{"product_id":"131b5474-danfoss-vlt-hvac-drive-fc-102-7-5kw-frequency-converter","title":"Convertisseur de fréquence VLT HVAC Drive FC-102 7.5kW Danfoss 131B5474","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131B5474 (131B5474)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premium variable frequency drive from the Danfoss VLT® HVAC Drive FC-102 series, specifically engineered for high-performance motor control in building automation systems. Delivering 7.5 kW (10 HP) of power, this drive is the industry standard for managing sophisticated HVAC infrastructures, including air handling units (AHUs), cooling towers, and centrifugal pumps. Unlike basic micro drives, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131B5474\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures advanced software functions such as the Intelligent Air Handling Unit controller and automated energy optimization (AEO), which significantly reduce the total cost of ownership. Housed in a compact IP20 enclosure, it offers seamless integration into three-phase 380-480 VAC power grids, ensuring maximum uptime and efficiency for critical climate control applications.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model designation\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-102P7K5T4E20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eidentifies the specific technical build and capabilities of the unit:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC\u003c\/strong\u003e: Part of the VLT® flagship Drive family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e102\u003c\/strong\u003e: Indicates the 102 series, a dedicated drive for advanced HVAC and refrigeration applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP7K5\u003c\/strong\u003e: Defines the power rating as 7.5 kW (equivalent to 10 Horsepower).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT4\u003c\/strong\u003e: Three-phase input designed for a mains voltage range of 380 - 480 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: Protection rating of IP20 (Chassis), optimized for installation within protected control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e131B5474\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT® HVAC Drive FC-102\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW \/ 10 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 - 480 VAC (3-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C (with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e98%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat distinguishes the FC-102 from the FC-101 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131B5474\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(FC-102) is a modular, high-end drive that supports a wider range of fieldbus options, more advanced HVAC-specific software features (like \"Stairwell Pressurization Mode\"), and a more robust hardware design capable of managing larger, more complex motor loads compared to the Basic FC-101 series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be integrated into a BACnet or LonWorks network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FC-102 series is designed for open communication. It supports standard HVAC protocols like BACnet (MS\/TP and IP), Modbus RTU, and can be expanded with optional plug-in modules for LonWorks, Profibus, or Profinet depending on the BMS requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Smart Logic Controller\" in the FC-102?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Smart Logic Controller allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131B5474\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto perform simple PLC-like functions. It can be programmed to react to sensor inputs (e.g., temperature or pressure) and execute specific actions without needing an external controller, which is ideal for independent pump or fan control loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Thermal Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an efficiency of 98%, the drive still generates a small amount of heat. Ensure the cabinet ventilation is sized to dissipate the thermal output of a 7.5 kW load. For the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131B5474\u003c\/strong\u003e, maintain at least 100 mm of vertical clearance above and below the chassis for unobstructed airflow through the internal heat sink.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo minimize electromagnetic interference in building electronics, use shielded motor cables. The shield must be connected to the drive's metal decoupling plate using a 360-degree high-frequency clamp. Ensure the drive is grounded to the cabinet's main earth bar with a short, low-impedance conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonic Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn facilities with sensitive medical or data equipment, monitor the total harmonic distortion (THD). The FC-102 includes integrated DC-link chokes as standard, which significantly reduces harmonic interference compared to drives without built-in impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416363883,"sku":"131B5474","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131b5474-h1ltyu5nt0f.png?v=1776137004","url":"https:\/\/www.plcprotech.com\/fr\/products\/131b5474-danfoss-vlt-hvac-drive-fc-102-7-5kw-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}