{"product_id":"abb-acs880-01-124a-5-acs880-variable-frequency-drive","title":"Variateur de fréquence ABB ACS880-01-124A-5 ACS880","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding heavy-duty motor control capabilities in demanding industrial environments, the \u003cstrong\u003eABB ACS880-01-124A-5\u003c\/strong\u003e wall-mounted variable frequency drive delivers robust speed and torque regulation for continuous processes. Engineered to operate on a \u003cstrong\u003e3-phase 500 V supply\u003c\/strong\u003e, this highly reliable inverter module features a nominal rating of \u003cstrong\u003e75 kW\u003c\/strong\u003e and a current capacity of \u003cstrong\u003e124 A\u003c\/strong\u003e. Built with a rugged \u003cstrong\u003eIP21 protective enclosure\u003c\/strong\u003e, it utilizes ABB proprietary Direct Torque Control (DTC) technology to ensure outstanding motor performance and energy efficiency across variable load profiles.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Torque Control (DTC):\u003c\/strong\u003e Delivers premium open-loop and closed-loop motor torque accuracy and dynamic response times.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Harmonics Mitigation:\u003c\/strong\u003e Built-in AC choke reduces harmonic distortion to protect utility networks and auxiliary devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety Integrated:\u003c\/strong\u003e Safe Torque Off (STO) hardware loop enables safe machine intervention and SIL 3 \/ PL e safety ratings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRemovable Control Unit:\u003c\/strong\u003e Designed with front-accessible, robust terminals for simplified parameter backups, commissioning, and commissioning tasks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Cooling Layout:\u003c\/strong\u003e Cooled via an integrated speed-controlled fan to maximize lifetime performance and reduce internal thermal stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and Wastewater:\u003c\/strong\u003e Large centrifugal water pumps, high-volume aeration blowers, and municipal booster systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Continuous heavy-duty conveyor belts, industrial winches, and overhead cranes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Industries:\u003c\/strong\u003e High-torque extruders, mixers, agitators, and rotary kilns.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC and Infrastructure:\u003c\/strong\u003e Centrifugal air handlers, heavy industrial chillers, and smoke extraction fans.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; min-width: 500px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Identifier\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eACS880-01-124A-5\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eACS880 Series Single Drives\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Power (Heavy-Duty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e75 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNominal Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e124 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNominal Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e380 to 500 V AC (3-Phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEnclosure Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP21 (UL Type 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFrame Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eR5\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature Limit\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-15 to +50 degC (derating above 40 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e35.00 kg (77.16 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e727 mm x 357 mm x 252 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; min-width: 500px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold; color: #1a365d;\"\u003eTerminal block \/ Connector\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eU1, V1, W1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-Phase AC power supply input terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eU2, V2, W2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-Phase motor output terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eUDC+, UDC-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDC bus connections for external braking units or common DC bus configurations\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eXAI \/ XAO\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAnalog input and analog output signals (speed, current, torque references)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eXDI \/ XDIO\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDigital input and digital input\/output configurations for interlocking and control sequences\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eXOUT \/ STO\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSafe Torque Off dual-channel safety system terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe ACS880-01-124A-5 utilizes the standard \u003cstrong\u003eR5 frame size\u003c\/strong\u003e footprint, making it physically retrofittable in enclosures designed for older ACS550 or ACS800 series configurations of similar power ratings, though careful checking of ventilation clearances is required. Ensure firmware profiles on your ZCON or ZCU control board match auxiliary fieldbus option cards (e.g., FENA-21 for Profinet or FPBA-01 for Profibus DP) to avoid module configuration errors upon power-up.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing this drive with high-inertia loads such as large industrial fans or centrifuges, avoid fast deceleration ramps without checking the thermal capacity of the internal DC bus. Rapidly decelerating massive loads generates regenerative electrical energy that can cause \u003cstrong\u003eDC Overvoltage Faults (Fault Code 3210)\u003c\/strong\u003e. In such configurations, integrating an external dynamic brake chopper and resistor bank is highly recommended.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo protect motor insulation and bearings from common-mode voltage damage, utilize symmetrical shielded motor cables. Ensure the cable shield is grounded 360 degrees both inside the drive housing and at the motor junction box. Never run signal control wiring alongside high-voltage motor or mains cables; maintain at least 200 mm of physical separation or use perpendicular crossings to minimize induced electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eElectrical installation must only be performed by qualified automation technicians. Completely de-energize and lock out all AC input power circuits before opening the enclosure. Wait at least 5 minutes after isolation to allow the high-voltage DC bus capacitors to fully discharge. Always confirm the absence of residual voltage with a calibrated digital multimeter before contacting terminals.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Mount the R5 frame vertically onto a non-flammable solid surface. Ensure minimum clearances of 150 mm above and below the cooling intake\/exhaust regions are strictly maintained.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003ePower \u0026amp; Grounding Connections:\u003c\/strong\u003e Connect the incoming 3-phase mains to terminals U1, V1, and W1. Connect the shielded motor cable directly to terminals U2, V2, and W2. Securely clamp the PE grounds to the drive frame ground rail.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eControl and Safety I\/O:\u003c\/strong\u003e Strip and wire the remote start\/stop, speed reference, and safety hardware loops. Ensure the dual-channel Safe Torque Off (STO) circuit is bridged or wired to your safety controller.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003ePower-up Sequence:\u003c\/strong\u003e Re-install all drive covers, re-apply primary feed power, and utilize the ABB Assistant Control Panel to execute the Motor ID Run commissioning wizard.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956931947,"sku":"ACS880-01-124A-5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/acs880-01-124a-5-syhm52vfvfp_b14aea0c-0cdf-4df6-a9ad-428e2d7718a3.jpg?v=1766478105","url":"https:\/\/www.plcprotech.com\/fr\/products\/abb-acs880-01-124a-5-acs880-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}