{"product_id":"b-r-x20cs1070-x20-series-can-bus-communication-module","title":"Module de communication bus CAN B\u0026R X20CS1070 X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CS1070 (X20CS1070)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance communication electronics module within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R X20 System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elineup, serving as a dedicated gateway for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCAN bus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegration. Engineered for deterministic data exchange in complex industrial networks, this module allows X20 PLC systems to interface seamlessly with CAN-based peripherals such as variable frequency drives (VFDs), specialized sensors, and third-party controllers. Supporting transfer rates up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 Mbit\/s\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CS1070\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis vital for high-speed motion control and real-time process monitoring. Its compact 12.5 mm design, combined with integrated diagnostic indicators and a software-switchable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eterminating resistor\u003c\/strong\u003e, ensures a streamlined installation process while maintaining the highest levels of network stability.\u003c\/p\u003e\n\u003ch3\u003eNetwork Architecture and Communication Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CS1070\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a robust communication bridge, providing the physical and logical layer necessary for reliable CAN networking in harsh EMI environments.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports standard CAN transmission rates from low-speed long-distance runs up to a maximum of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 Mbit\/s\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor local high-speed synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an internal terminating resistor that can be activated via software, eliminating the need for external resistors at the end of the bus line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Network Reach:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of managing network segments with a maximum distance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1000 m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(at reduced bitrates), making it suitable for large-scale factory floor deployments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour dedicated LEDs provide instant feedback on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eData Transfer\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTerminating Resistor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estatus,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOperating Status\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModule Status\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eX20CS1070\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Electronics Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eID Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0x1FD1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 1 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminating Resistor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated (Software-switchable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRequired: 12-pin X20TB12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I activate the internal terminating resistor in the X20CS1070?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe terminating resistor is software-controlled within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R Automation Studio\u003c\/strong\u003e. In the module's hardware configuration, you can toggle the resistor \"ON\" if the module is positioned at the physical end of the CAN network segment, ensuring signal integrity by preventing reflections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 0x1FD1 ID code?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0x1FD1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eID code is the unique electronic identifier for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CS1070\u003c\/strong\u003e. When the X20 system performs its power-on self-test (POST), the bus controller verifies this ID to ensure the physical hardware matches the software project configuration, preventing communication mismatches.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the X20CS1070 for CANopen applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module manages the physical and data link layers of the CAN bus, higher-level protocols like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCANopen\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare handled via the B\u0026amp;R software libraries. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CS1070\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the deterministic hardware foundation required for robust CANopen master or slave functionality.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for Long Distances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor runs approaching the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1000 m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elimit, use high-quality twisted-pair cabling with a cross-section of at least 0.5 mm squared. Ensure the transfer rate is lowered in Automation Studio to match the physical cable length (e.g., 50 kbit\/s for 1000 m).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis electronics module requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-pin X20TB12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block. Ensure that the shield of the CAN cable is connected to the functional ground (FE) at the terminal block to divert high-frequency interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Best Practices:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent ground loops across long CAN segments, ensure that the potential equalization between the different network nodes is addressed. The X20 system's internal bus isolation helps, but a common reference ground for the CAN transceiver is recommended.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CS1070\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for maximum uptime in mission-critical systems. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4.0 kg\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshipping weight (reflecting the protective bulk packaging) underscores the industrial-grade nature of B\u0026amp;R's communication hardware. The module's ability to provide real-time status via LEDs—specifically the \"Terminating Resistor\" LED—allows for rapid visual audits of network topology without opening software diagnostics. Its wide operating temperature and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotection ensure it thrives in the heat and vibration common to cabinet-mounted industrial automation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086378590571,"sku":"X20CS1070","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/X20CS1070-y0ftsuuwdt4.png?v=1776064798","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20cs1070-x20-series-can-bus-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}