u003e\u003cspan class=\"citation-107 citation-end-107\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for industrial-grade AC switching and signal processing:\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-106\"\u003e\u003c\/span\u003e\u003cstrong\u003eI\/O Density:\u003c\/strong\u003e\u003cspan class=\"citation-106 citation-end-106\"\u003e\u003cspan\u003e \u003c\/span\u003eConfigured with one group of 10 digital inputs (IEC 1131-2 Type 2) and one group of 8 digital triac outputs.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePositive logic with a 120 V AC nominal rating. It features a high guaranteed \"On\" state voltage (\u0026gt; 74 V) to ensure immunity against induced electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-State Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriac-based outputs provide long-cycle life compared to mechanical relays, supporting a high operating rate of up to 3,000 cycles per hour.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-105\"\u003e\u003c\/span\u003e\u003cstrong\u003eInternal Protection:\u003c\/strong\u003e\u003cspan class=\"citation-105 citation-end-105\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with two internal 2.5 A slow-blow fuses to protect the module from overcurrent conditions in the output groups.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a high dielectric strength of 1780 V AC between the field channels and the internal communication bus to safeguard the controller electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170ADM69051\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Momentum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 V AC (74...132 V range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriac (Solid State)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per point (4 A total per module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2 line cycle (approx. 8ms at 60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 W to 8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e141.5 mm x 125 mm x 47.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of a Triac output over a relay output for the 170ADM69051?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-104 citation-end-104\"\u003eTriacs are solid-state devices with no moving parts.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThey are preferred for high-frequency switching (up to 3000 cyc\/h) because they do not suffer from contact wear or arcing, which significantly extends the life of the module in repetitive industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle 24 V DC signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-103\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003c\/strong\u003e\u003cspan class=\"citation-103 citation-end-103\"\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for 120 V AC voltage levels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eUsing DC voltage on the inputs or outputs will lead to a failure to switch (in the case of Triacs) or incorrect signal states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if an output is short-circuited?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-102 citation-end-102\"\u003eThe module contains internal 2.5 A slow-blow fuses.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of an overcurrent or short circuit that exceeds the rating, the fuse will blow to protect the internal circuitry. Note that these fuses protect groups of outputs rather than individual points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriac outputs require a minimum holding current to stay in the \"On\" state. For the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170ADM69051\u003c\/strong\u003e, ensure your load draws at least 30 mA. If using very small pilot lights or high-impedance relays, a bleeder resistor may be required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLeakage Current Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSolid-state outputs have a small leakage current (\u0026lt; 1.3 mA at 120 V) when in the \"Off\" state. Verify that your field device will not remain energized or \"ghost\" due to this leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting \u0026amp; Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Momentum base should be snapped securely onto a 35 mm DIN rail. Ensure the grounding leaf spring on the back of the module makes clean contact with the metal rail to ensure proper EMC performance and ESD resistance (up to 8 kV air discharge).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen operating at the maximum current of 4 A per module at 60 deg C, ensure adequate cabinet ventilation. The module dissipates up to 8 W of heat; vertical mounting is recommended to facilitate natural convection through the cooling vents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574562667,"sku":"170ADM69051","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/170adm69051-alti2czhxth.png?v=1776159707"},{"product_id":"schneider-tsxp57303amc-modicon-premium-double-format-pl7-processor","title":"Processeur double format PL7 Modicon Premium TSXP57303AMC Schneider","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTSXP57303AMC\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a high-performance,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edouble-format processor belonging to the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eModicon Premium\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eautomation platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for mid-to-high complexity industrial applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis processor utilizes\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePL7 Junior\/Pro\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esoftware to manage sophisticated control logic.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith a robust discrete I\/O capacity of up to 1024 points and specialized support for up to 45 process control loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TSXP57303AMC is a staple in sectors like water treatment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efood and beverage,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand infrastructure management.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"double-format\" module occupies two slots on the Premium rack,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the necessary hardware overhead for high-speed Boolean execution (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e12 µs) and extensive network connectivity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding support for CANopen,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAS-Interface,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand multiple fieldbus modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTSXP57303AMC\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for versatility and rapid processing in distributed architectures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMemory Management:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures 64 Kwords of internal RAM for program and data.