{"product_id":"b-r-x20cp0410-compact-s-cpu-system-control-module","title":"Module de contrôle système CPU Compact-S X20CP0410 B\u0026R","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview and Strategic Value\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP0410 (X20 CP 0410)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency entry point into the B\u0026amp;R\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact-S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller class, bridging the gap between cost-effectiveness and industrial-grade performance. Engineered with an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eARM Cortex-A9\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessor architecture, this PLC is designed for decentralized control tasks and space-critical applications in sectors such as high-end packaging, renewable energy monitoring, and precision machine building. By integrating an independent I\/O processor that handles data points in the background, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP0410\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that the main CPU cycle remains dedicated to complex logic execution, significantly reducing jitter and enhancing system stability. Its fanless design and wide operating temperature range make it a cornerstone for reducing maintenance overhead in mission-critical environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Architecture and Memory Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP0410\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for long-term reliability and rapid data processing. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e128 MB DDR3 SDRAM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor demanding application code and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 kB of FRAM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor remanent variables. Unlike traditional battery-backed solutions, the FRAM technology ensures data retention for over 10 years without power, protecting vital machine states during unexpected outages.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller comes standard with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1x Ethernet\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2x USB\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1x X2X Link\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor seamless expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTiming Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a typical instruction cycle time of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.0446 microseconds\u003c\/strong\u003e, it handles logic operations with exceptional speed for its class.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Ethernet interface (IF2) is electrically isolated from the PLC internal logic and other interfaces, preventing ground loops and protecting the CPU core from external electrical surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetailed Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eX20CP0410\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R (Automation Studio Compatible)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eARM Cortex-A9\u003c\/strong\u003e (166 MHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 MB DDR3 RAM \/ 8 kB FRAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e2.2 W\u003c\/strong\u003e (High efficiency)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShortest Cycle Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e4 ms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReal-Time Clock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRetention up to 1000 hours (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFanless\u003c\/strong\u003e (Natural convection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 60 Celsius (Horizontal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard X20 System width\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1.0 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Logic \u0026amp; Maintenance FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the status indicators assist in onsite troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP0410\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLED indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor CPU function and Ethernet status. A solid green CPU LED indicates normal operation, while specific blink patterns signal system exceptions, allowing technicians to diagnose state errors without a programming laptop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the thermal considerations for vertical vs. horizontal mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to the fanless convection design, the module is rated up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e60 Celsius\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein horizontal orientation. When mounted vertically, the ambient temperature limit is reduced to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 Celsius\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure proper heat dissipation across the internal components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the Real-Time Clock (RTC) survive a long weekend power down?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The RTC offers a minimum retention of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e300 hours\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(approximately 12 days) and a typical retention of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1000 hours\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat 25 Celsius. This ensures that timestamps for logs and alarms remain accurate through standard plant shutdowns.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX2X Link Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting expansion modules via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX2X Link\u003c\/strong\u003e, ensure the total current consumption of the I\/O modules does not exceed the supply limit of the controller. For large-scale I\/O trees, use an additional bus controller or power supply module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUSB Port Usage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2x USB 2.0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eports are designed for firmware updates and data logging. To prevent mechanical strain on the ports in high-vibration environments, use industrial-grade, low-profile USB drives or secured cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem temperature can be monitored via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esoftware register\u003c\/strong\u003e. It is recommended to map this register to your HMI to trigger a preventive cooling alert before the CPU reaches its thermal cutoff.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP0410\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere heat buildup is a concern. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.2 W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower draw is among the lowest in the ARM-based PLC category, minimizing the thermal footprint within the enclosure. Furthermore, its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R ID code 0xE94F\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures instant recognition within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAutomation Studio\u003c\/strong\u003e, streamlining the hardware configuration process and reducing time-to-market for machine OEMs.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53102138655083,"sku":"X20CP0410","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20cp0410-e2emmtndb43.png?v=1776138158","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20cp0410-compact-s-cpu-system-control-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}