{"product_id":"abb-ei-813f-3bdh000017r1-ac-800f-ethernet-module","title":"Module Ethernet 10BaseT ABB 3BDH000017R1 EI 813F","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eInterfacing the AC 800F controller with Ethernet networks requires dedicated communication interfaces such as the \u003cstrong\u003eABB EI 813F\u003c\/strong\u003e. This communication module, designated under part number \u003cstrong\u003e3BDH000017R1\u003c\/strong\u003e, provides a reliable 10BaseT twisted-pair connection interface. It serves as a vital component for integrating field controllers into broader industrial plant networks, facilitating stable data transfer to supervisory systems, engineering tools, and adjacent controllers within the AC 800F system architecture.\u003c\/p\u003e\n\n\u003cp\u003eBuilt for industrial environments, the module easily slots into compatible AC 800F backplanes, supporting standard network configurations without the need for complex, proprietary interfaces. Its design ensures minimal latency and high network integrity, matching the rigorous demands of modern distributed control systems (DCS).\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides a dedicated 10BaseT (twisted-pair) Ethernet port.\u003c\/li\u003e\n  \u003cli\u003eFully compatible with the modular ABB AC 800F control system.\u003c\/li\u003e\n  \u003cli\u003eEnsures robust physical and electrical coupling to the system bus.\u003c\/li\u003e\n  \u003cli\u003eSimplifies plant network topology utilizing standard RJ45 cabling connections.\u003c\/li\u003e\n  \u003cli\u003eFacilitates direct engineering and operational access to the field controller level.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed Control Systems (DCS) networking within power generation utilities.\u003c\/li\u003e\n  \u003cli\u003eProcess communication networks in oil and gas, chemical, and refining facilities.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment plant automation system backbones.\u003c\/li\u003e\n  \u003cli\u003eFactory automation systems utilizing the AC 800F hardware platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEI 813F\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3BDH000017R1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAC 800F\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNetwork Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 Mbps (10BaseT)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMedia Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTwisted Pair (STP\/UTP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMalta (MT) \/ Germany (DE)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation of the \u003cstrong\u003eABB EI 813F\u003c\/strong\u003e Ethernet module is critical to maintaining communication integrity:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the host controller rack is powered down or follow official ABB hot-swap protocol guidelines before inserting the module into its designated slot.\u003c\/li\u003e\n  \u003cli\u003eSecure all module mounting screws to ground the unit chassis to the system rack correctly.\u003c\/li\u003e\n  \u003cli\u003eUse Category 5 (Cat5) or higher shielded twisted-pair (STP) cabling to protect communications from industrial electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003eMaintain separation between communication network cables and high-voltage power lines within cable trays and control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955621227,"sku":"3BDH000017R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bdh000017r1-yi2ri5mnu0k_49c344a9-835e-4292-aacd-f2e2d0b6903a.jpg?v=1766478064","url":"https:\/\/www.plcprotech.com\/fr\/products\/abb-ei-813f-3bdh000017r1-ac-800f-ethernet-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}