{"product_id":"allen-bradley-1756-l73-controllogix-8-mb-controller","title":"Contrôleur ControlLogix 8 Mo Allen-Bradley 1756-L73","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-L73\u003c\/strong\u003e is a ControlLogix 5570 programmable automation controller designed to deliver high-performance control and data processing for demanding industrial automation applications. Equipped with \u003cstrong\u003e8 MB\u003c\/strong\u003e of user memory and \u003cstrong\u003e0.98 MB\u003c\/strong\u003e of dedicated I\/O memory, the \u003cstrong\u003e1756-L73\u003c\/strong\u003e provides real-time control, high-speed data execution, and seamless integration across complex architectures. Featuring an integrated USB programming port and pre-installed Secure Digital (SD) non-volatile memory storage, it provides robust, flexible controller performance within the ControlLogix 1756 platform.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 8 MB of user memory and 0.98 MB of dedicated I\/O memory\u003c\/li\u003e\n\u003cli\u003eSupports up to 32 controller tasks with up to 1000 programs per task\u003c\/li\u003e\n\u003cli\u003eIncludes 1 GB Secure Digital (SD) card (1784-SD1) for non-volatile memory storage\u003c\/li\u003e\n\u003cli\u003eEquipped with a USB 2.0 full-speed front port for local programming and configuration\u003c\/li\u003e\n\u003cli\u003eUtilizes capacitor-based energy storage modules (1756-ESMCAP) eliminating the need for lithium batteries\u003c\/li\u003e\n\u003cli\u003eSupports up to 128,000 digital I\/O and 4,000 analog I\/O points\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed batch processing and discrete manufacturing control\u003c\/li\u003e\n\u003cli\u003ePlant-wide process control and complex motion management\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment facility automation\u003c\/li\u003e\n\u003cli\u003eOil, gas, and energy generation control systems\u003c\/li\u003e\n\u003cli\u003eAutomated material handling and packaging machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-L73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5570 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Memory\u003c\/td\u003e\n\u003ctd\u003e0.98 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB Secure Digital (SD) card (1784-SD1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e4,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw at 1.2V DC\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw at 5.1V DC\u003c\/td\u003e\n\u003ctd\u003e800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.5 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 full-speed (12 Mbps), Type B connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 full-speed programming\/configuration port (Type B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003eControlLogix 1756 backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn off chassis power or verify area non-hazardous status before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the controller module with the top and bottom guides of any available chassis slot.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly into the slot until the top and bottom levers snap into position.\u003c\/li\u003e\n\u003cli\u003eEnsure the energy storage module (1756-ESMCAP) is securely seated in the controller unit.\u003c\/li\u003e\n\u003cli\u003eConnect the USB programming cable only for temporary local configuration and maintenance access.\u003c\/li\u003e\n\u003cli\u003eMaintain clear ventilation paths above and below the chassis to prevent thermal buildup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ec-UL-us Listed Industrial Control Equipment (UL File E65584)\u003c\/li\u003e\n\u003cli\u003eUL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E194810)\u003c\/li\u003e\n\u003cli\u003eCE Marked for European Union EMC Directives (EN 61326-1, EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003eRCM Australian Radiocommunications Compliance\u003c\/li\u003e\n\u003cli\u003eKC Korean Class A EMC Certification\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185457515,"sku":"1756-L73","price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1756-L73_2.jpg?v=1783590474","url":"https:\/\/www.plcprotech.com\/fr\/products\/allen-bradley-1756-l73-controllogix-8-mb-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}