{"product_id":"abb-tu831v1-3bse013235r1-s800-i-o-extended-mtu-module-termination-unit","title":"ABB TU831V1 3BSE013235R1 Unité de terminaison de module MTU étendu S800 I\/O","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTU831V1\u003c\/strong\u003e is an \u003cstrong\u003eExtended Module Termination Unit (MTU)\u003c\/strong\u003e engineered for the \u003cstrong\u003eABB S800 I\/O\u003c\/strong\u003e system. It provides a reliable mechanical and electrical platform for interfacing field wiring with specified S800 I\/O modules. Featuring a \u003cstrong\u003e2x8 signal terminal\u003c\/strong\u003e configuration, this extended unit breaks out field signals efficiently while establishing the necessary connections to the internal ModuleBus.\u003c\/p\u003e\n\u003cp\u003eIn contrast to low-voltage termination bases, this unit features an insulation rating up to \u003cstrong\u003e250V\u003c\/strong\u003e, making it suitable for standard process voltage networks, high-voltage discrete control loops, and specialized power signaling environments. It integrates smoothly into various generations of decentralized control networks, ensuring consistent signal path distribution without compromising field isolation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtended layout featuring 2x8 signal terminal connections\u003c\/li\u003e\n\u003cli\u003eHigher dielectric rating optimized for applications up to 250V\u003c\/li\u003e\n\u003cli\u003eDirect pass-through connectivity to the S800 ModuleBus interface\u003c\/li\u003e\n\u003cli\u003eCompact footprint optimizing available cabinet real estate\u003c\/li\u003e\n\u003cli\u003eReliable wire-clamp termination points for direct field landing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) managed by ABB System 800xA platforms\u003c\/li\u003e\n\u003cli\u003eLegacy Advant OCS with Master or MOD 300 software via Advant Fieldbus 100\u003c\/li\u003e\n\u003cli\u003eProcess loop terminations in high-density Compact Product Suite infrastructure\u003c\/li\u003e\n\u003cli\u003e120V\/240V AC or DC discrete control interfaces within power generation and water treatment facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\/Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU831V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013235R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule_Termination_Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x8 signal terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSCIP Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo SVHC present Bulgaria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Allocation\u003c\/strong\u003e: Affix the base securely to the designated section of the DIN rail, ensuring standard locking clips engage fully to prevent lateral sliding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Separation\u003c\/strong\u003e: Maintain proper clearance between high-voltage field wiring (up to 250V) routed to this unit and nearby low-voltage instrument signals to minimize electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e: Secure field conductors into the screw clamp or compression terminals using the manufacturer-specified torque limits to avoid loosening from vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Align the mating plug of the matching S800 I\/O module vertically with the guide pins of the MTU before exerting downward force to sit the module securely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the designation \"Extended MTU\" indicate for this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates the presence of an expanded physical layout or additional terminal capacity, structured here as a 2x8 matrix, providing extra termination flexibility for specific I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this termination unit safe for standard 230V AC applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the technical data sheet specifies a maximum insulation threshold of 250V, which accommodates standard 120V and 230V industrial control voltages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this base unit be utilized within an Advant OCS architecture?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is officially classified for use with Advant OCS with Master or MOD 300 software utilizing Advant Fieldbus 100 setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this component contain any substance of very high concern (SVHC)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, according to the official SCIP filing, there are no SVHC present in this hardware variant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the physical weight of the unit without an I\/O module attached?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe net engineering weight of the bare module termination unit is exactly 0.22 kg.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958078827,"sku":"3BSE013235R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013235r1-n2swcuhstsy_0e6457d9-fda2-4fb1-a534-4c9c80718bf4.jpg?v=1766478142","url":"https:\/\/www.plcprotech.com\/fr\/products\/abb-tu831v1-3bse013235r1-s800-i-o-extended-mtu-module-termination-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}