{"product_id":"allen-bradley-5069-ib16-compact-5000-digital-input-module","title":"Module d'entrée numérique Compact 5000 Allen-Bradley 5069-IB16","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital DC input module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Compact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It is designed to interface with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix 5580\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(via remote EtherNet\/IP) controllers. Featuring 16 sinking inputs, this module is optimized for high-speed industrial applications where fast response times and precise signal detection are critical for machine performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Sinking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\/24V DC Sink\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10V DC (Min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA (Min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ms to 30000 ms (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 18–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor\/Actuator Power (SA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA @ 18–32V DC (plus field load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Speed Processing\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAs part of the Compact 5000 I\/O platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides significantly faster I\/O-to-backplane communication speeds compared to older 1769 or 1734 platforms. This ensures that the controller receives input state changes with minimal latency, improving the accuracy of high-speed sensors and registration marks.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Sinking Input Design\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSinking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, meaning it provides a path to the negative common for the connected device. This is the standard interface for \"Sourcing\" (PNP) field sensors.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Extensive Diagnostics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 5069-IB16 features advanced diagnostic capabilities. Through Studio 5000, engineers can monitor:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Health:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStatus of the backplane connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power Status:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetection of whether field-side power is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput State LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual green status indicators for each of the 16 channels, located on the front of the module for immediate physical troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Removable Terminal Block (RTB) does this module use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069-IB16 is compatible with the 18-pin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(screw-clamp) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(push-in style) terminal blocks. Note that RTBs are typically sold separately from the I\/O module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support RIUP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Like other Compact 5000 I\/O modules, it supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e, allowing you to replace the module without shutting down the entire system or disconnecting field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto be fed through the controller or the field potential distributor. This power is used to provide the voltage for the inputs and the field-side circuitry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded cable for inputs that are subjected to high electromagnetic interference (EMI). Ensure that the SA power common is correctly tied to the sensor common to establish a complete circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Settings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjust the digital filter settings in Studio 5000 to eliminate \"contact bounce\" from mechanical limit switches. For high-speed proximity sensors, set the filter time to the minimum (0 ms) to capture rapid pulses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting 16-point modules side-by-side, ensure the enclosure has adequate ventilation. The 5069 series utilizes passive convection cooling and requires at least 50mm of clearance above and below the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis favored for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEfficiency and Reliability\u003c\/strong\u003e. By providing 16 points in a very slim profile, it allows for high-density I\/O configurations in small control cabinets. Its deterministic performance makes it the standard choice for modern Allen-Bradley architectures where the goal is to synchronize high-speed I\/O with CIP Motion or complex safety logic.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084451799403,"sku":"5069-IB16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-IB16_2.png?v=1775995151","url":"https:\/\/www.plcprotech.com\/fr\/products\/allen-bradley-5069-ib16-compact-5000-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}