{"product_id":"b-r-x20if1072-x20-can-bus-interface-module","title":"B\u0026R X20IF1072 Module d'interface bus CAN X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20IF1072 (X20IF1072)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated CAN bus interface module designed for the B\u0026amp;R X20 system, enabling high-speed deterministic communication with a wide array of industrial field devices. Equipped with the industry-standard SJA 1000 controller, this module allows X20 PLCs to interface seamlessly with CAN-based sensors, actuators, and motor drives. It is particularly effective in mobile automation, specialized vehicle control, and distributed industrial networks where robust, long-distance communication is required. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20IF1072\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures high data integrity across distances up to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1000$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003em, making it a critical component for large-scale assembly lines and process automation skids.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module architecture is optimized for high-speed serial data exchange and physical layer reliability.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSJA 1000 Controller:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes a high-performance standalone CAN controller to manage bus arbitration and error handling, offloading these tasks from the system CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a built-in terminating resistor that can be activated to ensure proper signal impedance, eliminating the need for external resistor blocks at the end of the bus line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes a 5-pin male multipoint connector for secure and standardized wiring of the CAN High, CAN Low, and Ground lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Visibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes status LEDs for real-time monitoring of the module health, active data transfer, and the state of the internal terminating resistor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20IF1072\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSJA 1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Transfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Cable Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-pin male multipoint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.79 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminating Resistor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum speed I can achieve with the X20IF1072?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports transfer rates up to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMbit\/s. However, the maximum speed is inversely proportional to the cable length; for example,\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eMbit\/s is typically limited to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$40$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emeters, while longer distances like\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1000$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emeters require lower baud rates (e.g.,\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$50$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ekbit\/s).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I enable the integrated terminating resistor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe terminating resistor is integrated within the module hardware and can be monitored via the status LED. Configuration is typically handled through the B\u0026amp;R Automation Studio software environment during the hardware setup phase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used for CANopen communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, since CANopen is a high-level protocol based on the CAN physical layer, the X20IF1072 hardware can support CANopen master or slave configurations when paired with the appropriate B\u0026amp;R software libraries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation and CAN Network Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Topology and Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA CAN network must be terminated with\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$120$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eat both physical ends of the bus. If the X20IF1072 is the first or last node in the network, ensure the internal termination is active. Failure to terminate correctly will result in signal reflections and communication \"Bus Off\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse high-quality shielded twisted-pair cable specifically rated for CAN bus (characteristic impedance of\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$120$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e). The shield should be connected to the functional ground at a single point to prevent ground loops while protecting the data lines from EMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGround Potential:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the ground potential between all CAN nodes is equalized. Significant potential differences between nodes can damage the SJA 1000 transceiver or cause intermittent data corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaud Rate Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll nodes on the CAN segment must be configured to the exact same baud rate and sample point. Use the \"Module Status\" and \"Data Transfer\" LEDs to verify that the module has successfully entered the \"Pre-operational\" or \"Operational\" state without error flags.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086375903595,"sku":"X20IF1072","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20if1072-yjg2rlr1ryn.png?v=1776138206","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20if1072-x20-can-bus-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}