{"product_id":"b-r-v1022-00-2-acopos-1022-single-axis-servo-drive","title":"B\u0026R V1022.00-2 Servo-variateur mono-axe ACOPOS 1022","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe B\u0026amp;R\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV1022.00-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eV1022.00-2\u003c\/strong\u003e) is a compact single-axis servo drive belonging to the ACOPOS 1022 series, engineered for high-precision motion control in demanding industrial environments. It operates on a 3-phase mains input of 400 to 480 V AC and delivers a continuous output current of 2.2 A, supporting motors up to 1 kW. This drive is a core component in high-speed packaging machinery, printing presses, CNC machining centers, and robotic assembly lines where synchronized movement and minimal cycle times are critical. The unit integrates a line filter (EN 61800-3 Cat C3) and a braking resistor (3.5 kW peak) directly into the chassis, reducing cabinet footprint and external wiring complexity. An electronic secure restart inhibit prevents unintended machine startup after power restoration or fault clearing, enhancing personnel safety. With four expansion slots for plug-in modules (Encoder, I\/O, Fieldbus), the V1022.00-2 adapts to complex feedback and communication requirements, ensuring maximum machine uptime and simplified maintenance via plug-in terminal connections.\u003c\/p\u003e\n\u003ch3\u003eDrive Configuration and Integrated Features\u003c\/h3\u003e\n\u003cp\u003eThe V1022.00-2 utilizes a modular hardware platform designed for flexibility in panel layout and function expansion.\u003c\/p\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Stage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe drive handles an installed load of up to 3 kVA. It supports switching frequencies of 5, 10, or 20 kHz, allowing optimization between motor noise reduction and power loss. The DC bus capacitance is 235 uF.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety \u0026amp; Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes an integrated RFI filter for mains input and an integrated braking resistor (130 W continuous, 3.5 kW peak) for managing regenerative energy during rapid deceleration or vertical axis movements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour front-facing slots accommodate ACOPOS plug-in modules. Common configurations include the AC114 (Encoder Interface) for EnDat\/Hiperface feedback, AC119 (Digital I\/O), or AC112 (Ethernet POWERLINK) for real-time communication.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures 3 configurable digital inputs (24 VDC, sink) for limit switches and reference pulses, plus a dedicated Enable input. The motor interface supports temperature sensor (KTY84\/NTC) and holding brake connections directly on the terminal block.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eParameter\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eV1022.00-2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eB\u0026amp;R Industrial Automation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAustria\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApprox. 2.5 kg (Module only)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 mm x 260 mm x 210 mm (W x H x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 to 40 deg C (Nominal), up to 55 deg C (With Derating)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3x 400 - 480 V AC (+\/- 10%), 50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.2 Aeff\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e14 Aeff (short-term)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kW (1.3 HP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eInstalled Load\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3 kVA max\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 \/ 10 \/ 20 kHz (Selectable)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP20\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCE, cULus, KC, EAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the V1022.00-2 require an external line filter or braking resistor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Unlike older generations or higher power models, the V1022.00-2 integrates both the mains line filter (Category C3) and the braking resistor internally. This saves significant panel space and reduces wiring time, though for extremely high duty cycle regenerative applications, an external resistor can still be connected to the DC bus terminals if needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat communication protocols does this drive support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe base unit relies on the hybrid cabling system or optional plug-in modules. For standard operation, it connects via the B\u0026amp;R X2X Link or hybrid cable. For Ethernet-based control, you must install a plug-in module such as the AC112 (Ethernet POWERLINK) or third-party modules for EtherCAT\/CANopen into one of the four front slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive compatible with third-party servo motors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided the motor parameters (current, inductance, back-EMF) are within the drive's rating (2.2 A continuous, 14 A peak) and a suitable encoder interface module is used. B\u0026amp;R recommends pairing with 8LS series servo motors for optimal performance, but the drive accepts resolver, EnDat, BiSS, and Hiperface feedback via the appropriate plug-in card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes the \"Derating\" condition at higher temperatures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbove 40 deg C ambient temperature, the output current capability decreases linearly (approx. 2.2 Aeff reduction per 15 deg C increase, depending on voltage setting) to prevent overheating of the power semiconductors. Proper cabinet ventilation or forced air cooling is required if operating consistently above 40 deg C.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation and Commissioning Notes\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe V1022.00-2 requires a low-impedance protective earth (PE) connection directly to the chassis using the designated M4 screw terminal. Use a star washer to penetrate paint or anodization. The PE conductor cross-section must match the power input conductors (min 0.75 mm2 \/ 18 AWG).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClearance for Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum clearance of 80 mm above and below the drive to ensure proper convection cooling, as specified in the mechanical dimensions. Do not obstruct the top or bottom vent slots. If mounting multiple drives side-by-side, verify the cabinet ambient temperature does not exceed the derating curve limits.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMotor power cables (U\/V\/W) and encoder cables must be shielded. Terminate the shield braid on both ends using the provided cable clamps or EMC glands to ensure a 360-degree low-inductance connection to the drive chassis and the motor housing. This minimizes EMI and prevents feedback errors.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-in Module Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways disconnect the 24 VDC control voltage and the main power before inserting or removing plug-in modules. Electrostatic discharge (ESD) protection is mandatory; handle modules only by their plastic housings or use a grounded wrist strap.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086374265195,"sku":"V1022.00-2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/v1022.00-2-v0j3dz3gnmr.png?v=1776138023","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-v1022-00-2-acopos-1022-single-axis-servo-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}