{"product_id":"allen-bradley-1756-m16se-controllogix-sercos-interface-module","title":"Module d'interface SERCOS Allen-Bradley 1756-M16SE ControlLogix","description":"\u003cp\u003eThe \u003cstrong\u003e1756-M16SE\u003c\/strong\u003e is a chassis-based motion control module that enables multi-axis closed-loop servo synchronization through a centralized network setup. This interface hardware links software execution tracks inside a central processing host directly to distributed smart drives by establishing a single digital fiber-optic medium connection, eliminating up to 18 traditional discrete signal wires for every single active axis. The device supports real-time transmission vectors across \u003cstrong\u003eSERCOS interface\u003c\/strong\u003e parameters, delivering bidirectional cyclic communication loops to update position command points and upload diagnostic telemetry arrays simultaneously. Architected to operate within standard system racks, the module plugs directly into any available linear slot to control up to 16 independent servo drives under strict position, velocity, or torque loops.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Link Optoelectronic Port\u003c\/strong\u003e: Employs a digital fiber-optic communication terminal to replace complex multi-wire discrete physical bundles per axis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Synchronized Control\u003c\/strong\u003e: Manages closed-loop operational variables for up to 16 independent servo drive units simultaneously from one slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Drive Operating Modes\u003c\/strong\u003e: Supports flexible control switching profiles including real-time position, velocity, and torque regulation loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Agility\u003c\/strong\u003e: Mounts directly into any standard system rack position to match custom configuration blueprints.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Cyclic Diagnostics\u003c\/strong\u003e: Maintains a continuous double-sided feedback stream between controller and drive for tracking fault states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis coordinated packaging lines and sorting conveyor systems.\u003c\/li\u003e\n\u003cli\u003eHigh-precision positioning tables and material handling pick-and-place systems.\u003c\/li\u003e\n\u003cli\u003eSynchronized winding machinery, textile production, and continuous web handling.\u003c\/li\u003e\n\u003cli\u003eClosed-loop servo feed control in automotive and heavy assembly machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-M16SE \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSERCOS Interface Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Drives, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSERCOS Data Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Mbps or 8 Mbps \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSERCOS Cycle Time @ 4 Mbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 ms (up to 2 drives), 1 ms (up to 4 drives), 2 ms (up to 8 drives) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSERCOS Cycle Time @ 8 Mbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 ms (up to 4 drives), 1 ms (up to 8 drives), 2 ms (up to 16 drives) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Control Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePosition, velocity, and torque \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw @ 5.1V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw @ 24V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis-based, any slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Chassis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Power Supplies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-PA72\/C, 1756-PA75\/B, 1756-PB72\/C, 1756-PB75\/B, 1756-PC75\/B, 1756-PH75\/B \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Power Supplies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-PA75R, 1756-PB75R, 1756-PSCA2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlastic Fiber-Optic Cables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2090-SCEPxx-0 (non-jacketed CPE), 2090-SCVPxx-0 (standard PVC), 2090-SCNPxx-0 (nylon jacket) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlass Fiber-Optic Cables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2090-SCVGxx-0 (standard PVC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (open-style) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC (32 degF to 140 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC (-40 degF to 185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% noncondensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration (IEC 60068-2-6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g @ 10 to 500 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock (IEC 60068-2-27)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Shock (IEC 60068-2-27)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment\u003c\/strong\u003e: Ensure the keying tabs match the target rack slot before inserting the hardware to prevent twisting the inner connector path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber-Optic Cable Radius Constraints\u003c\/strong\u003e: Maintain the official minimal bend boundaries when pulling the core plastic or glass fiber lines to prevent high optical loss profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation Passages\u003c\/strong\u003e: Verify that surrounding cable trays do not block upper or lower chassis slots, preserving natural convective cooling across the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Sizing Requirements\u003c\/strong\u003e: Sum the combined 5.1 VDC and 24 VDC backplane current draws before initializing startup routines to prevent overcurrent trips.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us\u003c\/strong\u003e: UL Listed Industrial Control Equipment, certified for US and Canada (See UL File E65584); UL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE\u003c\/strong\u003e: European Union 2004\/108\/IEC EMC Directive, compliant with EN 61326-1 (Meas.\/Control\/Lab., Industrial Requirements), EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions), and EN 61136-2 (Programmable Controllers Clause 8, Zone A \u0026amp; B).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick\u003c\/strong\u003e: Australian Radiocommunications Act, compliant with AS\/NZS CISPR 11 (Industrial Emissions).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum number of servo axes this specific model can handle simultaneously?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eA: This module can handle a maximum of 16 drives or motion axes across the optical loop configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this interface link transmit torque control commands directly to a compatible servo drive?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eA: Yes, it inherently supports full position, velocity, and torque regulation modes across the real-time communication ring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of fiber-optic cables can be applied to link the module to field drives?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eA: It supports specified 2090 series cables, including non-jacketed CPE, standard PVC, nylon-jacketed plastic options, and standard PVC glass fiber lines.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695185850731,"sku":"1756-M16SE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-m16se-sercos-interface-module-efjujxlwuu0_b6f8859f-1320-44ab-b1ee-a3bcc428b823.jpg?v=1766114456","url":"https:\/\/www.plcprotech.com\/fr\/products\/allen-bradley-1756-m16se-controllogix-sercos-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}