{"product_id":"130b1107-danfoss-vlt-series-control-panel-lcp-102","title":"130B1107 Panneau de contrôle série Danfoss VLT LCP 102","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e130B1107 (130B1107)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance VLT Control Panel LCP 102 designed specifically for the Danfoss VLT AutomationDrive series. As the primary human-machine interface (HMI), this graphical control unit provides seamless interaction with frequency converters in demanding industrial environments such as wastewater treatment plants, HVAC systems, and chemical processing facilities. By enabling real-time monitoring and rapid parameter adjustments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e130B1107\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimizes system commissioning time and reduces critical downtime. Its robust design ensures reliable data visualization and diagnostics, allowing engineers to maintain optimal motor control and energy efficiency across complex automated architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VLT Control Panel LCP 102 is engineered with a multi-language graphical display that supports a wide array of international character sets. It features a hot-plug capability, allowing operators to attach or remove the panel during drive operation without interrupting the power supply. The unit integrates a built-in copy function, enabling the storage of up to five different sets of parameter data, which simplifies the cloning of settings across multiple drives. The hardware interface includes dedicated navigation keys and a status LED array for immediate fault identification. It is designed to meet IP66 ingress protection ratings when mounted in a remote door kit, ensuring resilience against dust and high-pressure water jets in wash-down areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130B1107\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT AutomationDrive FC 102 \/ 202 \/ 301 \/ 302\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGraphical LCD with Backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark \/ EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP66 (Front side when mounted)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug-and-Play RS-485 Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 130B1107 support the transfer of parameters between different power sizes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the LCP 102 can store parameter sets from one drive and download them to another, provided the drives belong to the same VLT series. However, motor-specific data should be verified after transfer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I troubleshoot a blank display when the drive is powered on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the physical connection between the LCP and the drive cradle. If using a remote mounting kit, verify the cable length does not exceed 3 meters and ensure there is no electromagnetic interference (EMI) affecting the link.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the LCP 102 compatible with the older LCP 101 numerical displays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 130B1107 is the graphical upgrade for the VLT series. While it fits the same physical slot as the LCP 101, it offers enhanced diagnostic graphs and full-text descriptions which are not available on the numerical version.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the 130B1107 in a remote configuration (cabinet door mounting), always use a shielded twisted pair cable for the serial connection. Ensure the shield is grounded at the drive end to prevent signal corruption from high-frequency noise generated by the inverter stages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the panel is rated for 50 deg C, prolonged exposure to direct sunlight or high-intensity UV rays can degrade the LCD contrast over time. In outdoor installations, use a protective weather shield or a tinted transparent cover to extend the service life of the display.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore performing a \"Copy to LCP\" operation for mass commissioning, ensure the drive firmware version is compatible with the LCP 102 software revision. Mismatched versions may result in \"Parameter Error\" notifications during the upload\/download process.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102414266731,"sku":"130B1107","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/130b1107-jiseyzhzbnl.png?v=1776137013","url":"https:\/\/www.plcprotech.com\/fr\/products\/130b1107-danfoss-vlt-series-control-panel-lcp-102","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}