{"product_id":"b-r-x20ps3300-x20-system-power-supply-module","title":"Module d'alimentation système B\u0026R X20PS3300 X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS3300 (X20PS3300)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency power supply module designed to provide the necessary internal logic and I\/O power for the B\u0026amp;R X20 System backplane. This module functions as a centralized power feed, converting an external 24 VDC input into the stabilized voltages required for downstream I\/O slices and communication modules. Engineered for reliability in mission-critical industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20PS3300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential component for modular control systems in automotive manufacturing, pharmaceutical processing, and renewable energy sectors. Its integrated diagnostic features and compact 12.5 mm width allow for maximum power density and system availability within standardized control cabinet layouts.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe power architecture of the X20PS3300 is optimized for safety and real-time monitoring within the X20 ecosystem.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated Power Feed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts a nominal 24 VDC input with a wide tolerance range (20.4 to 28.8 VDC), ensuring stable operation even during voltage fluctuations in the primary factory power grid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a built-in, non-replaceable fuse that protects the internal system bus from overcurrent conditions and short circuits originating on the field side.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with dedicated LED indicators for \"Overload,\" \"Operating State,\" and \"Module Status,\" allowing maintenance personnel to identify power distribution issues immediately without external tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Thermal Impact:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for high efficiency with a maximum input current of 0.7 A, minimizing heat dissipation and allowing for high-density installation alongside sensitive analog modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20PS3300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R ID Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0x1BC0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (-15% \/ +20%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Fuse (Internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, Operating State, Module Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary role of the X20PS3300 compared to a bus controller's power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile bus controllers have integrated power supplies for small configurations, the X20PS3300 is used to refresh the power on the X2X Link bus when the total power consumption of the connected I\/O modules exceeds the controller's capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I do if the \"Overload\" LED is active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn active Overload LED indicates that the total current draw from the downstream modules is exceeding the X20PS3300's output rating. You must recalculate the power budget in Automation Studio and potentially add another X20PS3300 module to split the power segments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the fuse replaceable if it blows?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the integrated fuse is a safety component designed to protect the backplane and is not user-replaceable. If the fuse is blown due to a catastrophic failure, the module must be replaced to ensure continued system protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Installation and Power Management Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Budgeting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore installation, use B\u0026amp;R Automation Studio to verify the power consumption of your I\/O station. Ensure that the X20PS3300 is placed at a point in the rack where it can sufficiently supply all subsequent modules on the X2X Link without triggering the overload protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting the external 24 VDC supply, use high-quality industrial wire with ferrules. Ensure the polarity is correct; although the X20 system is robust, reverse polarity can cause stress on protective components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSegment Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe X20PS3300 can be used to create separate power segments for different types of I\/O (e.g., separating digital and analog power). This prevents electrical noise from high-frequency switching on digital lines from affecting sensitive analog measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Consideration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn environments with ambient temperatures consistently above 50 deg C, ensure there is at least 10 mm of clearance above and below the X20 rack to facilitate natural convection cooling, as power supply modules are generally the warmest components in a station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086375969131,"sku":"X20PS3300","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ps3300-hyw5vfxfl1p.png?v=1776138216","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20ps3300-x20-system-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}