{"product_id":"6gk5992-2am00-8aa0-siemens-scalance-x-media-module-mm992-2ld","title":"6GK5992-2AM00-8AA0 Module média Siemens SCALANCE X MM992-2LD","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6GK5992-2AM00-8AA0 (6GK59922AM008AA0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance SCALANCE X media module designed for long-distance industrial Ethernet communication.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-986 citation-end-986\"\u003eSpecifically identified as the MM992-2LD, this module features two 1000 Mbit\/s SC ports engineered for single-mode optical fiber transmission, supporting distances up to 10 km.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePrimarily utilized in large-scale infrastructure projects such as smart grids, oil and gas pipelines, and expansive automotive manufacturing plants, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6GK5992-2AM00-8AA0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the critical backbone for high-bandwidth data backhaul. Its ruggedized construction ensures reliable operation in EMI-heavy environments, offering superior galvanic isolation and signal stability to prevent network jitter and significantly reduce the risk of industrial communication failures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6GK5992-2AM00-8AA0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eemploys a modular plug-in architecture compatible with the SCALANCE X-300 and XR-500 managed switch families. This module utilizes advanced laser optics for single-mode fiber (SMF) interfaces, providing a high-speed 2-port Gigabit Ethernet uplink. The hot-swappable design allows for network expansion or maintenance without interrupting the power supply to the host switch, which is vital for maintaining 24\/7 uptime in automated facilities. The hardware is designed for extreme durability, featuring a compact form factor that maintains optimal airflow within the switch chassis.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-985 citation-end-985\"\u003eWith a maximum reach of 10 km, it effectively bridges the gap between decentralized control rooms and remote field sites, utilizing the SC-port standard for secure and stable physical connectivity.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6GK5992-2AM00-8AA0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSiemens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSCALANCE X (MM992-2LD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePort Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 1000 Mbit\/s SC-ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFiber Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-mode Optical (SMF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out (Legacy Support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.00 x 10.00 x 2.20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85176200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 6GK5992-2AM00-8AA0 compatible with multi-mode fiber?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module is specifically calibrated for single-mode fiber (9\/125 µm). Using it with multi-mode fiber will result in high signal attenuation and will not achieve the rated 10 km distance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"Phase-Out\" status for my facility?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Phase-Out\" status indicates that while Siemens is transitioning to newer generations, this module is still fully supported for maintenance and spare parts. It is essential for facilities standardizing on SCALANCE X-300\/500 hardware to keep original stock to avoid costly network re-designs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I hot-swap this module while the switch is operational?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MM992-2LD supports hot-swapping. However, always ensure the fiber optic cables are disconnected before removing the module to prevent laser exposure and protect the optical interfaces from dust contamination.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Path Budget:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen planning a 10 km run, ensure the total optical loss (including splices and patch panels) does not exceed the module's power budget. Use a calibrated optical power meter during commissioning to verify that the received signal strength falls within the specified operational window to prevent bit errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDust Management:\u003c\/strong\u003e\u003cspan class=\"citation-984 citation-end-984\"\u003e\u003cspan\u003e \u003c\/span\u003eFiber optic SC-ports are highly sensitive to microscopic contamination.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAlways keep the protective dust caps on the module and the fiber connectors until the moment of insertion. Even a single speck of dust can cause a permanent \"burn-in\" on the laser interface at Gigabit speeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen routing single-mode fiber from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6GK5992-2AM00-8AA0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough cabinet conduits, maintain a minimum bend radius of at least 30 mm (or as specified by the cable manufacturer).\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-983 citation-end-983\"\u003eTight bends cause \"macro-bending\" loss, which can lead to intermittent link drops or reduced throughput.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLaser Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module is a Class 1 Laser Product. While safe under normal operation, never look directly into the optical ports or the end of a connected fiber cable while the module is powered, as infrared laser light is invisible to the human eye but can cause retinal damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716787663211,"sku":"6GK5992-2AM00-8AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5992-2am00-8aa0-xbec0h2tgb5_2e8acf0a-a98e-4256-bdcd-68b59d814b74.jpg?v=1767089809","url":"https:\/\/www.plcprotech.com\/fr\/products\/6gk5992-2am00-8aa0-siemens-scalance-x-media-module-mm992-2ld","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}