{"product_id":"060g2049-danfoss-aks-33-heavy-duty-pressure-transmitter","title":"060G2049 Transmetteur de pression robuste Danfoss AKS 33","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2049 (060G2049)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision AKS 33 pressure transmitter specifically engineered for high-demand refrigeration and air conditioning applications. Part of the elite Danfoss Sensors group, this current-output transmitter converts measured pressure into a standard 4-20 mA signal, ensuring reliable data transmission even over long cable runs with high electromagnetic interference. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAKS 33\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to thrive in extreme industrial climates, handling medium temperatures from -40 to 85 deg C. Its sealed gauge reference and 33 bar overload capacity make it a critical component for monitoring suction and discharge pressures in commercial refrigeration racks, process cooling systems, and heavy-duty heat pumps where accuracy and long-term stability are non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 060G2049 utilizes a specialized piezo-resistive sensing element paired with advanced internal compensation electronics. Unlike standard sensors, this model is specifically tuned for a compensated temperature range of -30 to 40 deg C, making it ideal for low-temperature refrigeration environments where thermal drift must be minimized. The electrical interface complies with the EN 175301-803-A (DIN Large B) standard, utilizing an angular connector that provides an IP65 protection rating against dust and moisture ingress. The \"Sealed Gauge\" pressure reference ensures that the internal sensor remains protected from atmospheric humidity and corrosive ambient air, maintaining a consistent zero point regardless of external environmental changes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAKS 33 (060G2049)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (2-Wire Current Loop)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Reference\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealed Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33 bar (479 psi) Max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 175301-803-A Angular Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedium Temp Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temp Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompensated Temp Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 40 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.152 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I wire the 060G2049 for a standard PLC analog input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter operates on a 2-wire 4-20 mA loop. Connect the positive supply (typically 9-32 VDC) to Terminal 1 and the signal return to Terminal 2 of the angular connector. Terminal 3 is generally unused or connected to the shield\/ground depending on your cabinet grounding scheme.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the compensated temperature range of -30 to 40 deg C important?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific range is optimized for suction line monitoring in refrigeration. Within this window, the transmitter applies active corrections to eliminate errors caused by temperature fluctuations, ensuring the pressure reading remains accurate even when the sensor body is subjected to extreme cold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum pressure this sensor can withstand without failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 060G2049 can handle an overload pressure of up to 33 bar (479 psi). Exceeding this limit may cause permanent deformation of the sensing diaphragm or lead to a calibration shift, requiring the replacement of the unit.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMoisture and Condensation Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn low-temperature applications, condensation often forms on the sensor body. To maintain the IP65 seal, ensure the angular connector is oriented downwards so that water can drip off. Use a \"drip loop\" in the electrical cable to prevent moisture from being funneled directly into the connector housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVibration and Pulsation Damping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the transmitter is installed near a reciprocating compressor or high-velocity valve, it may be subject to pressure spikes and mechanical vibration. To extend the service life of the 060G2049, install it on a short capillary tube or use a damping orifice (snubber) to isolate the piezo-resistive element from high-frequency hydraulic shock.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Power Calculation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure your DC power supply can handle the loop resistance. The minimum voltage at the transmitter terminals must be 9 VDC when the signal is at its 20 mA peak. Account for the voltage drop across the cable and the input impedance of your PLC or controller to ensure stable signal performance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102413381995,"sku":"060G2049","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g2049-or2jr5sgkuv.png?v=1776136923","url":"https:\/\/www.plcprotech.com\/fr\/products\/060g2049-danfoss-aks-33-heavy-duty-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}