{"product_id":"6sl3330-6tg38-8aa3","title":"Siemens 6SL3330-6TG38-8AA3 Module Smart Line SINAMICS S120","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6SL3330-6TG38-8AA3\u003c\/strong\u003e is a chassis-format Smart Line Module within the SINAMICS S120 drive system. This unregulated rectifier\/regenerative unit supplies power to a common DC link, allowing connected motor modules to draw electrical energy. It features regenerative feedback capabilities, enabling it to return braking kinetic energy back into the three-phase supply network to optimize overall plant energy efficiency. Communication and control integration within the SINAMICS ecosystem are handled through integrated Drive-CLiQ digital interfaces.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInfeed and regenerative feedback capabilities to the supply network\u003c\/li\u003e\n\u003cli\u003eCommon DC link supply for multi-axis configurations\u003c\/li\u003e\n\u003cli\u003eDrive-CLiQ communication interfaces for auto-configuration and diagnostics\u003c\/li\u003e\n\u003cli\u003eIntegrated fan for internal forced-air cooling\u003c\/li\u003e\n\u003cli\u003eOpen chassis design optimized for control cabinet integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis drive configurations in metal production and rolling mills\u003c\/li\u003e\n\u003cli\u003eHigh-power test stands and dynamometers\u003c\/li\u003e\n\u003cli\u003eMain drives for paper, textile, and printing machines\u003c\/li\u003e\n\u003cli\u003eHoists, cranes, and materials handling systems with high braking energy requirements\u003c\/li\u003e\n\u003cli\u003eLarge-scale industrial pumps, fans, and compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectrical ParametersValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eLine Voltage\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e3-phase AC 500 V to 690 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eDC Link Voltage\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eDC 675 V to 930 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eRated Power\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e710 kW (at 690 V) \/ 790 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eRated Input Current\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e900 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eRated Output Current (DC)\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1070 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eDC Link Capacitance\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e22400 microfarads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eMechanical and EnvironmentalValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eFrame Size\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eHX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eInternal forced air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eRequired Cooling Airflow\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.36 cubic meters per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSound Pressure Level\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e71 dB (at 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eWidth\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e704 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eHeight\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e1475 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eDepth\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e548 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e290 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eConnections \/ Interfaces\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eInterface \/ TerminalFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eU1, V1, W1\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eThree-phase AC line supply input terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eDCP, DCN\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eDC link busbar connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eX400\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDigital inputs\/outputs and control supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eX500 (Drive-CLiQ)\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eSystem communication interface to Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003ePE\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eProtective Earth grounding stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is mounted vertically inside a suitable IP20 or higher enclosure to comply with safety standards, as the bare chassis is rated IP00.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum clearance distances at the top and bottom of the unit as specified in the manual to facilitate proper airflow and prevent thermal derating.\u003c\/li\u003e\n\u003cli\u003eConnect a low-impedance Protective Earth (PE) conductor directly to the chassis ground stud to mitigate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eRoute power cables (AC input and DC link) separately from low-voltage control and Drive-CLiQ communication lines.\u003c\/li\u003e\n\u003cli\u003eInstall external line reactors and semiconductor fuses rated specifically for this module to protect against overcurrent and line disturbances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of a Smart Line Module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt rectifies the incoming three-phase AC line voltage into a stable DC link voltage while allowing excess braking energy to feed back into the power grid.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module include a built-in control unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it operates as a power component and requires a separate SINAMICS Control Unit, such as a CU320-2, via a Drive-CLiQ connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the ingress protection rating of this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module has an IP00 rating and must be installed within a protective electrical cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit handle internal heat dissipation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt utilizes an integrated forced-air cooling fan that requires a continuous, unobstructed airflow through the chassis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat AC supply voltage range can this module accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt accepts a three-phase AC line input between 500 V and 690 V at a frequency of 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support regulated DC link voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the DC link voltage is unregulated and varies proportionally with the incoming AC line voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat size framework does this module belong to?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module utilizes the Siemens frame size HX chassis configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be used in multi-axis setups?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is specifically designed to supply a common DC link that feeds multiple independent Motor Modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat interface is used for communication with the main controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system uses the proprietary Siemens Drive-CLiQ digital interface protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external line reactor required for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, a matching line reactor is necessary to ensure correct commutation and line-harmonics reduction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the unit be mounted horizontally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it must be mounted vertically to allow the forced air cooling system to operate efficiently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the internal fan fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive system will detect a thermal fault via internal sensors and safely trip to protect the power electronics from overheating.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715770184043,"sku":"6SL3330-6TG38-8AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6sl3330-6tg38-8aa3-3terxjvyj0c_dc9c9c2a-2964-4e05-9777-5433f632583b.jpg?v=1767070756","url":"https:\/\/www.plcprotech.com\/fr\/products\/6sl3330-6tg38-8aa3","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}