{"product_id":"allen-bradley-5069-l310er-nse-compactlogix-5380-no-stored-energy-controller","title":"Contrôleur CompactLogix 5380 sans énergie stockée Allen-Bradley 5069-L310ER-NSE","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized version of the CompactLogix 5380 controller designed for environments where \"stored energy\" is a safety or security risk. While it retains the core high-performance characteristics of the 5380 series, it is specifically engineered for hazardous or restricted areas—such as mining, explosives manufacturing, or highly secure data centers—where traditional energy-storing capacitors are prohibited.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNSE Feature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNo Stored Energy\u003c\/strong\u003e (No internal capacitors\/batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 24 Ethernet\/IP nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. No Stored Energy (NSE) Technology\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eStandard CompactLogix controllers use internal energy storage modules (capacitors) to write data to non-volatile memory during a power loss. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNSE version\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eremoves these components. This ensures that when power is cut, the energy dissipated is below the threshold required to trigger an ignition in explosive atmospheres, meeting strict\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Area\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntrinsically Safe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Dual Gigabit Ethernet \u0026amp; High-Speed Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eDespite its specialized safety features, it maintains the performance of the 5380 series:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGigabit Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual 1-Gbps ports support high-speed data exchange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for network segmentation, isolating machine-level I\/O traffic from higher-level enterprise networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDLR Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Device Level Ring for high network availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. High-Speed 5069 Backplane\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIt utilizes the 5069 Compact I\/O platform, which provides much faster scan times and higher accuracy for time-critical applications compared to the older 1769 series.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the NSE version handle data during power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elacks the internal energy to write data to the SD card during an unexpected power down, any data not already saved to the non-volatile memory (or synchronized to a SCADA\/DB system) will be lost. In these applications, engineers typically use an external Uninterruptible Power Supply (UPS) if data retention is critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this for motion control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edoes not have the \"M\" designation. If you require integrated motion in a no-stored-energy format, you would need to look for an \"ERM-NSE\" variant, though the L310ER-NSE is primarily used for discrete and process logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" and \"MOD Power\" on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069 architecture separates the power feeds:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers the internal controller logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers the field-side circuitry of the I\/O modules. Both must be wired via a removable terminal block (RTB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Dependency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this unit cannot back itself up, ensure your application logic is designed for \"clean\" restarts. Use the 1784-SD2 card to store the project, but be aware that tag values will revert to their last saved state upon power cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard horizontal DIN rail mounting. Like other 5380 controllers, it requires adequate spacing for thermal dissipation as the high-speed processor generates significant heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NSE series is frequently mandated in secure government or military facilities where the ability of a device to hold a charge (and thus potentially maintain data in memory) after power removal is viewed as a security vulnerability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the industry standard for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Location Safety\u003c\/strong\u003e. It allows plant managers to deploy a high-speed, modern Logix controller into zones where they previously had to rely on older, less capable technology. By eliminating stored energy, Rockwell has provided a path to modernize explosives handling, chemical processing, and underground mining operations without compromising safety protocols.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53083971518827,"sku":"5069-L310ER-NSE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L310ER-NSE.png?v=1775993302","url":"https:\/\/www.plcprotech.com\/fr\/products\/allen-bradley-5069-l310er-nse-compactlogix-5380-no-stored-energy-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}