{"product_id":"3201-triconex-tricon-communication-module","title":"Module de communication Triconex Tricon 3201","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3201 (3201)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-speed bridge between the Triconex safety controller and external plant networks. As a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCommunication Module\u003c\/strong\u003e, it allows the Tricon system to interface seamlessly with Distributed Control Systems (DCS), Human-Machine Interfaces (HMI), and other PLCs without compromising the integrity of the safety loop. In critical environments like offshore drilling or automated chemical refineries, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 3201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that real-time diagnostic data and process variables are transmitted reliably. By offloading communication tasks from the Main Processors, this module protects the safety logic execution speed, ensuring the system can respond to emergency conditions in milliseconds.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Architectural Logic\u003c\/h3\u003e\n\u003cp\u003eBuilt to operate on a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elogic header, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for electrical stability and data consistency. It features a highly sensitive power management circuit capable of handling an input power interruption of up to 1 ms from the nominal value, ensuring that transient voltage dips do not drop the communication link. The module operates within a flexible voltage range of 19.2 to 30 VDC, incorporating advanced filtering to neutralize up to 5% AC ripple. Its internal repetition rate is clocked at a 1-second minimum, providing a deterministic heartbeat for network polling and ensuring that the data presented to the SCADA system is consistently refreshed and synchronized with the TMR core.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3201\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriconex (Schneider Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperational Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.2 VDC to 30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Power Interruption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRipple Tolerance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% AC Ripple\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 cm x 16.9 cm x 4.4 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 kg (Net) \/ 7.5 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEstimated Lead Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 6 Weeks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCritical Technical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 1 ms power interruption limit impact system design?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1 ms threshold indicates the module's high sensitivity to power quality. To ensure stable communication, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be powered by a high-quality, regulated 24 VDC supply. If your facility experiences frequent power \"noise,\" an additional power conditioning filter is recommended to prevent communication time-outs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 3201 support hot-swapping within the Tricon chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, like most Triconex modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for online replacement. When inserted into a redundant slot, the module will automatically initialize and resume data transmission protocols once it passes its internal POST (Power-On Self-Test).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 1-second repetition rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1-second minimum repetition rate defines the interval at which the module processes its primary communication stack. This ensures that the network bus is not overloaded while maintaining a reliable stream of safety-critical data to external monitoring equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent external cyber threats or broadcast storms from impacting the safety rack, always install the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebehind a dedicated industrial firewall or within a secure VLAN.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the 5 kg weight and the sensitivity to AC ripple, ensure the module is fully seated and the chassis thumb-screws are tightened to the specified torque. This ensures a low-impedance path to the ground plane, which is essential for error-free high-speed data transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the module is compact (4.4 cm width), communication processing generates localized heat. Maintain unobstructed airflow through the chassis to ensure the operational temperature does not exceed 60 Celsius, which could lead to intermittent packet loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRobust Performance Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for the \"Always-On\" philosophy of the Triconex brand. Its mechanical design, weighing a substantial 5 kg, reflects a heavy-duty industrial build that protects internal oscillators and RISC processors from the high-frequency vibrations common in turbine control rooms. The module's ability to tolerate a wide DC voltage swing (up to 30 VDC) makes it exceptionally resilient to the charging cycles of large 24 V battery backup banks. This durability, combined with its rigorous diagnostic self-testing, makes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 3201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ea cornerstone for any safety system requiring transparent yet secure data integration.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":53102420885867,"sku":"3201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3201-tra1lpcig14.png?v=1776137098","url":"https:\/\/www.plcprotech.com\/fr\/products\/3201-triconex-tricon-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}