{"product_id":"allen-bradley-2094-bc01-m01-s-kinetix-6000-integrated-axis-module","title":"Module d'axe intégré Allen-Bradley 2094-BC01-M01-S Kinetix 6000","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e2094-BC01-M01-S\u003c\/strong\u003e is a \u003cstrong\u003eKinetix 6000 integrated axis module\u003c\/strong\u003e combining converter and inverter sections within a modular multi-axis servo system. The 400V-class module supplies DC bus power and controls a connected servo axis.\u003c\/p\u003e\n\u003cp\u003eThe module accepts three-phase AC input within a specified range of 324 to 528 Vrms. Its nominal AC input ratings are 360V AC and 480V AC. The converter section provides 6 kW of continuous output power to the DC bus. The inverter section provides 9 A of continuous output current.\u003c\/p\u003e\n\u003cp\u003eAn integrated \u003cstrong\u003eSERCOS interface\u003c\/strong\u003e supports fiber-optic communication in linear or ring network topologies. Compatible interface devices include the 1756-MxxSE ControlLogix module, 1768-M04SE CompactLogix module, and 1784-PM16SE PCI communication card.\u003c\/p\u003e\n\u003cp\u003eThe drive receives feedback signals from compatible rotary motors, linear motors, and linear actuators. Supported motor families include Kinetix MP, Kinetix TL\/TLY, Kinetix RDB, 1326AB, and F-Series motors. Supported linear products include LDC-Series and LDL-Series motors and LDAT-Series linear actuators.\u003c\/p\u003e\n\u003cp\u003eIntegrated \u003cstrong\u003eSafe Torque-Off\u003c\/strong\u003e functionality prevents motor torque production after the safety circuit is tripped. The module mounts directly on a Kinetix power rail for installation within a multi-axis drive assembly.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated converter and inverter sections\u003c\/li\u003e\n\u003cli\u003e400V-class Kinetix 6000 architecture\u003c\/li\u003e\n\u003cli\u003eIntegrated SERCOS fiber-optic communication\u003c\/li\u003e\n\u003cli\u003eSupports linear and ring SERCOS topologies\u003c\/li\u003e\n\u003cli\u003eIntegrated Safe Torque-Off functionality\u003c\/li\u003e\n\u003cli\u003eCompatible with rotary motors, linear motors, and linear actuators\u003c\/li\u003e\n\u003cli\u003eSupports peak torque up to 250% of continuous rated current\u003c\/li\u003e\n\u003cli\u003ePower-rail mounting within a multi-axis drive assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-axis packaging machinery\u003c\/li\u003e\n\u003cli\u003eMaterial handling equipment\u003c\/li\u003e\n\u003cli\u003eAutomated assembly systems\u003c\/li\u003e\n\u003cli\u003eConverting and printing machinery\u003c\/li\u003e\n\u003cli\u003eServo-controlled production equipment\u003c\/li\u003e\n\u003cli\u003eLinear motion systems\u003c\/li\u003e\n\u003cli\u003eCoordinated rotary motion applications\u003c\/li\u003e\n\u003cli\u003eMachine automation using SERCOS motion control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrderable Model\u003c\/th\u003e\n\u003cth\u003eSeries and Revision\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2094-BC01-M01-S Ser A\u003c\/td\u003e\n\u003ctd\u003e2094-BC01-M01-S\/A, Series A, Rev A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2094-BC01-M01-S Ser B\u003c\/td\u003e\n\u003ctd\u003e2094-BC01-M01-S\/B, Series B, Rev B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2094-BC01-M01-S Ser C\u003c\/td\u003e\n\u003ctd\u003e2094-BC01-M01-S\/C, Series C, Rev C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Line\u003c\/th\u003e\n\u003ctd\u003eKinetix 6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003e2094-BC01-M01-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e820919595653\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eIntegrated Axis Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Configuration\u003c\/th\u003e\n\u003ctd\u003eIntegrated converter and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Class\u003c\/th\u003e\n\u003ctd\u003e400V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Input Voltage Range\u003c\/th\u003e\n\u003ctd\u003e324 to 528 Vrms, three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal AC Input Voltage\u003c\/th\u003e\n\u003ctd\u003e360V AC \/ 480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Input Voltage\u003c\/th\u003e\n\u003ctd\u003e458 to 747V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine Frequency\u003c\/th\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuous Output Power to Bus\u003c\/th\u003e\n\u003ctd\u003e6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuous Inverter Output Power\u003c\/th\u003e\n\u003ctd\u003e3.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuous Inverter Output Current\u003c\/th\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak Output Power\u003c\/th\u003e\n\u003ctd\u003e12 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus Overvoltage\u003c\/th\u003e\n\u003ctd\u003e425V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus Undervoltage\u003c\/th\u003e\n\u003ctd\u003e275V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication Interface\u003c\/th\u003e\n\u003ctd\u003eSERCOS fiber-optic interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupported Network Topologies\u003c\/th\u003e\n\u003ctd\u003eLinear and ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003ePower rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Clearance\u003c\/th\u003e\n\u003ctd\u003e50.8 mm (2.0 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Enclosure Depth\u003c\/th\u003e\n\u003ctd\u003e198 mm (7.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension A\u003c\/th\u003e\n\u003ctd\u003e272 mm (10.7 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension B\u003c\/th\u003e\n\u003ctd\u003e249 mm (9.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension D\u003c\/th\u003e\n\u003ctd\u003e0 mm (0 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension E\u003c\/th\u003e\n\u003ctd\u003e256 mm (10.1 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension F\u003c\/th\u003e\n\u003ctd\u003e287 mm (11.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e12.00 lb (5.44 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe dimensional values correspond to the module mounted on the Bulletin 2094 power rail. :contentReference[oaicite:0]{index=0}\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on the specified Bulletin 2094 power rail.\u003c\/li\u003e\n\u003cli\u003eProvide at least 50.8 mm (2.0 in.) of installation clearance.\u003c\/li\u003e\n\u003cli\u003eUse an enclosure with a minimum depth of 198 mm (7.8 in.).\u003c\/li\u003e\n\u003cli\u003eMaintain the required clearance for cable connectors and bend radii.\u003c\/li\u003e\n\u003cli\u003eRoute fiber-optic cables without exceeding their permitted bend radius.\u003c\/li\u003e\n\u003cli\u003eProtect SERCOS fiber connections from contamination and mechanical damage.\u003c\/li\u003e\n\u003cli\u003eVerify the three-phase AC supply before energizing the module.\u003c\/li\u003e\n\u003cli\u003eConfirm that the selected motor and feedback configuration are compatible with the drive.\u003c\/li\u003e\n\u003cli\u003eComplete grounding and bonding before applying power.\u003c\/li\u003e\n\u003cli\u003eRemove power before installing or replacing the module on the power rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Function\u003c\/th\u003e\n\u003ctd\u003eSafe Torque-Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunctional Safety Rating\u003c\/th\u003e\n\u003ctd\u003eISO 13849-1 PLe \/ SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEN 954-1 Category 3 Applications\u003c\/th\u003e\n\u003ctd\u003eAn external safety relay may be required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695188636011,"sku":"2094-BC01-M01-S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-2094-bc01-m01-s-integrated-axis-module-bisd2cyisae_ec1018a6-f221-43e7-bcd2-8e24d64b9fab.jpg?v=1766114549","url":"https:\/\/www.plcprotech.com\/fr\/products\/allen-bradley-2094-bc01-m01-s-kinetix-6000-integrated-axis-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}