{"product_id":"acs880-01-025a-3-abb-3aua0000107992-industrial-single-drive","title":"Variateur industriel unique ABB ACS880-01-025A-3 3AUA0000107992","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACS880-01-025A-3 (3AUA0000107992)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust, wall-mounted LV AC industrial single drive engineered by ABB to provide high-performance motor control across diverse sectors. Rated at 11 kW and 25 A for 400 V 3-phase systems, this drive is built on ABB's all-compatible drive architecture, ensuring seamless integration into applications ranging from oil and gas to food and beverage. Whether managing heavy-duty extruders and winches or optimizing centrifugal pumps and fans, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACS880-01-025A-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers precise torque and speed control.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-74 citation-end-74\"\u003eIts compact R2 frame size allows for easy wall-mounting or cabinet installation, while the standard built-in choke effectively manages harmonic filtering to protect your facility's power quality.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACS880-01-025A-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed with industrial versatility and safety as core priorities:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Profiles:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Normal Use (11 kW\/25 A), Light-Overload (11 kW\/24 A), and Heavy-Duty (7.5 kW\/17 A) ratings to match the specific torque requirements of different machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Harmonics Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a built-in choke as standard to reduce total harmonic distortion (THD), eliminating the need for bulky external line reactors in many setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a wide array of interfaces including 2 Analog Inputs, 2 Analog Outputs, and 6 Digital Inputs, supporting major protocols like PROFINET, PROFIBUS, and Modbus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-73\"\u003e\u003c\/span\u003e\u003cstrong\u003eEnclosure and Protection:\u003c\/strong\u003e\u003cspan class=\"citation-73 citation-end-73\"\u003e\u003cspan\u003e \u003c\/span\u003eRated at IP21 (NEMA Type 1) as standard, providing essential protection against dust and vertical water drops in controlled industrial environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACS880-01-025A-3 (3AUA0000107992)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 to 415 V (3-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Power (Normal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current (Normal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47.5 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency converter \u0026lt;= 1 kV (ETIM 9\/10)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e409 mm x 155 mm x 249 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 40 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Heavy-Duty rating (IHD) affect application selection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor high-starting torque applications like cranes or mixers, the drive should be sized based on the Heavy-Duty rating of 17 A (7.5 kW). This ensures the drive can handle the thermal stress of frequent overloads without tripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the built-in choke in this R2 frame size?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal choke significantly reduces the harmonics reflected back into the power grid. This not only meets regulatory standards but also reduces the heating of upstream transformers and cables, extending the life of your electrical infrastructure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in hazardous environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-72 citation-end-72\"\u003eWhile the standard unit is IP21, the ACS880-01 series can be ordered with enclosure classes up to IP55.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-71 citation-end-71\"\u003eFor specific hazardous area requirements (ATEX), ensure the drive is used in conjunction with ABB’s certified safety functions and appropriate motor protection.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management and Clearance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACS880-01-025A-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egenerates heat during operation, especially when running at the full 25 A capacity. Maintain a minimum clearance of 200 mm above and 300 mm below the unit to ensure adequate airflow through the cooling fans. If mounting multiple drives in a cabinet, ensure the total heat dissipation (approx. 5.8 watts\/amp) is accounted for in your cabinet's climate control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and EMC Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo minimize electromagnetic interference, use symmetrical shielded motor cables. Ensure the cable shield is grounded 360 degrees at both the drive and the motor ends.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-70 citation-end-70\"\u003eFor long cable runs, consider an optional external output filter to protect the motor insulation from voltage spikes (dU\/dt).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning and Functional Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive features a USB port for easy connection to the Drive composer PC tool. Before initial startup, verify that the STO (Safe Torque Off) circuit is correctly wired. STO is a standard safety feature that prevents the drive from generating torque, ensuring a safe state for maintenance without disconnecting the main power.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701960241515,"sku":"ACS880-01-025A-3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/acs880-01-025a-3-bioux5hht4m_f8f30dca-3436-4756-91eb-5b3f069534d7.jpg?v=1766478208","url":"https:\/\/www.plcprotech.com\/fr\/products\/acs880-01-025a-3-abb-3aua0000107992-industrial-single-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}