{"product_id":"allen-bradley-5069-ob16-compact-5000-digital-output-module","title":"Module de sortie numérique Compact 5000 Allen-Bradley 5069-OB16","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital DC output module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Compact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. It features 16 sourcing outputs and is designed for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix 5580\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(via a 5069-AENTR) controllers. This module is engineered for high-speed switching of industrial actuators, such as solenoid valves, motor starters, and indicator lights, providing a fast and deterministic interface for modern automated systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC Source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per channel (8 A max per module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurge Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A for 10 ms per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 18–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor\/Actuator Power (SA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA @ 18–32V DC (plus field load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Sourcing Output Architecture\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSourcing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesign, meaning the module provides the positive voltage (+24V DC) to the load. The other side of the load is typically connected to the common (ground). This is the most common output configuration for driving industrial components in a PNP-compatible circuit.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. High-Speed Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePart of the Compact 5000 platform, this module benefits from a high-speed system backplane that ensures output commands from the controller are executed with minimal latency. This is essential for applications requiring precise timing, such as high-speed sorting or synchronized packaging movements.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Advanced Module Diagnostics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 5069-OB16 provides real-time diagnostic information to the controller, which can be viewed in Studio 5000:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetects if the field-side power supply is missing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Status LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures individual green status LEDs for each of the 16 channels, allowing for rapid visual troubleshooting on the factory floor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes built-in protection against overcurrent and short-circuit conditions on a per-module basis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Removable Terminal Block (RTB) is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is compatible with the 18-pin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(screw-clamp) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(push-in) terminal blocks. Note that these are typically ordered separately from the module itself.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support RIUP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e, which allows maintenance personnel to swap out a module without powering down the entire chassis or disconnecting the field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be supplied to the module through the controller or a field potential distributor. This power is used to energize the output circuits and the physical devices (solenoids, etc.) connected to them.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor inductive loads (like solenoids or relays), it is standard practice to use an external surge suppressor (flyback diode) across the load to protect the module’s internal transistors from back-EMF spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen switching high-current loads across all 16 channels simultaneously, ensure the cabinet has sufficient ventilation. Maintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below the module for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Tie-In:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the SA Power common is correctly tied to the load common to complete the electrical circuit for the sourcing outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis highly valued for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHigh Density and Reliability\u003c\/strong\u003e. By providing 16 points in a slim 22mm wide module, it allows for significant I\/O expansion in space-constrained control cabinets. Its deterministic integration with the Logix 5000 environment ensures that even complex, multi-output sequences are executed with the precision required for high-performance IIoT-ready machinery.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084747956587,"sku":"5069-OB16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-OB16.png?v=1775996986","url":"https:\/\/www.plcprotech.com\/fr\/products\/allen-bradley-5069-ob16-compact-5000-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}