{"product_id":"b-r-x20if10e3-1-x20-communication-interface-module","title":"Module interface de communication B\u0026R X20IF10E3-1 X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20IF10E3-1 (X20IF10E31)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance communication interface module engineered for the B\u0026amp;R X20 system to facilitate seamless data exchange between industrial networks and local I\/O backplanes. Designed to enhance the connectivity of X20 PLCs and industrial PCs, this module acts as a dedicated gateway, offloading communication tasks from the main CPU to ensure deterministic performance in complex automation environments. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20IF10E3-1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely utilized in large-scale distributed control systems (DCS), high-speed material handling, and smart manufacturing lines where real-time synchronization between disparate network nodes is a critical requirement for reducing cycle times and operational bottlenecks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis interface module is optimized for high-density integration and real-time diagnostic transparency within a standard X20 slice format.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a multi-stage LED array that provides immediate visual feedback on module health, network connectivity, and active data transfer, significantly reducing troubleshooting time during field commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Power Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates with a low power consumption profile of 2 W, minimizing the thermal load on the cabinet and ensuring stability when multiple communication modules are utilized in a single station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized X20 Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComplies with the 12.5 mm pitch architecture, allowing it to be integrated into any standard X20 system row via an X20 bus module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFieldbus Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to support robust communication protocols, providing a bridge between the internal X2X Link backplane and external fieldbus levels with high signal integrity and low jitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20IF10E3-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModule Status, Network Status, Data Transfer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware (LED) and Software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 60 deg C (Horizontal mounting)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard X20 width (12.5 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I monitor the data transfer status of the X20IF10E3-1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features a dedicated \"Data Transfer\" LED on the front panel. Rapid flashing indicates active communication, while the status can also be monitored in real-time through the B\u0026amp;R Automation Studio diagnostic environment via the system's I\/O mapping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it necessary to use a specific bus module with the X20IF10E3-1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, this module requires a compatible X20 bus module (typically X20BM11) to interface with the X2X Link backplane. The bus module must be ordered separately as it defines the electrical connection to the adjacent slices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the X20IF10E3-1 be hot-swapped during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the X20 system supports modularity, it is recommended to power down the station or ensure the specific bus segment is inactive before removing the interface module to prevent communication timeouts or potential damage to the active network.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation and Network Maintenance\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Shielding and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure error-free data transmission at high baud rates, the communication cables must be properly shielded. The shield should be connected to the functional ground through the X20 system's grounding rail to mitigate the effects of high-frequency interference from nearby variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore operation, the module must be correctly configured in the hardware tree of Automation Studio. Ensure the firmware version of the X20IF10E3-1 is compatible with the CPU's operating system version to avoid \"Invalid Module\" errors during the boot sequence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the module only consumes 2 W, ensure that the ventilation slots on the top and bottom of the X20 housing are not obstructed. In environments where the ambient temperature exceeds 50 deg C, horizontal mounting is mandatory to utilize natural convection for heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic LED Logic:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Status (Green):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSteady indicates normal operation; flashing indicates a configuration mismatch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Status (Red\/Yellow):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates physical layer errors or logical connection failures with the external network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086376329579,"sku":"X20IF10E3-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20if10e3-1-gfkuztz1mm0.png?v=1776138209","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20if10e3-1-x20-communication-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}