{"product_id":"084g2107-danfoss-emp-2-series-heavy-duty-pressure-transmitter","title":"Transmetteur de pression robuste série EMP 2 Danfoss 084G2107","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e084G2107 (084G2107)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance pressure transmitter from the renowned EMP 2 series, specifically engineered for demanding industrial and marine applications. Designed to monitor gauge (relative) pressure in systems ranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 6 bar\u003c\/strong\u003e, this unit is a critical component for engine cooling systems, hydraulic power units, and water treatment automation. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e084G2107\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to withstand harsh environmental conditions, offering a typical accuracy of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5% FS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand long-term stability that minimizes maintenance cycles. Its robust terminal block connection and IP65-rated housing ensure reliable signal transmission even in high-vibration or high-moisture environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e084G2107\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures the EMP 2 series' signature heavy-duty design, utilizing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG 1\/2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epressure connection (standard EN 228-1) with an internal G 1\/4 interface for maximum mounting flexibility. Unlike flush-diaphragm models, this transmitter uses a standard pressure port optimized for clean or filtered liquids and gases. The electrical interface is managed via a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePg 13.5\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block, allowing for secure field wiring of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutput loop. To ensure precision across varying climates, the device includes an internal compensated temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 70 deg C\u003c\/strong\u003e, which effectively filters out thermal-induced signal drift.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e084G2107\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification Key\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEMP 2-1811-F6CD24-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 6 bar (0 to 87.02 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Reference\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 % FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/2 Male \/ G 1\/4 Female\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 ms (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg (Approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the wiring designations for the terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 084G2107 uses a standard two-wire current loop configuration. Connect the positive DC supply to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal (+ supply) and the return\/common to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal (- common).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 18 bar overload pressure rating benefit my system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 18 bar rating provides a safety margin three times higher than the operating range (6 bar). This protects the internal sensing element from permanent damage or calibration shifts caused by sudden hydraulic surges or pressure spikes during system start-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter be used in seawater or corrosive chemical applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EMP 2 series is generally built for durability; however, always verify that the wetted parts (G 1\/2 stainless steel or alloy) are compatible with your specific medium. For highly corrosive acids, a chemical seal or isolated barrier may be required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the Pg 13.5 cable gland to ensure a watertight seal. When stripping wires for the terminal block, ensure no stray strands are protruding, as the compact spacing within the EMP 2 housing can lead to short circuits under high-vibration conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Dampening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn marine engine or pump room installations, mount the transmitter on a bracket that is mechanically isolated from the primary vibration source. While the unit is rated for industrial use, constant high-frequency resonance can cause micro-fatigue in the internal electronics over several years of service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVenting and Pressure Reference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this is a Gauge (Relative) pressure transmitter, ensure the internal reference port (located near the electrical entry) is not blocked by paint, grease, or heavy insulation. Proper venting is required for the sensor to accurately compare process pressure against current atmospheric pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419181931,"sku":"084G2107","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/084g2107-m5g023xbbg0.png?v=1776136982","url":"https:\/\/www.plcprotech.com\/fr\/products\/084g2107-danfoss-emp-2-series-heavy-duty-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}