{"product_id":"b-r-x20ao4622-x20-system-4-channel-analogue-output-module","title":"Module de sortie analogique 4 canaux système X20AO4622 B\u0026R X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AO4622 (X20AO4622)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 4-channel analogue output module within the flagship X20 system, designed to provide seamless control for actuators, valves, and variable frequency drives. As part of a universal automation solution, this module sets a new industrial standard for high-density I\/O integration, offering a more economical and secure footprint for machine and system manufacturing. In demanding sectors such as plastics processing, food and beverage, and precision CNC manufacturing, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AO4622\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures superior signal accuracy and stability. Its modular architecture allows for \"hot-swapping\" on the X20 backplane, significantly reducing maintenance-related downtime and providing the scalability required for complex, distributed automation architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AO4622\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is built for versatility, providing four independent analogue outputs capable of standard industrial signal ranges (typically 0-10 V or 4-20 mA, depending on configuration). The module interfaces directly with the X20 system bus, benefitting from internal electrical isolation to protect the central processing unit from field-side electrical interference. Its design emphasizes reliability, featuring integrated short-circuit protection and diagnostic capabilities that report channel-specific errors back to the controller. The ultra-slim form factor of the X20 series allows this 4-channel module to occupy minimal DIN rail space, making it ideal for compact control cabinets where high I\/O density is a critical requirement.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20AO4622\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalogue Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit or higher (Application dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (Field to Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail Mounting \/ X20 Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort circuit, Overload, Status LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95 percent, no condensation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the X20AO4622 compatible with all X20 bus controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the X20AO4622 is designed to be fully compatible with the universal X20 system bus. It can be used with X20 CPUs as well as X20 bus receivers for distributed I\/O stations over POWERLINK, CANopen, or EtherCAT.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle a short circuit on an output channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features integrated short-circuit protection. If a fault is detected on a specific channel, the module will limit the current and trigger a diagnostic bit in the control software, allowing the system to alert the operator without damaging the module hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate power supply for the outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTypically, the X20 system provides power via the internal I\/O bus (I\/O supply). However, depending on the total load of your X20 slice, an additional X20 potential supply module (such as an X20PS) may be required to ensure sufficient current for all 4 analogue channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace this module while the system is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, one of the core advantages of the X20 system is its modularity. The electronic module can be removed from the terminal block and backplane without disconnecting the field wiring or powering down the entire station, facilitating rapid maintenance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor high-precision analogue control, always use twisted-pair shielded cables. The cable shield should be grounded at the X20 system's grounding rail using the appropriate shield terminals. This is vital to prevent electromagnetic interference (EMI) from distorting the 0-10 V or 4-20 mA signals, especially in environments with heavy motor noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane and Terminal Block Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore inserting the X20AO4622, ensure the X20 terminal block and bus module are correctly snapped onto the 35 mm DIN rail. Misalignment can lead to bent pins on the internal bus connector. Ensure the module \"clicks\" firmly into place to guarantee a reliable connection to the local I\/O bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Consideration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn high-density installations where multiple analogue modules are mounted side-by-side, ensure the cabinet has adequate ventilation. While the X20 series is designed for 55 deg C ambient operation, maintaining a cooler environment will extend the lifespan of the precision digital-to-analogue converters (DAC) within the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53102134296939,"sku":"X20A04622","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20a04622-ubfks5ctcbz.png?v=1776138117","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20ao4622-x20-system-4-channel-analogue-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}