{"product_id":"900h02-0102-honeywell-controledge-hc900-digital-output-module","title":"900H02-0102 Module de sortie numérique Honeywell ControlEdge HC900","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e900H02-0102 (900H02-0102)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell ControlEdge HC900 Digital Output Module delivers 16-channel low side switching control for industrial automation systems. It operates with externally powered field loads and supports two isolated groups of eight outputs. Each group provides independent power terminals for stable distribution and fault separation. The module integrates intelligent power switching with built in electronic protection per channel. It serves continuous process industries such as oil refining, power generation, and chemical processing plants. Engineers deploy it to maintain reliable actuator control and reduce unplanned downtime in critical loops. Each channel includes LED status indication for real time diagnostics and fault visibility. The module supports fast response switching for high speed control applications. It also maintains stable operation under electrical stress and thermal variation. The design improves system uptime through automatic overload limitation and diagnostic reporting. It fits seamlessly into Honeywell HC900 ControlEdge architectures for scalable distributed control.\u003c\/p\u003e\n\u003ch3\u003eCore Architecture and Electrical Design\u003c\/h3\u003e\n\u003cp\u003eThe module uses two isolated output banks to reduce fault propagation risk. Each bank supports eight current sinking outputs with shared field supply terminals. Intelligent power switches manage overload and temperature protection per channel. Internal diagnostics continuously monitor module health and output behavior. LED indicators provide direct visualization of channel activity and system status. The design ensures compatibility with standard DC industrial loads and actuators. It supports inductive and resistive loads within defined electrical limits. Backplane communication integrates with HC900 controller scan cycles for synchronized control execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900H02-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (2 x 8 isolated groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking, low side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e6.5 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Voltage\u003c\/td\u003e\n\u003ctd\u003e34 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.3 VDC at 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e1 A per point, 8 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.15 mA at 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e6 ms ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 340 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 900H02-0102 compatible with all HC900 controllers?\u003c\/strong\u003e\u003cbr\u003eIt is fully compatible with Honeywell ControlEdge HC900 system architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during output overload conditions?\u003c\/strong\u003e\u003cbr\u003eEach channel shuts down electronically and requires power cycle reset.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it drive inductive loads like solenoids?\u003c\/strong\u003e\u003cbr\u003eYes, within specified current and inductance limits up to 5 mH.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support redundancy?\u003c\/strong\u003e\u003cbr\u003eIt supports isolated groups but not full module redundancy by itself.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e900H02-0102 (900H02-0102)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell ControlEdge HC900 Digital Output Module delivers 16-channel low side switching control for industrial automation systems. It operates with externally powered field loads and supports two isolated groups of eight outputs. Each group provides independent power terminals for stable distribution and fault separation. The module integrates intelligent power switching with built in electronic protection per channel. It serves continuous process industries such as oil refining, power generation, and chemical processing plants. Engineers deploy it to maintain reliable actuator control and reduce unplanned downtime in critical loops. Each channel includes LED status indication for real time diagnostics and fault visibility. The module supports fast response switching for high speed control applications. It also maintains stable operation under electrical stress and thermal variation. The design improves system uptime through automatic overload limitation and diagnostic reporting. It fits seamlessly into Honeywell HC900 ControlEdge architectures for scalable distributed control.\u003c\/p\u003e\n\u003ch3\u003eCore Architecture and Electrical Design\u003c\/h3\u003e\n\u003cp\u003eThe module uses two isolated output banks to reduce fault propagation risk. Each bank supports eight current sinking outputs with shared field supply terminals. Intelligent power switches manage overload and temperature protection per channel. Internal diagnostics continuously monitor module health and output behavior. LED indicators provide direct visualization of channel activity and system status. The design ensures compatibility with standard DC industrial loads and actuators. It supports inductive and resistive loads within defined electrical limits. Backplane communication integrates with HC900 controller scan cycles for synchronized control execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900H02-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (2 x 8 isolated groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent sinking, low side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e6.5 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Voltage\u003c\/td\u003e\n\u003ctd\u003e34 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.3 VDC at 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e1 A per point, 8 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.15 mA at 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e6 ms ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 340 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 900H02-0102 compatible with all HC900 controllers?\u003c\/strong\u003e\u003cbr\u003eIt is fully compatible with Honeywell ControlEdge HC900 system architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during output overload conditions?\u003c\/strong\u003e\u003cbr\u003eEach channel shuts down electronically and requires power cycle reset.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it drive inductive loads like solenoids?\u003c\/strong\u003e\u003cbr\u003eYes, within specified current and inductance limits up to 5 mH.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support redundancy?\u003c\/strong\u003e\u003cbr\u003eIt supports isolated groups but not full module redundancy by itself.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a grounded control cabinet to reduce electrical noise. Maintain proper separation between field wiring and signal wiring. Use shielded cables for inductive load circuits in high interference environments. Ensure torque tightening follows Honeywell cabinet wiring standards. Verify external power supply stability before commissioning. Avoid exceeding 8 A total module load to prevent thermal stress. In high vibration environments, secure terminal blocks with periodic inspection. Maintain airflow around racks to control internal temperature rise.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705777746283,"sku":"900H02-0102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900H02-0102-am2udww5qrx_1ee7cfb6-a929-4b4d-9e27-c6ab65a3a84c.jpg?v=1766659687","url":"https:\/\/www.plcprotech.com\/fr\/products\/900h02-0102-honeywell-controledge-hc900-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}