{"product_id":"abb-s200-ib16-digital-input-module-for-s200-i-o-systems","title":"Module d'entrée numérique ABB S200-IB16 pour systèmes S200 I\/O","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eS200-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital input module from the ABB S200 I\/O series designed for processing 16 discrete 24 VDC field input signals in industrial automation systems. The module uses galvanically isolated optocoupler inputs combined with integrated digital filtering to improve signal stability in electrically noisy environments.\u003c\/p\u003e\n\u003cp\u003eEach input channel includes front-panel LED indication for fast field diagnostics and maintenance verification. The module supports programmable sample time configuration, allowing engineers to optimize input response according to process requirements.\u003c\/p\u003e\n\u003cp\u003eS200-IB16 modules are commonly installed in factory automation systems, process control cabinets, water treatment facilities, and power plant control systems where reliable digital signal acquisition is required for PLC and distributed I\/O applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe S200-IB16 module uses isolated digital input architecture to protect internal logic circuits from field-side electrical disturbances.\u003c\/p\u003e\n\u003cp\u003eKey operating characteristics include:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003eOptocoupler galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Filtering\u003c\/td\u003e\n\u003ctd\u003eIntegrated digital filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eIndividual yellow LED per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eCommon ground shared by 16 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eTerminal base unit connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Function\u003c\/td\u003e\n\u003ctd\u003eProgrammable sample time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe filtering structure uses separate common filter constants for grouped input channels to improve noise immunity during industrial operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS200-IB16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS200 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDigital 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated via optocouplers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Indication\u003c\/td\u003e\n\u003ctd\u003eYellow LED per input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Type\u003c\/td\u003e\n\u003ctd\u003eDigital input filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Time\u003c\/td\u003e\n\u003ctd\u003eProgrammable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eTerminal base mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial PLC and distributed I\/O systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the optocoupler isolation in S200-IB16?\u003c\/strong\u003e\u003cbr\u003eThe optocouplers isolate field input signals from the module logic circuits, reducing the risk of electrical interference and ground loop disturbances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the LED status differ from the PLC input status?\u003c\/strong\u003e\u003cbr\u003ePossible causes include forced inputs, unstable voltage within the transition region, or module failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module operate in high-noise industrial environments?\u003c\/strong\u003e\u003cbr\u003eYes. The integrated digital filtering and galvanic isolation improve signal stability in electrically noisy installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be checked if no LED is active with 24 VDC present?\u003c\/strong\u003e\u003cbr\u003eInspect the terminal base unit and field wiring first. If the issue remains, replace the module and terminal base unit.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eSeparate digital and analog I\/O power wiring using dedicated power-line filters. Mixed routing can introduce electrical interference into analog signal circuits.\u003c\/p\u003e\n\u003cp\u003eDo not install the module close to high-frequency transmitters, variable frequency drives, or radio communication equipment. Industrial electromagnetic interference may affect signal integrity.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cabinet ventilation and avoid installation areas exposed to condensation, oil mist, conductive dust, vibration, or direct sunlight. Long-term environmental stress can shorten I\/O module lifespan.\u003c\/p\u003e\n\u003cp\u003eWhen chaining multiple 24 VDC I\/O modules, verify that the combined current does not exceed terminal block or cable current ratings.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701959586155,"sku":"S200-IB16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/s200-ib16-nhjup2wsm1i_08ec1384-7a6b-4943-8cda-182eaeb3e404.jpg?v=1766478186","url":"https:\/\/www.plcprotech.com\/fr\/products\/abb-s200-ib16-digital-input-module-for-s200-i-o-systems","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}