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMemory is expandable via PCMCIA cards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting up to 384 Kwords for programs and 2688 Kwords for additional data storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMultitasking Capability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports an advanced application structure consisting of one master task,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eone fast task,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand 64 event-triggered tasks for prioritized response to critical field signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Communication:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIncludes a non-isolated serial link (Mini-DIN) supporting speeds up to 115 kbit\/s.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt can manage up to 3 network modules and 2 fieldbus modules simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePerformance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDelivers high-speed instruction execution,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereaching up to 6.\u003c\/span\u003e\u003cspan class=\"\"\u003e57 Kinst\/ms for 100% Boolean logic without an external PCMCIA card.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic LEDs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with local signaling for system status:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eRUN\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e(Green),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eI\/O\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efault (Red),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eERR\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esystem fault (Red),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTER\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eterminal port activity (Yellow).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXP57303AMC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePL7 Junior \/ PL7 Pro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1024 I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExecution Time (Boolean)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 µs (Internal RAM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 mA at 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDouble-format (occupies 2 slots)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg (1.15 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes the TSXP57303AMC require a battery for memory retention?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe processor uses internal RAM which requires a backup battery (typically located in the rack power supply or on the processor itself) to retain the program and data object areas (%MW) during power outages.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor permanent storage,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ea PCMCIA Flash memory card is recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I use Unity Pro \/ EcoStruxure Control Expert with this processor?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eTSXP57303AMC\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePL7\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esoftware environment.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile some Modicon Premium processors can be upgraded to Unity Pro,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis specific AMC variant is optimized for legacy PL7 Junior and Pro applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the maximum number of racks this processor can manage?\u003c\/strong\u003e\u003cspan class=\"\"\u003eIt can support up to 16 racks if using 4,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e6,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor 8-slot configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor up to 8 racks when using 12-slot racks,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for a total of 128 slots across the architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSlot Placement:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs a double-format module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TSXP57303AMC must be placed in the first two slots of the TSXRKY rack (Slots 0 and 1).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the rack power supply (TSXPSY) is rated to handle the 1000 mA draw of the processor plus all associated I\/O modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Management:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the 0 to 60 deg C operating range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensure a minimum clearance of 100 mm above and below the rack.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe processor is treated with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eHumiseal 1A33 conformal coating\u003c\/strong\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e providing enhanced resistance to humidity and chemical contaminants (Pollution Degree 2).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePCMCIA Card Handling:\u003c\/strong\u003e\u003cspan\u003e Only insert or remove PCMCIA memory or communication cards when the processor is powered down or in a \"STOP\" state to avoid data corruption.\u003c\/span\u003e\u003cspan\u003e Ensure the locking latch is fully engaged to prevent vibration-induced disconnects.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e Ensure the TSXRKY rack is bonded to a low-impedance functional earth.\u003c\/span\u003e\u003cspan\u003e The processor's shielding and noise immunity depend heavily on the integrity of the rack's grounding strip.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574595435,"sku":"TSXP57303AMC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsxp57303amc-vupvaloc0zk.png?v=1776164316"},{"product_id":"schneider-170xts00200-modicon-momentum-quantum-spring-terminal-block","title":"Bloc de jonction à ressort Modicon Momentum\/Quantum 170XTS00200 Schneider","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200 (170XTS00200)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance spring-type terminal block accessory designed for the Schneider Electric Modicon Momentum and Modicon Quantum automation platforms.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunctioning as a primary connection interface,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis terminal block enables the rapid and secure integration of field wiring with discrete and analog I\/O bases.