{"product_id":"b-r-x20bb81-b-r-x20-bus-base-module","title":"Module de base bus B\u0026R X20BB81","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eX20BB81 (X20BB81)\u003c\/strong\u003e is a foundational bus base module designed for the B\u0026amp;R X20 system architecture. This component serves as the physical and electrical backbone for decentralized I\/O configurations, featuring one dedicated expansion slot to facilitate system scalability. By providing the mechanical interface and electrical connectivity for base modules (such as BC or HB controllers), add-on modules (IF or HB), and supply modules, the X20BB81 is essential for maintaining a structured and reliable control cabinet layout. Its integration effectively minimizes installation complexity and supports rapid maintenance cycles in high-availability industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe X20BB81 is engineered to support the modularity inherent in the X20 system. The base module serves as a carrier for the various I\/O and communication electronics, routing power and data signals via the internal X20 backplane bus. The included expansion slot allows for the flexible addition of interface or auxiliary power modules, providing system integrators the ability to tailor hardware functionality to specific process needs without modifying the core wiring structure.\u003c\/p\u003e\n\u003cp\u003eThe unit is delivered with both left and right end cover plates, ensuring a completed mechanical assembly and protection against environmental ingress. This modular approach allows for seamless hot-swapping and maintenance, as the bus base remains fixed on the DIN rail while the electronic modules can be serviced independently.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20BB81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModule Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eBus base module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eComponents Supported\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eBase modules, Add-on modules, Supply modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eLeft and right end cover plates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific modules can be mounted on the X20BB81?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe X20BB81 is compatible with a wide range of B\u0026amp;R X20 components, including base modules (e.g., bus controllers), add-on interface modules, and various supply modules required for system power distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the end cover plates required for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the end cover plates are necessary for both mechanical stability and to provide the required IP rating for the terminal assembly, ensuring electrical components are protected from dust and debris.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to replace the electronic module without removing the bus base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the X20 system is designed so that the electronic modules can be removed from the bus base without disturbing the field wiring or the bus base itself, which significantly reduces downtime during routine maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the X20BB81 provide power to the modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe bus base acts as a distribution manifold for the power supplied by the X20 power supply modules. It directs the necessary voltages to the mounted base or add-on modules to ensure stable operation.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Mechanical Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Ensure the DIN rail is securely mounted and leveled within the cabinet. Snap the X20BB81 onto the rail until an audible click is heard, confirming the latch is engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Alignment:\u003c\/strong\u003e When inserting base or add-on modules, ensure they are perfectly aligned with the guide rails on the X20BB81. Do not use excessive force; the connector pins should engage smoothly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Cover Installation:\u003c\/strong\u003e Always attach the provided end cover plates after the final module is installed. These plates prevent lateral movement of the modules on the DIN rail and provide the necessary physical protection for the backplane contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e For applications involving high-vibration equipment, ensure the locking mechanisms on the module housing are fully engaged and consider the use of end clamps on the DIN rail to restrict lateral shifting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eX20BB81 (X20BB81)\u003c\/strong\u003e is a foundational bus base module designed for the B\u0026amp;R X20 system architecture. This component serves as the physical and electrical backbone for decentralized I\/O configurations, featuring one dedicated expansion slot to facilitate system scalability. By providing the mechanical interface and electrical connectivity for base modules (such as BC or HB controllers), add-on modules (IF or HB), and supply modules, the X20BB81 is essential for maintaining a structured and reliable control cabinet layout. Its integration effectively minimizes installation complexity and supports rapid maintenance cycles in high-availability industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe X20BB81 is engineered to support the modularity inherent in the X20 system. The base module serves as a carrier for the various I\/O and communication electronics, routing power and data signals via the internal X20 backplane bus. The included expansion slot allows for the flexible addition of interface or auxiliary power modules, providing system integrators the ability to tailor hardware functionality to specific process needs without modifying the core wiring structure.\u003c\/p\u003e\n\u003cp\u003eThe unit is delivered with both left and right end cover plates, ensuring a completed mechanical assembly and protection against environmental ingress. This modular approach allows for seamless hot-swapping and maintenance, as the bus base remains fixed on the DIN rail while the electronic modules can be serviced independently.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20BB81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eX20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModule Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eBus base module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eComponents Supported\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eBase modules, Add-on modules, Supply modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eLeft and right end cover plates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific modules can be mounted on the X20BB81?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe X20BB81 is compatible with a wide range of B\u0026amp;R X20 components, including base modules (e.g., bus controllers), add-on interface modules, and various supply modules required for system power distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the end cover plates required for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the end cover plates are necessary for both mechanical stability and to provide the required IP rating for the terminal assembly, ensuring electrical components are protected from dust and debris.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to replace the electronic module without removing the bus base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the X20 system is designed so that the electronic modules can be removed from the bus base without disturbing the field wiring or the bus base itself, which significantly reduces downtime during routine maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the X20BB81 provide power to the modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe bus base acts as a distribution manifold for the power supplied by the X20 power supply modules. It directs the necessary voltages to the mounted base or add-on modules to ensure stable operation.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Mechanical Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Ensure the DIN rail is securely mounted and leveled within the cabinet. Snap the X20BB81 onto the rail until an audible click is heard, confirming the latch is engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Alignment:\u003c\/strong\u003e When inserting base or add-on modules, ensure they are perfectly aligned with the guide rails on the X20BB81. Do not use excessive force; the connector pins should engage smoothly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Cover Installation:\u003c\/strong\u003e Always attach the provided end cover plates after the final module is installed. These plates prevent lateral movement of the modules on the DIN rail and provide the necessary physical protection for the backplane contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e For applications involving high-vibration equipment, ensure the locking mechanisms on the module housing are fully engaged and consider the use of end clamps on the DIN rail to restrict lateral shifting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086368596331,"sku":"X20BB81","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bb81-t2ds4flq3vu.png?v=1776138137","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20bb81-b-r-x20-bus-base-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}