{"product_id":"b-r-4xp0000-00-k43-x2x-link-operator-keypad-module","title":"B\u0026R 4XP0000.00-K43 Module clavier opérateur X2X","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R 4XP0000.00-K43 (4XP0000.00-K43)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a ruggedized, field-level X2X Link keyboard interface module engineered for direct machine interaction and safety integration. Developed for high-visibility deployment in material handling conveyors, automotive stamping cells, and industrial food processing plants, this high-integrity HMI component provides immediate tactile control and emergency override capabilities to eliminate operator latency and prevent critical mechanical asset damage. The unit integrates 6 high-visibility, multi-colored B\u0026amp;R illuminated ring keys alongside a dedicated physical Emergency Stop button, housed within a robust metal frame with a clean white aluminum front foil overlay. Operating natively as an X2X Link slave node, this interface distributes real-time button actuation telemetry and localized LED states across distances up to 100 m between stations, ensuring immediate control availability on expansive factory floors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe electrical architecture and ergonomic field layout of this keypad module focus on high-reliability control room feedback and physical durability:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePremium Tactile Switch Interfaces\u003c\/strong\u003e: Equipped with industrial Rafix 22FS+ series switch mechanisms featuring robust mechanical travel and highly predictable feedback profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVariable Multicolored LED Arrays\u003c\/strong\u003e: The 6 round illuminated ring keys feature distinct, independent internal color matrices to reflect varied machine operating conditions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2 Rings\u003c\/strong\u003e: Full spectrum configuration (Red, Yellow, Green, White).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3 Rings\u003c\/strong\u003e: Standard status configuration (Red, Yellow, Green).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1 Ring\u003c\/strong\u003e: Special function configuration (Red, Yellow, Green, Blue).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Contact Emergency Safety\u003c\/strong\u003e: The integrated E-stop button features two independent, hardwired Normally Closed (NC) contacts operating on an isolated 24 VDC control loop for direct integration into safety relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSevere Environment Protection\u003c\/strong\u003e: The front face is sealed with a naturally anodized aluminum frame and polyester foil overlay, securing NEMA 250 Type 4X and IP65 protection against dust, chemical mist, and high-pressure hose water.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4XP0000.00-K43\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAustria\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX2X Link Slave Node\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8-pin Male Multipoint Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Station Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTactile Key Components\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6x B\u0026amp;R Illuminated Ring Keys \/ 1x E-stop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitch Core Hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRafix 22FS+ (1.30.273.511\/0300)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eE-Stop Contact Block\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x Normally Closed (NC) Contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 25%, Galvanically Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 A for less than 1 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating (Front \/ Back)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65 \/ IP20 (NEMA Type 4X Front)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Operating Altitude\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 mm x 80 mm x 32 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e430 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the 20 A inrush current profile impact the upstream power distribution design?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal power supply circuit of the 4XP0000.00-K43 pulls a brief, intense inrush current spike up to 20 A for less than 1 ms during a cold boot power-up sequence. Upstream 24 VDC switch-mode power supplies (SMPS) or electronic circuit protectors must feature adequate overload capacity or appropriate tripping characteristics to handle this transient spike without dropping the voltage rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 6 illuminated ring keys be driven directly by the user application program?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The multi-colored LEDs embedded within the Rafix 22FS+ ring keys are completely mapped to the digital output process image of the B\u0026amp;R master controller via the X2X Link bus. Field engineers can write application logic in B\u0026amp;R Automation Studio to dynamically change key colors (e.g., green for ready, flashing yellow for warning, red for fault) based on automated process steps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the X2X Link communication line inside this module electrically isolated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module does not feature internal galvanic isolation for the X2X Link data lines. Ensure that the entire network share a common reference potential. When routing the 100 m bus lines across different factory zones, use shielded cables and proper ground bonding plates to counteract electromagnetic interference and ground potential differentials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering and Installation Directives\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eSAFETY LOOP COMPLIANCE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe physical Emergency Stop switch must be tested for mechanical operation and contact continuity weekly. The dual Normally Closed (NC) safety contacts must be routed directly to an approved safety evaluation relay or safety PLC, completely independent of the standard X2X Link data bus processing loop.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch4\u003ePanel Cutout and Gasket Seating Guide\u003c\/h4\u003e\n\u003cp\u003ePrepare a precise rectangular panel cutout according to the 170 mm x 80 mm dimensions. Before inserting the unit, inspect the flat neoprene sealing gasket around the inner display front for proper alignment and ensure it is entirely free of particulate debris. Insert the keypad assembly from the front of the console plate and tighten the rear retention clamps progressively to compress the gasket evenly. This step is critical to maintain the NEMA Type 4X and IP65 wash-down seal and prevent liquid entry into the internal electronics.\u003c\/p\u003e\n\u003ch4\u003eMultipoint Bus Wiring and Grounding\u003c\/h4\u003e\n\u003cp\u003eTerminate the incoming field connection via the integrated 8-pin male multipoint connector. Ensure the cable shield braid from the X2X Link network is stripped correctly and clamped firmly to the metal enclosure frame or the local cabinet functional ground (FE) rail. Keep the 24 VDC power and X2X communication signals separated from high-amperage AC contactor lines and variable frequency drive (VFD) motor output conductors inside the enclosure wire ducts to maximize signal fidelity.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086373577067,"sku":"4XP0000.00-K43","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/4xp000000k43-uvnxgjc2ovh.png?v=1776137127","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-4xp0000-00-k43-x2x-link-operator-keypad-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}