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing advanced spring-clamping technology,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the risk of terminal loosening caused by industrial vibration or thermal expansion—common issues with traditional screw-type connectors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis reliability makes it an essential component for critical infrastructure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eautomotive assembly lines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand high-vibration power generation environments where maintaining electrical continuity is vital for system uptime.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for high-density wiring and long-term mechanical stability:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSpring Terminal Technology:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides a constant,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaintenance-free clamping force on field conductors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reducing commissioning time compared to screw terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCompatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with both Modicon Momentum I\/O bases and Modicon Quantum automation platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModular Composition:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupplied as a kit containing three connectors arranged in a single row,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eperfectly aligned for high-density I\/O modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConnection Versatility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports a wide range of wire gauges,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eaccommodating single conductors up to 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm² or dual-conductor configurations up to 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm².\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConstructed from heavy-duty,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eflame-retardant materials designed to withstand the rigors of control cabinet environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170XTS00200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric (Modicon)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccessory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpring Terminal Block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpring Clamping \/ Tool-less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Momentum \/ Modicon Quantum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Destination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete and Analog I\/O Bases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClamping Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 2.5 mm² to 2 x 1.5 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKit Composition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Connectors in one row\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95.000 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (HxWxL)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 mm x 16 mm x 90 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 Months\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat are the primary benefits of using spring terminals over screw terminals?\u003c\/strong\u003e\u003cspan class=\"\"\u003eSpring terminals provide superior vibration resistance.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile screw terminals can back out over time due to mechanical harmonics,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe spring mechanism in the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eapplies constant pressure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring a gas-tight connection that never requires re-torquing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIs this terminal block compatible with third-party I\/O modules?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e170XTS00200\u003c\/strong\u003e\u003cspan\u003e is specifically keyed and dimensioned for Schneider Electric’s Modicon Momentum and Quantum series I\/O bases.\u003c\/span\u003e\u003cspan\u003e Using it with non-compliant hardware may lead to poor electrical contact or physical damage to the module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the kit include enough connectors for a full I\/O base?\u003c\/strong\u003e\u003cspan\u003eThe kit contains three connectors in one row.\u003c\/span\u003e\u003cspan\u003e Depending on the specific Modicon Momentum or Quantum module being used,\u003c\/span\u003e\u003cspan\u003e you may require multiple kits to populate the entire I\/O interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Preparation:\u003c\/strong\u003e\u003cspan\u003e For optimal conductivity and ease of insertion,\u003c\/span\u003e\u003cspan\u003e it is highly recommended to use wire-end ferrules on all stranded conductors.\u003c\/span\u003e\u003cspan\u003e This prevents fraying and ensures the spring clamp engages the full cross-section of the wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsertion Technique:\u003c\/strong\u003e\u003cspan\u003e Use a small flat-head screwdriver or a dedicated terminal tool to depress the spring actuator.\u003c\/span\u003e\u003cspan\u003e Insert the wire into the open cavity and release the tool to lock the conductor in place.\u003c\/span\u003e\u003cspan\u003e Tug gently on the wire to verify a secure mechanical bond.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Management:\u003c\/strong\u003e\u003cspan\u003e In environments with extreme mechanical oscillation (e.\u003c\/span\u003e\u003cspan\u003eg.,\u003c\/span\u003e\u003cspan\u003e near large motors or compressors),\u003c\/span\u003e\u003cspan\u003e ensure that field cables are appropriately strain-relieved before they reach the terminal block.\u003c\/span\u003e\u003cspan\u003e This prevents external mechanical stress from pulling against the spring mechanism.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLabeling Protocol:\u003c\/strong\u003e\u003cspan\u003e Utilize the space above the connectors for clear channel identification.\u003c\/span\u003e\u003cspan\u003e Because spring terminals allow for very high wiring density,\u003c\/span\u003e\u003cspan\u003e accurate labeling is critical for reducing troubleshooting time during maintenance cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104574628203,"sku":"170XTS00200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/170xts00200-k4e3fo0yps5.png?v=1776159749"}],"url":"https:\/\/www.plcprotech.com\/fr\/collections\/schneider-electric.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}