{"product_id":"abb-csk-20-n1-fpr3331001r1202-ac-31-binary-input-output-module","title":"Module d'entrée\/sortie binaire ABB CSK 20 N1 FPR3331001R1202 AC 31","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSK 20 N1 (CSK20N1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a ruggedized Binary Input\/Output expansion unit belonging to the ABB Advant Controller 31 (AC 31) family, specifically designed for use with the ICMK-CS31 remote unit. Identified by product code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFPR3331001R1202 (FPR 333 1001 R1202)\u003c\/strong\u003e, this module facilitates the high-speed exchange of digital signals across the CS31 fieldbus. With 12 dedicated 24 V DC input channels and 8 transistor output channels, it provides the granular control necessary for decentralized automation tasks in water treatment, HVAC systems, and factory assembly lines. By offloading I\/O processing to remote locations, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFPR3331001R1202\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimizes wiring costs and enhances system modularity, proving indispensable for reducing installation time and ensuring the long-term reliability of distributed control architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Voltage Configuration\u003c\/h3\u003e\n\u003cp\u003eThe CSK 20 N1 series is available in three distinct power and voltage variants to accommodate global industrial standards:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFPR3331001R1202\u003c\/strong\u003e: The standard 24 V DC model, utilized for low-voltage control circuits and safety-extra-low-voltage (SELV) applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFPR3331001R0206\u003c\/strong\u003e: The 230 V AC variant, suitable for European and international high-voltage control networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFPR3331001R0204\u003c\/strong\u003e: The 120 V AC variant, engineered primarily for North American industrial power standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Interface\u003c\/strong\u003e: Features 12 Binary Inputs (24 V DC) and 8 Transistor Outputs (24 V DC, 0.5 A) across all variants for signal logic, though supply power differs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSK 20 N1 (FPR3331001R1202)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Family\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdvant Controller 31 (AC 31)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eICMK-CS31 Remote Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBinary Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Channels (24 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBinary Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Transistor Channels (24 V DC, 0.5 A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-isolated (Common Ground per group)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (35 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CSK 20 N1 communicate with the central PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module does not communicate directly with the PLC; it connects to an ICMK-CS31 remote unit, which acts as the bus coupler. The ICMK unit then transmits the I\/O data over the CS31 twisted-pair fieldbus to the Advant Controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I do if the output \"Error\" LED is lit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA lit Error LED on the output side typically indicates a short circuit or an overload (current \u0026gt; 0.5 A) on one of the 8 transistor channels. Power down the unit, verify field wiring for faults, and ensure the total load does not exceed the rated capacity before restarting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC versions on the same ICMK-CS31 remote unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the CS31 bus supports a mix of different remote expansion modules. However, ensure that the power supply wiring to each specific CSK 20 N1 module matches its order code (R1202 for DC, R0206\/R0204 for AC) to avoid terminal damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFieldbus Addressing and Termination\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen adding the CSK 20 N1 to a remote station, ensure the address switches on the associated ICMK-CS31 are set correctly according to your project's I\/O map. For the CS31 bus cable, always use shielded twisted-pair wire. If the remote unit is the last device on the segment, a 120 Ohm termination resistor must be installed across the bus terminals to prevent signal reflections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransistor Output Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 0.5 A transistor outputs are robust, they are susceptible to damage from high-voltage flyback when switching inductive loads (e.g., relay coils). Always install a freewheeling diode (for DC) or an RC snubber (for AC versions) directly at the load. This practice prevents electromagnetic noise from feeding back into the AC 31 bus and extends the operational life of the module's transistors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CSK 20 N1 is designed for natural convection cooling. When mounting multiple units on a DIN rail, maintain a minimum horizontal gap of 10 mm and a vertical clearance of 50 mm between wire ducts. In environments exceeding 45 Celsius, consider forced-air cooling within the cabinet to prevent localized overheating of the transistor output stage.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701959815531,"sku":"FPR3331001R1202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fpr3331001r1202-lftwrzuawdd_c01625f1-636d-4d33-b780-172c7ff53c0a.jpg?v=1766478196","url":"https:\/\/www.plcprotech.com\/fr\/products\/abb-csk-20-n1-fpr3331001r1202-ac-31-binary-input-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}