{"product_id":"060g2110-danfoss-aks-33-heavy-duty-pressure-transmitter","title":"Transmetteur de pression robuste AKS 33 Danfoss 060G2110","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2110 (060G2110)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability pressure transmitter from the Danfoss AKS 33 series, specifically optimized for refrigeration and air conditioning control systems. This industrial-grade sensor converts process pressure into a standardized 4-20 mA current signal, facilitating accurate and stable data transmission over long distances without signal degradation. Engineered to perform in extreme thermal conditions, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates effectively within a medium temperature range of -40 to 85 deg C. Its sealed gauge reference design ensures that pressure readings remain independent of barometric fluctuations, making it a critical component for maintaining precision in high-capacity chillers, commercial food storage, and industrial cooling racks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for seamless integration into high-performance automation loops:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Current Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output provides high immunity to electrical noise, ensuring consistent performance in mechanical rooms with high electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealed Gauge Reference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing a factory-set internal reference pressure, the sensor delivers accurate relative pressure data regardless of local altitude or atmospheric changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Electrical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with an EN 175301-803-A (DIN) angular connector, the unit offers a secure, vibration-resistant connection with an IP65 enclosure rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes active electronic compensation for temperatures between 0 and 80 deg C, minimizing thermal drift and ensuring signal linearity across varying seasonal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G2110 (Type AKS 33)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA Current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealed Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Pressure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 bar (580 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAngular Connector (EN 175301-803-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMedium Temp. Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.168 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the current signal benefit large-scale HVAC installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe current signal of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for cable runs of hundreds of meters without voltage drop issues. This is essential in large commercial buildings where the sensor is located on a rooftop condenser while the main PLC cabinet is several floors below.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 060G2110 be used with Ammonia (R717) or CO2 (R744)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AKS 33 series is designed for compatibility with most common refrigerants, including HFC, HCFC, and Ammonia. For CO2 applications, ensure the 40 bar overload rating and the specific operating range match your system's transcritical or subcritical pressures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the response time of the AKS 33 sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile optimized for stability, the AKS 33 features a fast internal response time (typically \u0026lt; 4 ms), allowing the controller to react quickly to rapid pressure changes in the suction or discharge lines, which helps in preventing compressor liquid slugging.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulse Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn systems with reciprocating compressors or fast-acting solenoid valves, pressure pulsations can cause mechanical fatigue to the diaphragm. It is recommended to install the transmitter using a capillary tube or a pressure snubber to dampen high-frequency pressure spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealing and Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen attaching the angular connector, verify that the rubber profile gasket is in place. Tighten the central screw to a torque of 0.4 Nm to ensure the IP65 seal is effective against humidity and condensation, which are common in refrigeration environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the 0.5% accuracy, utilize a twisted-pair shielded cable. Connect the shield only at the PLC\/Controller end to avoid creating ground loops, which can introduce offset errors into the 4-20 mA loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416101739,"sku":"060G2110","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g2110-0ozj3vnbrv5.png?v=1776136934","url":"https:\/\/www.plcprotech.com\/fr\/products\/060g2110-danfoss-aks-33-heavy-duty-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}