{"product_id":"060g2050-danfoss-aks-33-pressure-transmitter-current-output","title":"Transmetteur de pression AKS 33 - Sortie courant Danfoss 060G2050","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2050 (060G2050)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance pressure transmitter from the Danfoss AKS 33 series, specifically engineered for refrigeration and air conditioning applications. Optimized for precision and stability, this sensor converts pressure into a standardized 4-20 mA current signal, ensuring reliable long-distance data transmission even in environments with high electromagnetic interference. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2050\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a sealed gauge pressure reference and a robust design capable of withstanding media temperatures from -40 to 85 Celsius. Whether integrated into commercial chillers or industrial cooling racks, this transmitter provides the critical feedback necessary for energy-efficient evaporator and condenser control, significantly reducing the risk of system failures and compressor stress.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2050\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for seamless integration into advanced HVAC and refrigeration control loops:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealed Gauge Reference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a stable pressure reference that is isolated from atmospheric pressure fluctuations, ensuring consistent readings in all climate conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Current Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output signal is highly resistant to voltage drops across long cable runs, making it the preferred choice for large-scale industrial installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Thermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an electronically compensated temperature range from 0 to 80 Celsius, maintaining signal accuracy despite varying ambient conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Electrical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with an EN 175301-803-A angular connector (DIN plug), providing a secure, IP65-rated connection that simplifies field replacement and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G2050 (Type AKS 33)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA Current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealed Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Pressure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 bar (580 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 175301-803-A Angular Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMedium Temp. Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompensated Temp.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 80 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.152 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the current output benefit refrigeration control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 4-20 mA signal produced by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e084G2050\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis inherently immune to electrical noise and line resistance. Unlike voltage-based sensors, the current signal remains constant regardless of the cable length, ensuring that the controller receives an exact pressure reading even if the sensor is located far from the electrical panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the AKS 33 compatible with ammonia (R717)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the AKS 33 series is designed to be compatible with most common refrigerants, including ammonia and halogenated refrigerants. Its stainless steel construction ensures resistance to chemical corrosion common in industrial cooling systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Sealed Gauge\" reference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA sealed gauge reference uses an internal vacuum or set pressure as a baseline. This prevents the sensor from being affected by changes in barometric pressure due to altitude or weather, which is essential for maintaining accuracy in high-pressure refrigeration cycles.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration and Pulse Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure maximum sensor longevity, mount the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2050\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon a vibration-damped bracket rather than directly on a reciprocating compressor. If the system is prone to liquid hammer or high-frequency pulses, install a capillary tube or a pressure snubber between the pipe and the transmitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connection Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the angular connector (EN 175301-803-A), ensure the rubber gasket is correctly seated before tightening the central screw. This is critical to achieving the IP65 rating and preventing moisture from corroding the electrical pins in humid mechanical rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for 4-20 mA Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the power supply is between 9 and 32 VDC. Always use shielded, twisted-pair cabling for signal lines and ground the shield at the controller end only to prevent ground loops that could distort the 0.5% typical accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416200043,"sku":"060G2050","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g2050-rucpj1qmt4i.png?v=1776136925","url":"https:\/\/www.plcprotech.com\/fr\/products\/060g2050-danfoss-aks-33-pressure-transmitter-current-output","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}