{"product_id":"b-r-8b0p0440hw00-000-1-acoposmulti-passive-power-supply-module","title":"B\u0026R 8B0P0440HW00.000-1 Module d'alimentation passive ACOPOSmulti","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8B0P0440HW00.000-1 (8B0P0440HW000001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity passive power supply module engineered for the B\u0026amp;R ACOPOSmulti drive system. This unit acts as the central energy entry point for the DC bus, converting a three-phase AC mains input into a stabilized DC voltage for multiple inverter modules. Designed for high-voltage (HV) applications and rated at 44 A, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8B0P0440HW00.000-1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for wall-mounting within control cabinets, providing a robust power foundation for large-scale automation lines, CNC machining centers, and heavy-duty material handling systems. Its passive design offers a cost-effective and reliable solution for systems that do not require regenerative energy recovery to the mains.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis power supply is characterized by its high power density and specific integration requirements for the ACOPOSmulti backplane.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Power Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports an installed load of up to 30.4 kVA, capable of powering several high-torque axes simultaneously across the shared DC bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePassive Rectification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes a ruggedized bridge rectifier circuit to provide a stable DC link from a 380-500 VAC input, characterized by a low inrush current of 10 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its high output, it maintains a low power dissipation of approximately 300 W at continuous power, supported by the efficient wall-mounting heat sink design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Discharge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an integrated discharge capacitance of 0.9 uF, essential for managing the energy levels of the DC bus during power-down sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8B0P0440HW00.000-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e44 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3x 380 to 3x 500 VAC (plus or minus 10 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 \/ 60 Hz (plus or minus 4 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstalled Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 30.4 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 300 W (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A (at 400 VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDischarge Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 uF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e263 mm (Wall Mounting)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 6.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum time required between power cycles?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8B0P0440HW00.000-1 requires a switch-on interval of greater than 120 seconds. This delay is critical to allow the internal inrush current limiting components to cool down and reset before the next power-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this passive module support energy regeneration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive power supply module. Any regenerative energy produced by the motors during deceleration must be dissipated via an external braking resistor or stored in a capacitor module; it cannot be fed back into the mains.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat size cabinet is required for the 263 mm mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 263 mm refers to the specialized wall-mounting width for the ACOPOSmulti rack. Ensure the cabinet depth and height can accommodate the 6.1 kg unit while allowing for the necessary vertical clearance for cooling.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation and Power Safety Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Bus Voltage Warning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWARNING: The DC bus carries lethal voltages (up to 800 VDC depending on mains input). After disconnecting the power, wait at least 5 minutes for the discharge capacitance to bring the bus voltage to a safe level before performing any service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the upstream circuit breakers are sized to handle the 10 A inrush current. Rapidly cycling the power (faster than the 120 s interval) will bypass the soft-start protection and may cause the primary fuse to blow or damage the rectifier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module weighs approximately 6.1 kg. Use the designated wall-mounting brackets and ensure the mounting surface is vibration-free. High-frequency vibration can lead to terminal fatigue on the high-current AC input connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse three-phase industrial cabling rated for at least 600 V and 50 A. The module must be grounded via the central grounding stud on the ACOPOSmulti rack to prevent common-mode noise from affecting the drive communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086375706987,"sku":"8B0P0440HW00.000-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8b0p0440hw00.000-1-f1ffmxarwnt.png?v=1776137176","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-8b0p0440hw00-000-1-acoposmulti-passive-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}