{"product_id":"b-r-x20cp1583-x20-system-master-controller-cpu-module","title":"B\u0026R X20CP1583 Module CPU contrôleur maître système X20","description":"\u003ch3\u003eProcessing Performance and Industrial Automation Role\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP1583 (X20CP1583)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity industrial embedded controller designed to serve as the master processing nucleus for complex B\u0026amp;R X20 automation architectures. Tailored for heavy-duty process control loop execution, high-precision multi-axis motion synchronization, and real-time data acquisition in demanding sectors like automotive assembly, petrochemical processing, and renewable energy monitoring, this CPU handles concurrent computing tasks with high determinism. Its fan-free cooling design eliminates mechanical failure risks, preventing downtime caused by airborne particulate infiltration. Integrating this robust controller into your central control cabinet establishes a high-availability automation topology that minimizes cyclic execution jitter, guarantees low-latency network scanning, and shields production operations from unmanaged system halts.\u003c\/p\u003e\n\u003ch3\u003eNetwork Architecture and Hardware Diagnostics\u003c\/h3\u003e\n\u003cp\u003eCarrying the official B\u0026amp;R ID code 0xD45B, this master controller is driven by a high-efficiency 333 MHz clock frequency processor core. The hardware offers an expansive communication matrix, hosting one RS232 serial interface for legacy field device links, one standard Ethernet port for enterprise network integration, two USB slots for local system diagnostics, and an integrated X2X Link master bus to manage local I\/O slice extensions. Real-time synchronization of remote drives and distributed I\/O blocks is managed through an onboard real-time Ethernet POWERLINK (V1\/V2) connection. System health status is monitored continuously via an integrated LED array, providing field engineers with immediate visual metrics for core CPU function, overtemperature states, Ethernet links, POWERLINK loops, CompactFlash card access, and internal backup battery levels.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Performance Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineered Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20CP1583\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System CPU Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R ID Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0xD45B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Clock Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e333 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x RS232, 1x Ethernet, 1x POWERLINK V1\/V2, 2x USB, 1x X2X Link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.2 W (Base load without interface module and USB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFan-free convection thermal management\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Subsystem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated CompactFlash slot for system software and application images\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Infrastructure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLocal LEDs for CPU, Temp, Eth, Powerlink, CF, and Battery status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Humidity Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAustria\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGross Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg (Enclosed in multi-layer electro-static discharge shielding)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Integration FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be checked if the local overtemperature LED indicator activates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn active overtemperature indicator means the internal CPU silicon has exceeded its engineered thermal boundaries. Immediately inspect the enclosure to confirm that ventilation grilles are unobstructed, check that the fan-free convective fins on the CPU housing are clear of dust insulation, and verify that adjacent heat-generating devices comply with clearance specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this CPU manage program backups and operating system runtime execution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe X20CP1583 relies on an industrial CompactFlash card as its primary non-volatile boot medium. The B\u0026amp;R Automation Runtime operating system, hardware configurations, and compiled application code are stored entirely on this card. This architecture permits immediate, card-swap hardware replacement without requiring a separate field programming computer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the baseline 8.2 W power consumption change depending on the hardware configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 8.2 W rating defines the base electrical load of the processor and core backplane logic lines. Adding communication interface modules to the auxiliary slots or connecting high-draw field diagnostics to the USB ports will increase total power demand, which must be factored into your central 24 VDC system power supply budget.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Deployment Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompactFlash Storage Handling Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CompactFlash card interface is sensitive to electrostatic discharge (ESD) and files can become corrupted if handled incorrectly. Always isolate the main 24 VDC power supply from the CPU before inserting or removing the storage card. Ensure the card is partition-formatted via B\u0026amp;R Automation Studio to guarantee correct boot sequence execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOWERLINK Cable Shielding and Grounding Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed real-time POWERLINK communications are susceptible to high-frequency electromagnetic interference (EMI) generated by neighboring variable frequency drives (VFDs). You must utilize Category 5e (or higher) double-shielded industrial Ethernet cables. Ground the braided copper shielding completely to the metallic DIN rail using low-impedance grounding clips at the enclosure entry point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Rail Installation Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMount the CPU module vertically onto standard clean, corrosion-free DIN rails. Verify that the integrated backplane grounding clips establish a tight, metal-on-metal connection with the grounded mounting plate, providing an absolute path to functional earth for the entire connected X20 I\/O module segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370398571,"sku":"X20CP1583","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20cp1583-0mfa3kdgcve.png?v=1776138163","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20cp1583-x20-system-master-controller-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}