{"product_id":"allen-bradley-5069-l310erms2-compact-guardlogix-5380-sil-2-controller","title":"Contrôleur Compact GuardLogix 5380 SIL 2 Allen-Bradley 5069-L310ERMS2","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance safety controller from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It provides integrated control for both standard and safety-related industrial applications, achieving safety ratings up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2 \/ PLd (Category 3)\u003c\/strong\u003e. This controller is designed for machine builders who require a single, compact unit to manage complex logic, high-speed I\/O, and motion, while simultaneously ensuring functional safety for personnel and equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIL 2 \/ PLd (Category 3)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to \u003cstrong\u003e4 axes\u003c\/strong\u003e (CIP Motion over EtherNet\/IP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e24 nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v31 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Integrated Safety \u0026amp; Standard Control\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for a separate safety PLC. It uses a \"1oo2\" (one out of two) internal architecture to monitor and execute safety functions. In Studio 5000, safety logic is kept in a dedicated \"Safety Task\" with restricted access, ensuring that standard code modifications do not inadvertently affect safety signatures.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Integrated Motion on EtherNet\/IP\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \"M\" in the catalog number signifies integrated motion support. It can coordinate up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 axes of CIP Motion\u003c\/strong\u003e, allowing for synchronized control of Kinetix servo drives. Crucially, this includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCIP Safety over EtherNet\/IP\u003c\/strong\u003e, enabling safe speed, safe direction, and safe torque off (STO) functions to be managed over the same network cable as the standard control data.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. High-Speed Performance \u0026amp; Dual Gigabit Ethernet\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for the physical separation of safety\/I\/O traffic from the higher-level enterprise network, which is vital for maintaining safety determinism and cybersecurity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDLR Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Device Level Ring topologies to ensure that a single cable failure does not drop the safety connection, preventing nuisance trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 5069-L310ERM and the 5069-L310ERMS2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a standard controller with motion support. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadds a dedicated 0.5 MB safety memory partition and the internal diagnostics required to be certified for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard 5069 I\/O modules with this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can mix standard 5069 I\/O modules for non-safety tasks and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB8S \/ OBV8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety modules for safety tasks in the same local rack or on the same remote EtherNet\/IP network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller require a safety partner module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Unlike the older 1756 GuardLogix systems that required a primary and a safety partner, the Compact GuardLogix 5380 series (like the L310ERMS2) is a self-contained safety controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Signatures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnce the safety logic is validated, the controller generates a unique safety signature. Any change to the safety code changes this signature, providing a clear audit trail for regulatory compliance (e.g., OSHA or CE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLike other 5069 units, it requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for logic) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for field-side I\/O power). Use high-quality DC power supplies to ensure the safety bus remains stable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller is designed for an operating temperature range of 0 to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e60°C\u003c\/span\u003e. In safety applications, ensure that cabinet cooling is adequate, as the safety processor performs intense internal self-diagnostics that generate additional heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084049211755,"sku":"5069-L310ERMS2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L310ERMS2_2.png?v=1775994732","url":"https:\/\/www.plcprotech.com\/fr\/products\/allen-bradley-5069-l310erms2-compact-guardlogix-5380-sil-2-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}