{"product_id":"abb-acs580-01-12a7-4-acs580-ac-drive","title":"ABB ACS 580 ACS580-01-12A7-4 Servomoteurs","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to simplify motor control across various industrial processes, the \u003cstrong\u003eACS580-01-12A7-4\u003c\/strong\u003e wall-mounted variable frequency drive delivers effortless energy efficiency and precise control for standard applications. This all-compatible drive module is pre-configured to control pumps, fans, conveyors, mixers, and other variable torque loads without complex setup procedures. Built on a robust platform, the drive features integrated essential components such as an EMC filter, a choke for harmonic mitigation, and a Modbus RTU fieldbus interface, minimizing the footprint and cabinet space required for installation.\u003c\/p\u003e\n\n\u003cp\u003eOperating with a nominal current of 12.7 A on a 3-phase supply voltage ranging from 380 to 480 V, the \u003cstrong\u003eACS580-01-12A7-4\u003c\/strong\u003e optimizes motor performance via both scalar and vector control modes. It incorporates an intuitive control panel with assistant functionality, allowing engineers to perform rapid commissioning, diagnostic monitoring, and real-time maintenance checks. The drive's built-in energy optimizer and calculators monitor consumption, enabling facilities to track and reduce operational carbon footprints.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAll-Compatible Architecture:\u003c\/strong\u003e Pre-integrated components reduce installation complexity, engineering time, and external hardware requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Motor Control:\u003c\/strong\u003e Supports both scalar control for straightforward pump\/fan applications and vector control for superior dynamic performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHarmonic Reduction:\u003c\/strong\u003e Built-in variable swing choke mitigates harmonics at both full and partial loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmbedded Functional Safety:\u003c\/strong\u003e Integrated Safe Torque Off (STO) SIL 3 \/ PL e terminal ensures safe maintenance access and system compliance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Connectivity:\u003c\/strong\u003e Standard embedded Modbus RTU interface with optional fieldbus adapter modules for seamless network integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCentrifugal pumps and fluid handling systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial ventilation, supply, and extract fans\u003c\/li\u003e\n  \u003cli\u003eMaterial handling conveyors and automated sorting lanes\u003c\/li\u003e\n  \u003cli\u003eCompressors, mixers, and general-purpose agitators\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eACS580-01-12A7-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDrive Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eACS580\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP21 (UL Type 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eR1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage (U1)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3-phase 380 to 480 V AC (+10% \/ -15%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Current (I2)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.7 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypical Motor Power (Light-Overload)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.5 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypical Motor Power (Heavy-Duty)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 \/ 60 Hz (+\/- 5%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-15 to +50 degC (derating applies above 40 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.60 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Group\u003c\/th\u003e\n      \u003cth\u003eDefault Connection Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSCR\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSignal cable shield termination\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAI1 \/ AI2\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog inputs (Speed reference \/ feedback)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAO1 \/ AO2\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog outputs (Motor speed \/ current monitoring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDI1 - DI6\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDigital inputs (Start, stop, direction, interlocks)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRO1 \/ RO2 \/ RO3\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRelay outputs (Ready, running, faulted indications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSTO\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSafe Torque Off dual-channel safety circuit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEIA-485\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEmbedded Modbus RTU communication link\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Location:\u003c\/strong\u003e Install vertically on a flat, non-flammable surface. Ensure the wall is capable of supporting the drive weight of 4.60 kg.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Clearances:\u003c\/strong\u003e Maintain a minimum free space of 75 mm above and 75 mm below the drive module to allow proper airflow and prevent thermal derating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling Requirements:\u003c\/strong\u003e Use symmetrical shielded motor cables (EMC-compliant) to minimize high-frequency electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the drive protective earth (PE) terminal to the central ground busbar using short, low-impedance cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL, cUL\u003c\/li\u003e\n  \u003cli\u003eEAC\u003c\/li\u003e\n  \u003cli\u003eRCM\u003c\/li\u003e\n  \u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701957325163,"sku":"ACS580-01-12A7-4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/acs580-01-12a7-4-4cvz043gkge_5ea15705-142a-4c7f-9a98-600c4946a2be.jpg?v=1766478118","url":"https:\/\/www.plcprotech.com\/fr\/products\/abb-acs580-01-12a7-4-acs580-ac-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}