{"product_id":"alstom-esvi1-l54e1100bb-logic-analog-i-o-card","title":"Carte d'E\/S analogique logique ALSTOM ESVI1 L54E1100BB","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESVI1 (ESVI-1)\u003c\/strong\u003e, identified by the specific part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL54E1100BB (L54E1100BB00)\u003c\/strong\u003e, is a high-integrity vital safety I\/O card engineered for ALSTOM’s mission-critical rail signaling and industrial safety systems. As a SIL4-certified component, this module is designed to handle \"vital\" logic where failure-to-safety is the absolute priority. Frequently deployed in interlocking systems and train control units, the ESVI1 manages the high-speed acquisition of field-side signals and the execution of safety-critical commands. By utilizing the L54E1100BB in your control architecture, you ensure a deterministic response to field conditions, effectively bridging the gap between field instrumentation and vital logic processing with a focus on maximum operational safety.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe ESVI1 L54E1100BB is built upon a redundant, fail-safe hardware platform compliant with CENELEC EN 5012x and IEC 61508 standards.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a dual-channel \"2-out-of-2\" internal logic structure. This ensures that every input signal is cross-verified by independent processing paths before a logical state is confirmed, preventing nuisance trips or unsafe failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides high-level 1500 VAC isolation between the field-side I\/O channels and the system backplane, shielding the central processor from ground loops and external electrical transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrimarily interfaces via the ALSTOM SAFEBUS or high-speed FIP\/WorldFIP backplane protocols, allowing for real-time data exchange with sub-10 ms response times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed with relay-based or high-security open-collector (OC) outputs that are monitored for \"stuck-at\" faults and cross-circuit integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESVI1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eL54E1100BB \/ L54E1100BB00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eALSTOM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL4 (CENELEC EN 5012x \/ IEC 61508)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-24 Input Channels \/ 8-16 Output Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (18-30 VDC range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 deg C (EN 50155 Class TX)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 10 ms (Input-to-Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e185 x 185 x 105 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the significance of the \"Vital Safety\" designation for the ESVI1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis means the module is hardware-validated for functions where a failure could lead to catastrophic consequences. It utilizes built-in self-tests and redundant logic to ensure a fail-safe state under all conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this module operate in unconditioned outdoor cabinets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the L54E1100BB is rated for EN 50155 Class TX, which supports a wide temperature range from -40 to 70 deg C, making it suitable for trackside signaling bungalows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How does the module indicate an internal safety fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe front panel status LEDs will trigger a specific \"FAULT\" or \"VITAL ERR\" code, and the module will automatically de-energize its safety outputs to ensure the controlled system enters a known safe state.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Seating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the ESVI1 is fully inserted into the SAFEBUS backplane. Use the captive screws to secure the module; a loose connection on a vital card can trigger a system-wide emergency stop due to lost heartbeat signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen wiring for SIL4 applications, ensure that the field-side power supply is also redundant and that input wiring follows the \"dual-path\" segregation rules to prevent common-mode failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor screw-terminal interface blocks, maintain a torque of 0.4 Nm. Over-tightening can damage the safety-rated internal trace headers, while under-tightening can lead to signal flickering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ALSTOM ESVI1 L54E1100BB represents the pinnacle of fail-safe engineering for the B2B rail and industrial sectors. Its PCB is protected by a military-grade conformal coating, providing resilience against humidity, salt spray, and vibration—essential for long-term reliability in transport infrastructure. With its rapid 10 ms response time and SIL4 certification, it provides engineers with the highest level of confidence in protecting both human life and high-value industrial assets.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Alstom","offers":[{"title":"Default Title","offer_id":52695207248235,"sku":"ESVI1 L54E1100BB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/alstom-esvi1-l54e1100bb-logic-analog-i-o-card-a0fe4f0kdsy_3a16af60-6f91-4cb5-9cdc-889ec45714e8.jpg?v=1766130729","url":"https:\/\/www.plcprotech.com\/fr\/products\/alstom-esvi1-l54e1100bb-logic-analog-i-o-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}