{"product_id":"allen-bradley-5069-rtb18-screw-removable-terminal-block","title":"Bloc de bornes amovible Allen-Bradley 5069-RTB18-SCREW","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 18-pin removable terminal block (RTB) designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It serves as the physical interface between the field-side wiring and the I\/O modules or controllers. The \"SCREW\" designation indicates that this model utilizes traditional screw-clamp terminations, providing a high-torque, secure connection for industrial environments where vibration resistance and wiring reliability are paramount.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Pins\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTorque Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 N·m (3.5 lb·in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size (Solid)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–12 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size (Stranded)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–14 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A per pin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functionalities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Density Connectivity\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 18-pin layout is designed to match the high-density architecture of the 5069 I\/O series. It allows for the termination of multiple signal and return wires on a single block, maximizing cabinet space.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Removable Architecture (RIUP)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eA key feature of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e. This allows maintenance personnel to replace a faulty I\/O module without disconnecting the field wiring, significantly reducing Mean Time to Repair (MTTR) and preventing wiring errors during hardware swaps.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Secure Screw Termination\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eUnlike the \"SPRING\" (push-in) variants, the screw-clamp mechanism ensures a gas-tight connection that is highly resistant to mechanical loosening. This makes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe preferred choice for applications in heavy manufacturing, mining, and oil \u0026amp; gas where equipment is subject to constant physical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 5069-RTB18-SCREW compatible with all 5069 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is compatible with many 5069 discrete and analog modules, but you must verify the pin count. Some specialized modules require 14-pin blocks (\u003cstrong\u003e5069-RTB14\u003c\/strong\u003e). Always check the specific I\/O module's technical data sheet to ensure 18 pins are supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix screw and spring terminal blocks in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The choice of RTB is module-specific. You can use a screw-type RTB for an analog input module and a spring-type RTB for a discrete output module within the same\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a special tool for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA standard small flat-head screwdriver (typically 3.5 mm) is required to tighten the clamps to the recommended torque of 0.4 N·m.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOver-tightening can damage the internal clamp, while under-tightening can lead to intermittent signals or arcing. Using a calibrated torque screwdriver is recommended for safety-critical circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Preparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip the wire insulation back approximately 10–12 mm. For stranded wire, the use of ferrules is highly recommended to prevent fraying and ensure a clean insertion into the clamp.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeying:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5069 series supports mechanical keying. It is best practice to use the keying tabs to prevent an RTB wired for high voltage from being accidentally inserted into a low-voltage analog module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis favored for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRobustness and Versatility\u003c\/strong\u003e. In global industrial markets, screw terminals are often mandated by local electrical standards for their visibility—an engineer can visually verify that a screw is tightened, providing an extra layer of confidence during commissioning. By isolating the wiring from the electronic module, Rockwell has created a modular system that simplifies both the initial build and long-term maintenance of the control cabinet.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084005564779,"sku":"5069-RTB18-SCREW","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Allen-Bradley5069-RTB18-SCREW.png?v=1775993709","url":"https:\/\/www.plcprotech.com\/fr\/products\/allen-bradley-5069-rtb18-screw-removable-terminal-block","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}