{"product_id":"b-r-x20hb8815-x20-system-powerlink-to-tcp-ip-gateway-module","title":"B\u0026R X20HB8815 Module passerelle POWERLINK vers TCP\/IP système X20","description":"\u003ch3\u003eTechnical Description and Gateway Routing Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20HB8815 (X20HB8815)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an industrial-grade communication gateway designed for the modular B\u0026amp;R X20 System platform. This module functions as a highly efficient POWERLINK controlled node that bridges deterministic, real-time industrial Ethernet loops with standard non-real-time TCP\/IP network infrastructures. It is engineered for complex automation applications—such as large-scale automotive assembly lines, municipal water distribution systems, and power plant control architectures—where field-level sensor and drive data must be routed transparently to higher-level SCADA, MES, or enterprise networks. The underlying hardware architecture includes an integrated expansion interface featuring up to two dedicated slots for hub expansion modules, allowing plant engineers to scale local network topologies dynamically without adding separate standalone switch hardware.\u003c\/p\u003e\n\u003ch3\u003eNetwork Interface and Electrical Architecture\u003c\/h3\u003e\n\u003cp\u003eThe physical interface of the gateway features two shielded RJ45 ports that support standard segment line lengths up to a maximum of 100 meters between communication stations. The module manages two distinct network layers through these ports: a high-speed, real-time POWERLINK channel operating at a fixed transfer rate of 100 Mbit\/s, and a standard TCP\/IP channel with auto-negotiating 10\/100 Mbit\/s capabilities. Built for continuous operation inside high-density electrical enclosures, the module maintains a low thermal signature by drawing a maximum power consumption of 2 W from the backplane bus. Onboard diagnostic arrays feature clear LED status indicators that provide real-time visual updates for overall module health status and active bus communication function.\u003c\/p\u003e\n\u003ch3\u003ePerformance and Network Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineered Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20HB8815\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 System Communication Gateway\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNode Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOWERLINK Controlled Node\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2 slots for hub expansion modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x Shielded RJ45 ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Segment Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 m between 2 stations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOWERLINK Transfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTCP\/IP Transfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 \/ 100 Mbit\/s (Auto-negotiating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Diagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnboard LEDs for Module Status and Bus Function\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAustria\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGross Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg (Enclosed in electro-static discharge shielding)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Integration FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary architectural purpose of deploying the X20HB8815 gateway?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module acts as a managed firewall and data bridge between your real-time machine control loop (POWERLINK) and your plant network (TCP\/IP). It permits parameters, diagnostic traces, and operational data to be extracted by external software without allowing standard network broadcast storms to disrupt the microsecond-level synchronization of the machine drives.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the two expansion slots on the gateway function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe two integrated expansion slots accommodate auxiliary X20 hub expansion modules (such as fiber optic interfaces). This lets you customize the physical media types and port density directly on the gateway node, bypassing the need for an external standalone industrial switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this gateway function as a POWERLINK Managing Node (Master)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The X20HB8815 is strictly designated as a POWERLINK Controlled Node (Slave). It requires a primary X20 CPU or an advanced master controller to manage the cyclic network scheduling across the local bus segment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Deployment Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Cable Routing Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause POWERLINK communicates at high speeds, you must use industrial-grade Category 5e (or higher) double-shielded twisted-pair (S\/FTP) cabling. Ensure the outer metal braid of the RJ45 connector makes clean contact with the shielded socket of the X20HB8815 to provide a low-impedance path to ground, preventing electromagnetic interference (EMI) from corrupting the real-time data packets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Module Installation Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrior to inserting or removing hub expansion modules into the auxiliary slots of the X20HB8815, completely isolate the 24 VDC power supply to the local X20 rack. Modifying the hardware layout while the backplane is powered can cause micro-arcing on the connector pins, which can permanently damage the internal routing logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Segmentation Layout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen configuring the TCP\/IP interface for SCADA or MES data access, map out your IP address allocations carefully in B\u0026amp;R Automation Studio. Keep your real-time process image variables separated from heavy asynchronous data transfers to maintain low jitter and deterministic performance across the primary POWERLINK network segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086370791787,"sku":"X20HB8815","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20hb8815-ncfcbmq2kpu.png?v=1776138201","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20hb8815-x20-system-powerlink-to-tcp-ip-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}