{"product_id":"131l9864-danfoss-vlt-hvac-basic-drive-fc-101-2-2kw-frequency-converter","title":"131L9864 Variateur de fréquence Danfoss VLT HVAC Basic Drive FC-101 2,2 kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9864 (131L9864)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency VLT® HVAC Basic Drive FC-101 designed by Danfoss to provide precision motor control for 2.2 kW (3.0 HP) applications. Engineered specifically for the HVAC sector, this frequency converter optimizes the performance of pumps, fans, and compressors in commercial and industrial building automation systems. By utilizing advanced variable speed technology, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9864\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces energy consumption and mechanical wear on drive components. Its compact IP20 enclosure is designed for efficient cabinet integration, while the integrated H4 RFI filter ensures electromagnetic compatibility (Class A1\/C2), making it a reliable choice for mission-critical ventilation and climate control infrastructures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P2K2T4E20H4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a modular logic that defines its core operational parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC\u003c\/strong\u003e: Part of the VLT® HVAC Drive family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e101\u003c\/strong\u003e: Specifically the 101 series (HVAC Basic Drive).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP2K2\u003c\/strong\u003e: Represents a power rating of 2.2 kW \/ 3.0 HP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT4\u003c\/strong\u003e: Three-phase input configured for 380 - 480 VAC mains voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: Protection rating of IP20 (Chassis\/Open type), requiring installation in a control panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH4\u003c\/strong\u003e: Integrated RFI filter compliant with Class A1 (Category C2) standards for reduced electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e131L9864\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT® HVAC Basic Drive FC-101\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 kW \/ 3.0 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 - 480 VAC (3-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass A1 (C2) Integrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C (with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;96%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 131L9864 support communication with building management systems (BMS)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FC-101 series comes standard with built-in HVAC protocols including BACnet, Modbus RTU, and FC Protocol. This allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9864\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto seamlessly integrate with central controllers for remote monitoring and automated energy management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external filter required to meet industrial EMC standards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit includes an integrated H4 (Class A1\/C2) RFI filter. For most industrial and commercial installations, no additional filtering is required to meet electromagnetic emission standards, provided that shielded motor cables are installed correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the cooling requirements for this 2.2 kW drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9864\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis air-cooled. For IP20 chassis models, ensure the control cabinet has sufficient airflow to keep the ambient temperature below 40 deg C for full-rated performance. Operation up to 50 deg C is possible with calculated current derating.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Mounting \u0026amp; Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure proper convection through the heat sink, the drive must be mounted vertically. Maintain at least 100 mm of free space above and below the unit. The FC-101 supports side-by-side mounting (\"bookstyle\"), which allows for high-density installation in compact electrical panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Shielding Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo utilize the benefits of the H4 RFI filter, use screened (shielded) motor cables. The shield must be connected to the metal decoupling plate of the drive using a 360-degree clamp to effectively divert high-frequency noise to ground and protect nearby sensitive electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Protection Settings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUpon commissioning, ensure the motor nameplate data (Voltage, Frequency, Current) is accurately entered into the drive's parameter group 1-2. This allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9864\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto provide thermal overload protection and optimize the VVC+ (Voltage Vector Control) for maximum torque efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416626027,"sku":"131L9864","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131l9864-2ogs5ab5cht.png?v=1776137017","url":"https:\/\/www.plcprotech.com\/fr\/products\/131l9864-danfoss-vlt-hvac-basic-drive-fc-101-2-2kw-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}